Introduction and rationale
Benign airway stenosis or malacia is a frequent complication of lung transplantation occurring in 4-24% of patients, most often occurring two to nine months post-transplant. Initial therapeutic approach consists of conservative endobronchial treatment with recurrent balloon dilatation, radial incision, and electro cautery. For severe case of recurrent stenosis or malacia, airway stent placement can be considered. Different types of airway stent exist, for instance self-extendable metallic stent (SEMS), silicone stent and biodegradable airway stent. Conventional airway stents (SEMS, silicone) are associated with complications as granulation tissue and recurrent infections and can be difficult to remove. Newly developed biodegrabale stents are made of polydioxanone and disintegrate after a period of time are thought to have less side effects, and has been standard of care for the last few years. A sub selection of patients have been treated with conventional stent before treated with biodegradable stent.
Research question
- To assess the efficacy and efficiency of biodegradable airway stent.
- Compare occurrence of adverse events such as infection, dislocation, in stent granulation and difficulty of removal to conventional metallic or silicone stents.
- Asses if biodegradable stent lead to improvement of lung function.
- Assessment of the life span of biodegradable stents.
Visão geral do estudo
Status
Intervenção / Tratamento
Descrição detalhada
- Background Recurrent airway stenosis or malacia can be treated with airway stents. Conventional airway stents, for instance self-extendable metallic stent (SEMS) and silicone stent are associated with adverse events as recurrent infection or granulation tissue and can be difficult to remove because of in stent-granulation. Therefore they are used with restraint for benign airway problems. Biodegradable stents are made of polydioxanone and disintegrate after a period of time. They are thought to be well tolerated and associated with less adverse events compared to traditional airway stent and have been used as standard care for multiple years.
Main research question
- To assess the efficacy and efficiency of biodegradable airway stent
- Compare occurrence of adverse events such as infection, dislocation, in stent granulation and difficulty of removal to conventional metallic or silicone stents.
- Asses if biodegradable stent lead to improvement of lung function.
- Assessment of the life span of biodegradable stents.
- Design (including population, confounders/outcomes) Retrospective cohort study of patients with airway stenosis or malacia treated with biodegradable airway stent from 2019 in the UMCG and Amsterdam UMC.
Expected results
- Less adverse events, hospital admittance and need for bronchoscopic interventions compared to patients treated with conventional stents. No complications associated with removal of stents.
- Life span around 4 months
Tipo de estudo
Inscrição (Real)
Estágio
- Não aplicável
Contactos e Locais
Locais de estudo
-
-
-
Amsterdam, Holanda
- AMC
-
Groningen, Holanda
- UMCG
-
-
Critérios de participação
Critérios de elegibilidade
Idades elegíveis para estudo
Aceita Voluntários Saudáveis
Gêneros Elegíveis para o Estudo
Descrição
Inclusion Criteria:
- Patients who underwent a lung transplantation and developed airway stenosis or malacia with airway stent requirement
Exclusion Criteria:
- No
Plano de estudo
Como o estudo é projetado?
Detalhes do projeto
- Finalidade Principal: Tratamento
- Alocação: N / D
- Modelo Intervencional: Atribuição de grupo único
- Mascaramento: Nenhum (rótulo aberto)
Armas e Intervenções
Grupo de Participantes / Braço |
Intervenção / Tratamento |
|---|---|
|
Experimental: Biodegradable stent treatment group
|
Bronchoscopic placement of biodegradable stent in patients with airway complications after lung transplant
|
O que o estudo está medindo?
Medidas de resultados primários
Medida de resultado |
Descrição da medida |
Prazo |
|---|---|---|
|
Adverse events
Prazo: 4 months after placement
|
Adverse events associated with airway stents
|
4 months after placement
|
Medidas de resultados secundários
Medida de resultado |
Descrição da medida |
Prazo |
|---|---|---|
|
Change in FEV1
Prazo: 1 week post placement
|
Change in FEV1 measured by spirometry pre and post stent placement
|
1 week post placement
|
|
Change in FVC
Prazo: 1 week post placement
|
Change in FVC measured by spirometry pre and post stent placement
|
1 week post placement
|
|
Time to need for new stent placement
Prazo: 6 months after placement
|
Endurance and life span of biodegradable stent measured by time to need for new stent placement
|
6 months after placement
|
Colaboradores e Investigadores
Patrocinador
Colaboradores
Investigadores
- Investigador principal: Dirk-Jan Slebos, MD, PhD, UMCG
Datas de registro do estudo
Datas Principais do Estudo
Início do estudo (Real)
Conclusão Primária (Real)
Conclusão do estudo (Real)
Datas de inscrição no estudo
Enviado pela primeira vez
Enviado pela primeira vez que atendeu aos critérios de CQ
Primeira postagem (Real)
Atualizações de registro de estudo
Última Atualização Postada (Real)
Última atualização enviada que atendeu aos critérios de controle de qualidade
Última verificação
Mais Informações
Termos relacionados a este estudo
Outros números de identificação do estudo
- 20220075
Plano para dados de participantes individuais (IPD)
Planeja compartilhar dados de participantes individuais (IPD)?
Informações sobre medicamentos e dispositivos, documentos de estudo
Estuda um medicamento regulamentado pela FDA dos EUA
Estuda um produto de dispositivo regulamentado pela FDA dos EUA
Essas informações foram obtidas diretamente do site clinicaltrials.gov sem nenhuma alteração. Se você tiver alguma solicitação para alterar, remover ou atualizar os detalhes do seu estudo, entre em contato com register@clinicaltrials.gov. Assim que uma alteração for implementada em clinicaltrials.gov, ela também será atualizada automaticamente em nosso site .