- ICH GCP
- Registro degli studi clinici negli Stati Uniti
- Sperimentazione clinica NCT07729982
A Longitudinal Natural History Study of OPA1-Associated Autosomal-Dominant Optic Atrophy (OPA-LONG)
21 luglio 2026 aggiornato da: Maximilian-Joachim Gerhardt, Ludwig-Maximilians - University of Munich
Clinical Characterisation of OPA1-Associated Autosomal-Dominant Optic Atrophy
This prospective, monocenter, non-interventional observational study investigates the natural history as well as the clinical and genetic spectrum of OPA1-associated autosomal dominant optic atrophy.
Participants will undergo standardized ophthalmic and functional assessments, including visual acuity testing, visual field testing, color vision and contrast sensitivity testing, optical coherence tomography, retinal flavoprotein fluorescence imaging, and video-oculography-based ocular motor and pupillary measurements.
The study aims to characterize disease severity and progression over time and to identify structural, metabolic, and functional biomarkers that may serve as clinical endpoints for future therapeutic studies.
Panoramica dello studio
Stato
Reclutamento
Tipo di studio
Osservativo
Iscrizione (Stimato)
50
Contatti e Sedi
Questa sezione fornisce i recapiti di coloro che conducono lo studio e informazioni su dove viene condotto lo studio.
Contatto studio
- Nome: Sarah Marxsen
- Numero di telefono: +49 89 4400 53770
- Email: sarah.marxsen@med.uni-muenchen.de
Backup dei contatti dello studio
- Nome: Ursula Reinstein, Dr. med. vet.
- Email: ursula.reinstein@med.uni-muenchen.de
Luoghi di studio
-
-
Bavaria
-
Munich, Bavaria, Germania, 80336
- Reclutamento
- Department of Ophthalmology, LMU University Hospital, LMU Medizin, Ludwig-Maximilians-Universität München
-
Contatto:
- Sarah Marxsen
- Numero di telefono: +49-89-4400-53770
- Email: sarah.marxsen@med.uni-muenchen.de
-
Sub-investigatore:
- Claudia Priglinger, Prof. Dr. med.
-
Sub-investigatore:
- Günther Rudolph, Prof. Dr. med.
-
-
Criteri di partecipazione
I ricercatori cercano persone che corrispondano a una certa descrizione, chiamata criteri di ammissibilità. Alcuni esempi di questi criteri sono le condizioni generali di salute di una persona o trattamenti precedenti.
Criteri di ammissibilità
Età idonea allo studio
- Bambino
- Adulto
- Adulto più anziano
Accetta volontari sani
No
Metodo di campionamento
Campione non probabilistico
Popolazione di studio
Participants will be recruited from the inherited retinal disease and ophthalmogenetics clinic of the Department of Ophthalmology, University Hospital, Ludwig-Maximilians-Universität München, Germany.
The study population consists of patients followed at this tertiary referral center.
Additional participants may be referred by genetic diagnostic centers or other physicians in Germany or abroad after molecular genetic testing and clinical suspicion of OPA1-related disease.
Self-referral by patients with a previous diagnosis of OPA1-associated autosomal dominant optic atrophy is also accepted.
Descrizione
Inclusion Criteria:
- Age 6 years or older
- Clinical diagnosis or clinical features consistent with optic atrophy
- Molecular genetic confirmation of a pathogenic or likely pathogenic variant in the OPA1 gene
- Ability of the participant, or the participant's parent or legal guardian, to understand the nature of the study and provide written informed consent
(Participants are eligible for inclusion if all of the criteria mentioned above are met)
Exclusion Criteria:
- Severe systemic disease or medical condition that, in the opinion of the investigator, would preclude participation in the study-related examinations
Piano di studio
Questa sezione fornisce i dettagli del piano di studio, compreso il modo in cui lo studio è progettato e ciò che lo studio sta misurando.
Come è strutturato lo studio?
Dettagli di progettazione
Cosa sta misurando lo studio?
Misure di risultato primarie
Misura del risultato |
Misura Descrizione |
Lasso di tempo |
|---|---|---|
|
Change in 2.5% low-contrast visual acuity measured with Sloan letter charts
Lasso di tempo: Baseline and follow-up visits up to 3 years
|
Change from baseline in low-contrast visual acuity measured using 2.5% low-contrast Sloan letter charts.
Low-contrast visual acuity will be recorded as the number of Sloan letters correctly read and may be converted to logMAR for analysis.
The unit of measure is number of Sloan letters correctly read.
|
Baseline and follow-up visits up to 3 years
|
|
Change in contrast sensitivity
Lasso di tempo: Baseline and follow-up visits up to 3 years
|
Change from baseline in contrast sensitivity measured using the Manifold® Platform from Adaptive Sensory Technology.
The unit of measure is log contrast sensitivity.
|
Baseline and follow-up visits up to 3 years
|
|
Change in macular ganglion cell layer thickness measured by optical coherence tomography
Lasso di tempo: Baseline and follow-up visits up to 3 years
|
Change from baseline in macular ganglion cell layer thickness, or ganglion cell-inner plexiform layer thickness where applicable, measured by optical coherence tomography.
The unit of measure is micrometers.
|
Baseline and follow-up visits up to 3 years
|
|
Change in peripapillary retinal nerve fiber layer thickness measured by optical coherence tomography
Lasso di tempo: Baseline and follow-up visits up to 3 years
|
Change from baseline in peripapillary retinal nerve fiber layer thickness measured by optical coherence tomography.
The unit of measure is micrometers.
|
Baseline and follow-up visits up to 3 years
|
Misure di risultato secondarie
Misura del risultato |
Misura Descrizione |
Lasso di tempo |
|---|---|---|
|
Change in retinal flavoprotein fluorescence intensity measured by flavoprotein fluorescence imaging
Lasso di tempo: Baseline and follow-up visits up to 3 years
|
Change from baseline in retinal autofluorescence intensity measured using the OcuMet Beacon confocal scanning ophthalmoscope.
The unit of measure is a device-specific autofluorescence intensity score.
|
Baseline and follow-up visits up to 3 years
|
|
Change in central visual field sensitivity measured by Humphrey 10-2 automated perimetry
Lasso di tempo: Baseline and follow-up visits up to 3 years
|
Change from baseline in central visual field sensitivity measured using Humphrey 10-2 automated perimetry.
The unit of measure is decibels.
|
Baseline and follow-up visits up to 3 years
|
|
Change in protan and tritan colour contrast thresholds measured by the Arden Colour Contrast Test
Lasso di tempo: Baseline and follow-up visits up to 3 years
|
Change from baseline in protan and tritan colour contrast thresholds measured using the Arden Colour Contrast Test.
Protan and tritan thresholds will be reported separately.
The unit of measure is percent contrast.
|
Baseline and follow-up visits up to 3 years
|
|
Change in best-corrected visual acuity (BCVA) measured with high-contrast visual acuity testing
Lasso di tempo: Baseline and follow-up visits up to 3 years
|
Change from baseline in best-corrected visual acuity (BCVA) measured using standardized high-contrast visual acuity testing.
BCVA will be recorded as the number of letters correctly read or converted to logMAR for analysis.
The unit of measure is logMAR or number of letters correctly read.
|
Baseline and follow-up visits up to 3 years
|
Altre misure di risultato
Misura del risultato |
Misura Descrizione |
Lasso di tempo |
|---|---|---|
|
Change in pupil diameter measured by video-oculography using BulbiCAM
Lasso di tempo: Baseline and follow-up visits up to 3 years
|
Change from baseline in pupil diameter measured by video-oculography using the BulbiCAM Pupil Dynamics test.
The unit of measure is millimeters.
|
Baseline and follow-up visits up to 3 years
|
|
Change in pupillary peak velocity measured by video-oculography using BulbiCAM
Lasso di tempo: Baseline and follow-up visits up to 3 years
|
Change from baseline in pupillary peak constriction and dilation velocity measured by video-oculography using the BulbiCAM Pupil Dynamics test.
Constriction and dilation velocity will be reported separately.
The unit of measure is millimeters per second.
|
Baseline and follow-up visits up to 3 years
|
|
Change in cumulative fixation time measured by BulbiCAM Fixation test
Lasso di tempo: Baseline and follow-up visits up to 3 years
|
Change from baseline in the cumulative fixation time measured using the BulbiCAM.
The unit of measure is seconds.
|
Baseline and follow-up visits up to 3 years
|
|
Change in smooth pursuit gain measured by video-oculography using BulbiCAM
Lasso di tempo: Baseline and follow-up visits up to 3 years
|
Change from baseline in device-derived smooth pursuit gain measured during the BulbiCAM Smooth Pursuit test.
The unit of measure is percent.
|
Baseline and follow-up visits up to 3 years
|
|
Change in objective central visual field sensitivity measured by KONAN ObjectiveFIELD Analyzer
Lasso di tempo: Baseline and follow-up visits up to 3 years
|
Change from baseline in objective central visual field sensitivity measured using the KONAN ObjectiveFIELD Analyzer with multifocal pupillographic objective perimetry.
The unit of measure is decibels.
|
Baseline and follow-up visits up to 3 years
|
Collaboratori e investigatori
Qui è dove troverai le persone e le organizzazioni coinvolte in questo studio.
Investigatori
- Investigatore principale: Maximilian-Joachim Gerhardt, Dr. med., Department of Ophthalmology, LMU University Hospital, Ludwig-Maximilians-Universität München
Studiare le date dei record
Queste date tengono traccia dell'avanzamento della registrazione dello studio e dell'invio dei risultati di sintesi a ClinicalTrials.gov. I record degli studi e i risultati riportati vengono esaminati dalla National Library of Medicine (NLM) per assicurarsi che soddisfino specifici standard di controllo della qualità prima di essere pubblicati sul sito Web pubblico.
Studia le date principali
Inizio studio (Effettivo)
16 luglio 2026
Completamento primario (Stimato)
1 ottobre 2030
Completamento dello studio (Stimato)
1 novembre 2030
Date di iscrizione allo studio
Primo inviato
21 giugno 2026
Primo inviato che soddisfa i criteri di controllo qualità
21 luglio 2026
Primo Inserito (Effettivo)
28 luglio 2026
Aggiornamenti dei record di studio
Ultimo aggiornamento pubblicato (Effettivo)
28 luglio 2026
Ultimo aggiornamento inviato che soddisfa i criteri QC
21 luglio 2026
Ultimo verificato
1 luglio 2026
Maggiori informazioni
Termini relativi a questo studio
Termini MeSH pertinenti aggiuntivi
- Malattie del sistema nervoso
- Malattie genetiche, congenite
- Malattie metaboliche
- Malattie degli occhi
- Malattie Neurodegenerative
- Malattie degli occhi, ereditarie
- Malattie Eredodegenerative, Sistema Nervoso
- Malattie del nervo ottico
- Malattie dei nervi cranici
- Malattie mitocondriali
- Atrofie ottiche, ereditarie
- Atrofia ottica
- Malattie e anomalie congenite, ereditarie e neonatali
- Malattie nutrizionali e metaboliche
- Atrofia ottica, autosomica dominante
Altri numeri di identificazione dello studio
- 25-0268
Piano per i dati dei singoli partecipanti (IPD)
Hai intenzione di condividere i dati dei singoli partecipanti (IPD)?
NO
Informazioni su farmaci e dispositivi, documenti di studio
Studia un prodotto farmaceutico regolamentato dalla FDA degli Stati Uniti
No
Studia un dispositivo regolamentato dalla FDA degli Stati Uniti
No
Queste informazioni sono state recuperate direttamente dal sito web clinicaltrials.gov senza alcuna modifica. In caso di richieste di modifica, rimozione o aggiornamento dei dettagli dello studio, contattare register@clinicaltrials.gov. Non appena verrà implementata una modifica su clinicaltrials.gov, questa verrà aggiornata automaticamente anche sul nostro sito web .