- ICH GCP
- US-Register für klinische Studien
- Klinische Studie NCT07729982
A Longitudinal Natural History Study of OPA1-Associated Autosomal-Dominant Optic Atrophy (OPA-LONG)
21. Juli 2026 aktualisiert von: Maximilian-Joachim Gerhardt, Ludwig-Maximilians - University of Munich
Clinical Characterisation of OPA1-Associated Autosomal-Dominant Optic Atrophy
This prospective, monocenter, non-interventional observational study investigates the natural history as well as the clinical and genetic spectrum of OPA1-associated autosomal dominant optic atrophy.
Participants will undergo standardized ophthalmic and functional assessments, including visual acuity testing, visual field testing, color vision and contrast sensitivity testing, optical coherence tomography, retinal flavoprotein fluorescence imaging, and video-oculography-based ocular motor and pupillary measurements.
The study aims to characterize disease severity and progression over time and to identify structural, metabolic, and functional biomarkers that may serve as clinical endpoints for future therapeutic studies.
Studienübersicht
Status
Rekrutierung
Bedingungen
Studientyp
Beobachtungs
Einschreibung (Geschätzt)
50
Kontakte und Standorte
Dieser Abschnitt enthält die Kontaktdaten derjenigen, die die Studie durchführen, und Informationen darüber, wo diese Studie durchgeführt wird.
Studienkontakt
- Name: Sarah Marxsen
- Telefonnummer: +49 89 4400 53770
- E-Mail: sarah.marxsen@med.uni-muenchen.de
Studieren Sie die Kontaktsicherung
- Name: Ursula Reinstein, Dr. med. vet.
- E-Mail: ursula.reinstein@med.uni-muenchen.de
Studienorte
-
-
Bavaria
-
Munich, Bavaria, Deutschland, 80336
- Rekrutierung
- Department of Ophthalmology, LMU University Hospital, LMU Medizin, Ludwig-Maximilians-Universität München
-
Kontakt:
- Sarah Marxsen
- Telefonnummer: +49-89-4400-53770
- E-Mail: sarah.marxsen@med.uni-muenchen.de
-
Unterermittler:
- Claudia Priglinger, Prof. Dr. med.
-
Unterermittler:
- Günther Rudolph, Prof. Dr. med.
-
-
Teilnahmekriterien
Forscher suchen nach Personen, die einer bestimmten Beschreibung entsprechen, die als Auswahlkriterien bezeichnet werden. Einige Beispiele für diese Kriterien sind der allgemeine Gesundheitszustand einer Person oder frühere Behandlungen.
Zulassungskriterien
Studienberechtigtes Alter
- Kind
- Erwachsene
- Älterer Erwachsener
Akzeptiert gesunde Freiwillige
Nein
Probenahmeverfahren
Nicht-Wahrscheinlichkeitsprobe
Studienpopulation
Participants will be recruited from the inherited retinal disease and ophthalmogenetics clinic of the Department of Ophthalmology, University Hospital, Ludwig-Maximilians-Universität München, Germany.
The study population consists of patients followed at this tertiary referral center.
Additional participants may be referred by genetic diagnostic centers or other physicians in Germany or abroad after molecular genetic testing and clinical suspicion of OPA1-related disease.
Self-referral by patients with a previous diagnosis of OPA1-associated autosomal dominant optic atrophy is also accepted.
Beschreibung
Inclusion Criteria:
- Age 6 years or older
- Clinical diagnosis or clinical features consistent with optic atrophy
- Molecular genetic confirmation of a pathogenic or likely pathogenic variant in the OPA1 gene
- Ability of the participant, or the participant's parent or legal guardian, to understand the nature of the study and provide written informed consent
(Participants are eligible for inclusion if all of the criteria mentioned above are met)
Exclusion Criteria:
- Severe systemic disease or medical condition that, in the opinion of the investigator, would preclude participation in the study-related examinations
Studienplan
Dieser Abschnitt enthält Einzelheiten zum Studienplan, einschließlich des Studiendesigns und der Messung der Studieninhalte.
Wie ist die Studie aufgebaut?
Designdetails
Was misst die Studie?
Primäre Ergebnismessungen
Ergebnis Maßnahme |
Maßnahmenbeschreibung |
Zeitfenster |
|---|---|---|
|
Change in 2.5% low-contrast visual acuity measured with Sloan letter charts
Zeitfenster: Baseline and follow-up visits up to 3 years
|
Change from baseline in low-contrast visual acuity measured using 2.5% low-contrast Sloan letter charts.
Low-contrast visual acuity will be recorded as the number of Sloan letters correctly read and may be converted to logMAR for analysis.
The unit of measure is number of Sloan letters correctly read.
|
Baseline and follow-up visits up to 3 years
|
|
Change in contrast sensitivity
Zeitfenster: Baseline and follow-up visits up to 3 years
|
Change from baseline in contrast sensitivity measured using the Manifold® Platform from Adaptive Sensory Technology.
The unit of measure is log contrast sensitivity.
|
Baseline and follow-up visits up to 3 years
|
|
Change in macular ganglion cell layer thickness measured by optical coherence tomography
Zeitfenster: Baseline and follow-up visits up to 3 years
|
Change from baseline in macular ganglion cell layer thickness, or ganglion cell-inner plexiform layer thickness where applicable, measured by optical coherence tomography.
The unit of measure is micrometers.
|
Baseline and follow-up visits up to 3 years
|
|
Change in peripapillary retinal nerve fiber layer thickness measured by optical coherence tomography
Zeitfenster: Baseline and follow-up visits up to 3 years
|
Change from baseline in peripapillary retinal nerve fiber layer thickness measured by optical coherence tomography.
The unit of measure is micrometers.
|
Baseline and follow-up visits up to 3 years
|
Sekundäre Ergebnismessungen
Ergebnis Maßnahme |
Maßnahmenbeschreibung |
Zeitfenster |
|---|---|---|
|
Change in retinal flavoprotein fluorescence intensity measured by flavoprotein fluorescence imaging
Zeitfenster: Baseline and follow-up visits up to 3 years
|
Change from baseline in retinal autofluorescence intensity measured using the OcuMet Beacon confocal scanning ophthalmoscope.
The unit of measure is a device-specific autofluorescence intensity score.
|
Baseline and follow-up visits up to 3 years
|
|
Change in central visual field sensitivity measured by Humphrey 10-2 automated perimetry
Zeitfenster: Baseline and follow-up visits up to 3 years
|
Change from baseline in central visual field sensitivity measured using Humphrey 10-2 automated perimetry.
The unit of measure is decibels.
|
Baseline and follow-up visits up to 3 years
|
|
Change in protan and tritan colour contrast thresholds measured by the Arden Colour Contrast Test
Zeitfenster: Baseline and follow-up visits up to 3 years
|
Change from baseline in protan and tritan colour contrast thresholds measured using the Arden Colour Contrast Test.
Protan and tritan thresholds will be reported separately.
The unit of measure is percent contrast.
|
Baseline and follow-up visits up to 3 years
|
|
Change in best-corrected visual acuity (BCVA) measured with high-contrast visual acuity testing
Zeitfenster: Baseline and follow-up visits up to 3 years
|
Change from baseline in best-corrected visual acuity (BCVA) measured using standardized high-contrast visual acuity testing.
BCVA will be recorded as the number of letters correctly read or converted to logMAR for analysis.
The unit of measure is logMAR or number of letters correctly read.
|
Baseline and follow-up visits up to 3 years
|
Andere Ergebnismessungen
Ergebnis Maßnahme |
Maßnahmenbeschreibung |
Zeitfenster |
|---|---|---|
|
Change in pupil diameter measured by video-oculography using BulbiCAM
Zeitfenster: Baseline and follow-up visits up to 3 years
|
Change from baseline in pupil diameter measured by video-oculography using the BulbiCAM Pupil Dynamics test.
The unit of measure is millimeters.
|
Baseline and follow-up visits up to 3 years
|
|
Change in pupillary peak velocity measured by video-oculography using BulbiCAM
Zeitfenster: Baseline and follow-up visits up to 3 years
|
Change from baseline in pupillary peak constriction and dilation velocity measured by video-oculography using the BulbiCAM Pupil Dynamics test.
Constriction and dilation velocity will be reported separately.
The unit of measure is millimeters per second.
|
Baseline and follow-up visits up to 3 years
|
|
Change in cumulative fixation time measured by BulbiCAM Fixation test
Zeitfenster: Baseline and follow-up visits up to 3 years
|
Change from baseline in the cumulative fixation time measured using the BulbiCAM.
The unit of measure is seconds.
|
Baseline and follow-up visits up to 3 years
|
|
Change in smooth pursuit gain measured by video-oculography using BulbiCAM
Zeitfenster: Baseline and follow-up visits up to 3 years
|
Change from baseline in device-derived smooth pursuit gain measured during the BulbiCAM Smooth Pursuit test.
The unit of measure is percent.
|
Baseline and follow-up visits up to 3 years
|
|
Change in objective central visual field sensitivity measured by KONAN ObjectiveFIELD Analyzer
Zeitfenster: Baseline and follow-up visits up to 3 years
|
Change from baseline in objective central visual field sensitivity measured using the KONAN ObjectiveFIELD Analyzer with multifocal pupillographic objective perimetry.
The unit of measure is decibels.
|
Baseline and follow-up visits up to 3 years
|
Mitarbeiter und Ermittler
Hier finden Sie Personen und Organisationen, die an dieser Studie beteiligt sind.
Ermittler
- Hauptermittler: Maximilian-Joachim Gerhardt, Dr. med., Department of Ophthalmology, LMU University Hospital, Ludwig-Maximilians-Universität München
Studienaufzeichnungsdaten
Diese Daten verfolgen den Fortschritt der Übermittlung von Studienaufzeichnungen und zusammenfassenden Ergebnissen an ClinicalTrials.gov. Studienaufzeichnungen und gemeldete Ergebnisse werden von der National Library of Medicine (NLM) überprüft, um sicherzustellen, dass sie bestimmten Qualitätskontrollstandards entsprechen, bevor sie auf der öffentlichen Website veröffentlicht werden.
Haupttermine studieren
Studienbeginn (Tatsächlich)
16. Juli 2026
Primärer Abschluss (Geschätzt)
1. Oktober 2030
Studienabschluss (Geschätzt)
1. November 2030
Studienanmeldedaten
Zuerst eingereicht
21. Juni 2026
Zuerst eingereicht, das die QC-Kriterien erfüllt hat
21. Juli 2026
Zuerst gepostet (Tatsächlich)
28. Juli 2026
Studienaufzeichnungsaktualisierungen
Letztes Update gepostet (Tatsächlich)
28. Juli 2026
Letztes eingereichtes Update, das die QC-Kriterien erfüllt
21. Juli 2026
Zuletzt verifiziert
1. Juli 2026
Mehr Informationen
Begriffe im Zusammenhang mit dieser Studie
Zusätzliche relevante MeSH-Bedingungen
- Erkrankungen des Nervensystems
- Genetische Krankheiten, angeboren
- Stoffwechselerkrankungen
- Augenkrankheiten
- Neurodegenerative Krankheiten
- Augenkrankheiten, erblich
- Heredodegenerative Erkrankungen, Nervensystem
- Sehnervenerkrankungen
- Erkrankungen der Hirnnerven
- Mitochondriale Erkrankungen
- Optikusatrophien, erblich
- Optikusatrophie
- Angeborene, erbliche und neonatale Krankheiten und Anomalien
- Ernährungs- und Stoffwechselerkrankungen
- Optikusatrophie, autosomal dominant
Andere Studien-ID-Nummern
- 25-0268
Plan für individuelle Teilnehmerdaten (IPD)
Planen Sie, individuelle Teilnehmerdaten (IPD) zu teilen?
NEIN
Arzneimittel- und Geräteinformationen, Studienunterlagen
Studiert ein von der US-amerikanischen FDA reguliertes Arzneimittelprodukt
Nein
Studiert ein von der US-amerikanischen FDA reguliertes Geräteprodukt
Nein
Diese Informationen wurden ohne Änderungen direkt von der Website clinicaltrials.gov abgerufen. Wenn Sie Ihre Studiendaten ändern, entfernen oder aktualisieren möchten, wenden Sie sich bitte an register@clinicaltrials.gov. Sobald eine Änderung auf clinicaltrials.gov implementiert wird, wird diese automatisch auch auf unserer Website aktualisiert .