Triple-Scan Protocol to Assess Passivity
Triple-Scan Protocol for Evaluating Passivity of Complete-Arch Implant-Supported Fixed Prostheses: A Randomized Clinical Study
研究概览
地位
研究类型
注册 (实际的)
阶段
- 不适用
联系人和位置
学习地点
-
-
-
Al Mansurah、埃及
- Alaa Mohamed Barakat Elazaly
-
-
参与标准
资格标准
适合学习的年龄
- 成人
接受健康志愿者
描述
Inclusion Criteria:
Reduced patient satisfaction regarding the stability and retention of conventional mandibular dentures due to mandibular ridge atrophy.
Completely edentulous maxillary and mandibular arches for at least 1 year. Sufficient bone volume for placement of four mandibular implants without the need for bone grafting.
Age between 45 and 64 years. Ability and willingness to provide informed consent and comply with study procedures.
Exclusion Criteria:
Current smoking habit. Bone metabolic diseases that may affect osseointegration. History of radiotherapy to the head and neck region within the previous 3 years.
Systemic conditions or medications that could compromise implant healing. Inability to attend follow-up visits or comply with study requirements.
学习计划
研究是如何设计的?
设计细节
- 主要用途:治疗
- 分配:随机化
- 介入模型:交叉作业
- 屏蔽:单身的
武器和干预
参与者组/臂 |
干预/治疗 |
|---|---|
|
有源比较器:Sequence A
Participants received the three impression techniques in the following order: Conventional Impression Technique Digital Impression with Nonmodified Scan Body Digital Impression with Modified Scan Body |
Conventional implant impression using impression copings and elastomeric impression material.
Digital implant impression obtained using nonmodified implant scan bodies
Digital implant impression obtained using subtractively modified implant scan bodies
|
|
有源比较器:Sequence B
Participants received the three impression techniques in the following order: Digital Impression with Nonmodified Scan Body Digital Impression with Modified Scan Body Conventional Impression Technique |
Conventional implant impression using impression copings and elastomeric impression material.
Digital implant impression obtained using nonmodified implant scan bodies
Digital implant impression obtained using subtractively modified implant scan bodies
|
|
有源比较器:Sequence C
Participants received the three impression techniques in the following order: Digital Impression with Modified Scan Body Conventional Impression Technique Digital Impression with Nonmodified Scan Body |
Conventional implant impression using impression copings and elastomeric impression material.
Digital implant impression obtained using nonmodified implant scan bodies
Digital implant impression obtained using subtractively modified implant scan bodies
|
研究衡量的是什么?
主要结果指标
结果测量 |
措施说明 |
大体时间 |
|---|---|---|
|
Mean horizontal misfit (µm)
大体时间:Day 1
|
Mean horizontal misfit using the triple-scan protocol and STL file superimposition in software.
Results will be reported in micrometers (µm).
|
Day 1
|
|
Mean vertical misfit (µm)
大体时间:Day 1
|
Mean vertical misfit using the triple-scan protocol and STL file superimposition in software.
Results will be reported in micrometers (µm).
|
Day 1
|
合作者和调查者
研究记录日期
研究主要日期
学习开始 (实际的)
初级完成 (实际的)
研究完成 (实际的)
研究注册日期
首次提交
首先提交符合 QC 标准的
首次发布 (实际的)
研究记录更新
最后更新发布 (实际的)
上次提交的符合 QC 标准的更新
最后验证
更多信息
与本研究相关的术语
其他研究编号
- R.25.09.24
药物和器械信息、研究文件
研究美国 FDA 监管的药品
研究美国 FDA 监管的设备产品
此信息直接从 clinicaltrials.gov 网站检索,没有任何更改。如果您有任何更改、删除或更新研究详细信息的请求,请联系 register@clinicaltrials.gov. clinicaltrials.gov 上实施更改,我们的网站上也会自动更新.