Triple-Scan Protocol to Assess Passivity
Triple-Scan Protocol for Evaluating Passivity of Complete-Arch Implant-Supported Fixed Prostheses: A Randomized Clinical Study
調査の概要
状態
研究の種類
入学 (実際)
段階
- 適用できない
連絡先と場所
研究場所
-
-
-
Al Mansurah、エジプト
- Alaa Mohamed Barakat Elazaly
-
-
参加基準
適格基準
就学可能な年齢
- 大人
健康ボランティアの受け入れ
説明
Inclusion Criteria:
Reduced patient satisfaction regarding the stability and retention of conventional mandibular dentures due to mandibular ridge atrophy.
Completely edentulous maxillary and mandibular arches for at least 1 year. Sufficient bone volume for placement of four mandibular implants without the need for bone grafting.
Age between 45 and 64 years. Ability and willingness to provide informed consent and comply with study procedures.
Exclusion Criteria:
Current smoking habit. Bone metabolic diseases that may affect osseointegration. History of radiotherapy to the head and neck region within the previous 3 years.
Systemic conditions or medications that could compromise implant healing. Inability to attend follow-up visits or comply with study requirements.
研究計画
研究はどのように設計されていますか?
デザインの詳細
- 主な目的:処理
- 割り当て:ランダム化
- 介入モデル:クロスオーバー割り当て
- マスキング:独身
武器と介入
参加者グループ / アーム |
介入・治療 |
|---|---|
|
アクティブコンパレータ:Sequence A
Participants received the three impression techniques in the following order: Conventional Impression Technique Digital Impression with Nonmodified Scan Body Digital Impression with Modified Scan Body |
Conventional implant impression using impression copings and elastomeric impression material.
Digital implant impression obtained using nonmodified implant scan bodies
Digital implant impression obtained using subtractively modified implant scan bodies
|
|
アクティブコンパレータ:Sequence B
Participants received the three impression techniques in the following order: Digital Impression with Nonmodified Scan Body Digital Impression with Modified Scan Body Conventional Impression Technique |
Conventional implant impression using impression copings and elastomeric impression material.
Digital implant impression obtained using nonmodified implant scan bodies
Digital implant impression obtained using subtractively modified implant scan bodies
|
|
アクティブコンパレータ:Sequence C
Participants received the three impression techniques in the following order: Digital Impression with Modified Scan Body Conventional Impression Technique Digital Impression with Nonmodified Scan Body |
Conventional implant impression using impression copings and elastomeric impression material.
Digital implant impression obtained using nonmodified implant scan bodies
Digital implant impression obtained using subtractively modified implant scan bodies
|
この研究は何を測定していますか?
主要な結果の測定
結果測定 |
メジャーの説明 |
時間枠 |
|---|---|---|
|
Mean horizontal misfit (µm)
時間枠:Day 1
|
Mean horizontal misfit using the triple-scan protocol and STL file superimposition in software.
Results will be reported in micrometers (µm).
|
Day 1
|
|
Mean vertical misfit (µm)
時間枠:Day 1
|
Mean vertical misfit using the triple-scan protocol and STL file superimposition in software.
Results will be reported in micrometers (µm).
|
Day 1
|
協力者と研究者
スポンサー
研究記録日
主要日程の研究
研究開始 (実際)
一次修了 (実際)
研究の完了 (実際)
試験登録日
最初に提出
QC基準を満たした最初の提出物
最初の投稿 (実際)
学習記録の更新
投稿された最後の更新 (実際)
QC基準を満たした最後の更新が送信されました
最終確認日
詳しくは
本研究に関する用語
その他の研究ID番号
- R.25.09.24
医薬品およびデバイス情報、研究文書
米国FDA規制医薬品の研究
米国FDA規制機器製品の研究
この情報は、Web サイト clinicaltrials.gov から変更なしで直接取得したものです。研究の詳細を変更、削除、または更新するリクエストがある場合は、register@clinicaltrials.gov。 までご連絡ください。 clinicaltrials.gov に変更が加えられるとすぐに、ウェブサイトでも自動的に更新されます。