A Longitudinal Natural History Study of OPA1-Associated Autosomal-Dominant Optic Atrophy (OPA-LONG)
2026年7月21日 更新者:Maximilian-Joachim Gerhardt、Ludwig-Maximilians - University of Munich
Clinical Characterisation of OPA1-Associated Autosomal-Dominant Optic Atrophy
This prospective, monocenter, non-interventional observational study investigates the natural history as well as the clinical and genetic spectrum of OPA1-associated autosomal dominant optic atrophy.
Participants will undergo standardized ophthalmic and functional assessments, including visual acuity testing, visual field testing, color vision and contrast sensitivity testing, optical coherence tomography, retinal flavoprotein fluorescence imaging, and video-oculography-based ocular motor and pupillary measurements.
The study aims to characterize disease severity and progression over time and to identify structural, metabolic, and functional biomarkers that may serve as clinical endpoints for future therapeutic studies.
調査の概要
状態
募集
研究の種類
観察的
入学 (推定)
50
連絡先と場所
このセクションには、調査を実施する担当者の連絡先の詳細と、この調査が実施されている場所に関する情報が記載されています。
研究連絡先
- 名前:Sarah Marxsen
- 電話番号:+49 89 4400 53770
- メール:sarah.marxsen@med.uni-muenchen.de
研究連絡先のバックアップ
- 名前:Ursula Reinstein, Dr. med. vet.
- メール:ursula.reinstein@med.uni-muenchen.de
研究場所
-
-
Bavaria
-
Munich、Bavaria、ドイツ、80336
- 募集
- Department of Ophthalmology, LMU University Hospital, LMU Medizin, Ludwig-Maximilians-Universität München
-
コンタクト:
- Sarah Marxsen
- 電話番号:+49-89-4400-53770
- メール:sarah.marxsen@med.uni-muenchen.de
-
副調査官:
- Claudia Priglinger, Prof. Dr. med.
-
副調査官:
- Günther Rudolph, Prof. Dr. med.
-
-
参加基準
研究者は、適格基準と呼ばれる特定の説明に適合する人を探します。これらの基準のいくつかの例は、人の一般的な健康状態または以前の治療です。
適格基準
就学可能な年齢
- 子
- 大人
- 高齢者
健康ボランティアの受け入れ
いいえ
サンプリング方法
非確率サンプル
調査対象母集団
Participants will be recruited from the inherited retinal disease and ophthalmogenetics clinic of the Department of Ophthalmology, University Hospital, Ludwig-Maximilians-Universität München, Germany.
The study population consists of patients followed at this tertiary referral center.
Additional participants may be referred by genetic diagnostic centers or other physicians in Germany or abroad after molecular genetic testing and clinical suspicion of OPA1-related disease.
Self-referral by patients with a previous diagnosis of OPA1-associated autosomal dominant optic atrophy is also accepted.
説明
Inclusion Criteria:
- Age 6 years or older
- Clinical diagnosis or clinical features consistent with optic atrophy
- Molecular genetic confirmation of a pathogenic or likely pathogenic variant in the OPA1 gene
- Ability of the participant, or the participant's parent or legal guardian, to understand the nature of the study and provide written informed consent
(Participants are eligible for inclusion if all of the criteria mentioned above are met)
Exclusion Criteria:
- Severe systemic disease or medical condition that, in the opinion of the investigator, would preclude participation in the study-related examinations
研究計画
このセクションでは、研究がどのように設計され、研究が何を測定しているかなど、研究計画の詳細を提供します。
研究はどのように設計されていますか?
デザインの詳細
この研究は何を測定していますか?
主要な結果の測定
結果測定 |
メジャーの説明 |
時間枠 |
|---|---|---|
|
Change in 2.5% low-contrast visual acuity measured with Sloan letter charts
時間枠:Baseline and follow-up visits up to 3 years
|
Change from baseline in low-contrast visual acuity measured using 2.5% low-contrast Sloan letter charts.
Low-contrast visual acuity will be recorded as the number of Sloan letters correctly read and may be converted to logMAR for analysis.
The unit of measure is number of Sloan letters correctly read.
|
Baseline and follow-up visits up to 3 years
|
|
Change in contrast sensitivity
時間枠:Baseline and follow-up visits up to 3 years
|
Change from baseline in contrast sensitivity measured using the Manifold® Platform from Adaptive Sensory Technology.
The unit of measure is log contrast sensitivity.
|
Baseline and follow-up visits up to 3 years
|
|
Change in macular ganglion cell layer thickness measured by optical coherence tomography
時間枠:Baseline and follow-up visits up to 3 years
|
Change from baseline in macular ganglion cell layer thickness, or ganglion cell-inner plexiform layer thickness where applicable, measured by optical coherence tomography.
The unit of measure is micrometers.
|
Baseline and follow-up visits up to 3 years
|
|
Change in peripapillary retinal nerve fiber layer thickness measured by optical coherence tomography
時間枠:Baseline and follow-up visits up to 3 years
|
Change from baseline in peripapillary retinal nerve fiber layer thickness measured by optical coherence tomography.
The unit of measure is micrometers.
|
Baseline and follow-up visits up to 3 years
|
二次結果の測定
結果測定 |
メジャーの説明 |
時間枠 |
|---|---|---|
|
Change in retinal flavoprotein fluorescence intensity measured by flavoprotein fluorescence imaging
時間枠:Baseline and follow-up visits up to 3 years
|
Change from baseline in retinal autofluorescence intensity measured using the OcuMet Beacon confocal scanning ophthalmoscope.
The unit of measure is a device-specific autofluorescence intensity score.
|
Baseline and follow-up visits up to 3 years
|
|
Change in central visual field sensitivity measured by Humphrey 10-2 automated perimetry
時間枠:Baseline and follow-up visits up to 3 years
|
Change from baseline in central visual field sensitivity measured using Humphrey 10-2 automated perimetry.
The unit of measure is decibels.
|
Baseline and follow-up visits up to 3 years
|
|
Change in protan and tritan colour contrast thresholds measured by the Arden Colour Contrast Test
時間枠:Baseline and follow-up visits up to 3 years
|
Change from baseline in protan and tritan colour contrast thresholds measured using the Arden Colour Contrast Test.
Protan and tritan thresholds will be reported separately.
The unit of measure is percent contrast.
|
Baseline and follow-up visits up to 3 years
|
|
Change in best-corrected visual acuity (BCVA) measured with high-contrast visual acuity testing
時間枠:Baseline and follow-up visits up to 3 years
|
Change from baseline in best-corrected visual acuity (BCVA) measured using standardized high-contrast visual acuity testing.
BCVA will be recorded as the number of letters correctly read or converted to logMAR for analysis.
The unit of measure is logMAR or number of letters correctly read.
|
Baseline and follow-up visits up to 3 years
|
その他の成果指標
結果測定 |
メジャーの説明 |
時間枠 |
|---|---|---|
|
Change in pupil diameter measured by video-oculography using BulbiCAM
時間枠:Baseline and follow-up visits up to 3 years
|
Change from baseline in pupil diameter measured by video-oculography using the BulbiCAM Pupil Dynamics test.
The unit of measure is millimeters.
|
Baseline and follow-up visits up to 3 years
|
|
Change in pupillary peak velocity measured by video-oculography using BulbiCAM
時間枠:Baseline and follow-up visits up to 3 years
|
Change from baseline in pupillary peak constriction and dilation velocity measured by video-oculography using the BulbiCAM Pupil Dynamics test.
Constriction and dilation velocity will be reported separately.
The unit of measure is millimeters per second.
|
Baseline and follow-up visits up to 3 years
|
|
Change in cumulative fixation time measured by BulbiCAM Fixation test
時間枠:Baseline and follow-up visits up to 3 years
|
Change from baseline in the cumulative fixation time measured using the BulbiCAM.
The unit of measure is seconds.
|
Baseline and follow-up visits up to 3 years
|
|
Change in smooth pursuit gain measured by video-oculography using BulbiCAM
時間枠:Baseline and follow-up visits up to 3 years
|
Change from baseline in device-derived smooth pursuit gain measured during the BulbiCAM Smooth Pursuit test.
The unit of measure is percent.
|
Baseline and follow-up visits up to 3 years
|
|
Change in objective central visual field sensitivity measured by KONAN ObjectiveFIELD Analyzer
時間枠:Baseline and follow-up visits up to 3 years
|
Change from baseline in objective central visual field sensitivity measured using the KONAN ObjectiveFIELD Analyzer with multifocal pupillographic objective perimetry.
The unit of measure is decibels.
|
Baseline and follow-up visits up to 3 years
|
協力者と研究者
ここでは、この調査に関係する人々や組織を見つけることができます。
捜査官
- 主任研究者:Maximilian-Joachim Gerhardt, Dr. med.、Department of Ophthalmology, LMU University Hospital, Ludwig-Maximilians-Universität München
研究記録日
これらの日付は、ClinicalTrials.gov への研究記録と要約結果の提出の進捗状況を追跡します。研究記録と報告された結果は、国立医学図書館 (NLM) によって審査され、公開 Web サイトに掲載される前に、特定の品質管理基準を満たしていることが確認されます。
主要日程の研究
研究開始 (実際)
2026年7月16日
一次修了 (推定)
2030年10月1日
研究の完了 (推定)
2030年11月1日
試験登録日
最初に提出
2026年6月21日
QC基準を満たした最初の提出物
2026年7月21日
最初の投稿 (実際)
2026年7月28日
学習記録の更新
投稿された最後の更新 (実際)
2026年7月28日
QC基準を満たした最後の更新が送信されました
2026年7月21日
最終確認日
2026年7月1日
詳しくは
本研究に関する用語
追加の関連 MeSH 用語
その他の研究ID番号
- 25-0268
個々の参加者データ (IPD) の計画
個々の参加者データ (IPD) を共有する予定はありますか?
いいえ
医薬品およびデバイス情報、研究文書
米国FDA規制医薬品の研究
いいえ
米国FDA規制機器製品の研究
いいえ
この情報は、Web サイト clinicaltrials.gov から変更なしで直接取得したものです。研究の詳細を変更、削除、または更新するリクエストがある場合は、register@clinicaltrials.gov。 までご連絡ください。 clinicaltrials.gov に変更が加えられるとすぐに、ウェブサイトでも自動的に更新されます。