A Longitudinal Natural History Study of OPA1-Associated Autosomal-Dominant Optic Atrophy (OPA-LONG)

21 juillet 2026 mis à jour par: Maximilian-Joachim Gerhardt, Ludwig-Maximilians - University of Munich

Clinical Characterisation of OPA1-Associated Autosomal-Dominant Optic Atrophy

This prospective, monocenter, non-interventional observational study investigates the natural history as well as the clinical and genetic spectrum of OPA1-associated autosomal dominant optic atrophy. Participants will undergo standardized ophthalmic and functional assessments, including visual acuity testing, visual field testing, color vision and contrast sensitivity testing, optical coherence tomography, retinal flavoprotein fluorescence imaging, and video-oculography-based ocular motor and pupillary measurements. The study aims to characterize disease severity and progression over time and to identify structural, metabolic, and functional biomarkers that may serve as clinical endpoints for future therapeutic studies.

Aperçu de l'étude

Type d'étude

Observationnel

Inscription (Estimé)

50

Contacts et emplacements

Cette section fournit les coordonnées de ceux qui mènent l'étude et des informations sur le lieu où cette étude est menée.

Coordonnées de l'étude

Sauvegarde des contacts de l'étude

Lieux d'étude

    • Bavaria
      • Munich, Bavaria, Allemagne, 80336
        • Recrutement
        • Department of Ophthalmology, LMU University Hospital, LMU Medizin, Ludwig-Maximilians-Universität München
        • Contact:
        • Sous-enquêteur:
          • Claudia Priglinger, Prof. Dr. med.
        • Sous-enquêteur:
          • Günther Rudolph, Prof. Dr. med.

Critères de participation

Les chercheurs recherchent des personnes qui correspondent à une certaine description, appelée critères d'éligibilité. Certains exemples de ces critères sont l'état de santé général d'une personne ou des traitements antérieurs.

Critère d'éligibilité

Âges éligibles pour étudier

  • Enfant
  • Adulte
  • Adulte plus âgé

Accepte les volontaires sains

Non

Méthode d'échantillonnage

Échantillon non probabiliste

Population étudiée

Participants will be recruited from the inherited retinal disease and ophthalmogenetics clinic of the Department of Ophthalmology, University Hospital, Ludwig-Maximilians-Universität München, Germany. The study population consists of patients followed at this tertiary referral center. Additional participants may be referred by genetic diagnostic centers or other physicians in Germany or abroad after molecular genetic testing and clinical suspicion of OPA1-related disease. Self-referral by patients with a previous diagnosis of OPA1-associated autosomal dominant optic atrophy is also accepted.

La description

Inclusion Criteria:

  • Age 6 years or older
  • Clinical diagnosis or clinical features consistent with optic atrophy
  • Molecular genetic confirmation of a pathogenic or likely pathogenic variant in the OPA1 gene
  • Ability of the participant, or the participant's parent or legal guardian, to understand the nature of the study and provide written informed consent

(Participants are eligible for inclusion if all of the criteria mentioned above are met)

Exclusion Criteria:

- Severe systemic disease or medical condition that, in the opinion of the investigator, would preclude participation in the study-related examinations

Plan d'étude

Cette section fournit des détails sur le plan d'étude, y compris la façon dont l'étude est conçue et ce que l'étude mesure.

Comment l'étude est-elle conçue ?

Détails de conception

Que mesure l'étude ?

Principaux critères de jugement

Mesure des résultats
Description de la mesure
Délai
Change in 2.5% low-contrast visual acuity measured with Sloan letter charts
Délai: Baseline and follow-up visits up to 3 years
Change from baseline in low-contrast visual acuity measured using 2.5% low-contrast Sloan letter charts. Low-contrast visual acuity will be recorded as the number of Sloan letters correctly read and may be converted to logMAR for analysis. The unit of measure is number of Sloan letters correctly read.
Baseline and follow-up visits up to 3 years
Change in contrast sensitivity
Délai: Baseline and follow-up visits up to 3 years
Change from baseline in contrast sensitivity measured using the Manifold® Platform from Adaptive Sensory Technology. The unit of measure is log contrast sensitivity.
Baseline and follow-up visits up to 3 years
Change in macular ganglion cell layer thickness measured by optical coherence tomography
Délai: Baseline and follow-up visits up to 3 years
Change from baseline in macular ganglion cell layer thickness, or ganglion cell-inner plexiform layer thickness where applicable, measured by optical coherence tomography. The unit of measure is micrometers.
Baseline and follow-up visits up to 3 years
Change in peripapillary retinal nerve fiber layer thickness measured by optical coherence tomography
Délai: Baseline and follow-up visits up to 3 years
Change from baseline in peripapillary retinal nerve fiber layer thickness measured by optical coherence tomography. The unit of measure is micrometers.
Baseline and follow-up visits up to 3 years

Mesures de résultats secondaires

Mesure des résultats
Description de la mesure
Délai
Change in retinal flavoprotein fluorescence intensity measured by flavoprotein fluorescence imaging
Délai: Baseline and follow-up visits up to 3 years
Change from baseline in retinal autofluorescence intensity measured using the OcuMet Beacon confocal scanning ophthalmoscope. The unit of measure is a device-specific autofluorescence intensity score.
Baseline and follow-up visits up to 3 years
Change in central visual field sensitivity measured by Humphrey 10-2 automated perimetry
Délai: Baseline and follow-up visits up to 3 years
Change from baseline in central visual field sensitivity measured using Humphrey 10-2 automated perimetry. The unit of measure is decibels.
Baseline and follow-up visits up to 3 years
Change in protan and tritan colour contrast thresholds measured by the Arden Colour Contrast Test
Délai: Baseline and follow-up visits up to 3 years
Change from baseline in protan and tritan colour contrast thresholds measured using the Arden Colour Contrast Test. Protan and tritan thresholds will be reported separately. The unit of measure is percent contrast.
Baseline and follow-up visits up to 3 years
Change in best-corrected visual acuity (BCVA) measured with high-contrast visual acuity testing
Délai: Baseline and follow-up visits up to 3 years
Change from baseline in best-corrected visual acuity (BCVA) measured using standardized high-contrast visual acuity testing. BCVA will be recorded as the number of letters correctly read or converted to logMAR for analysis. The unit of measure is logMAR or number of letters correctly read.
Baseline and follow-up visits up to 3 years

Autres mesures de résultats

Mesure des résultats
Description de la mesure
Délai
Change in pupil diameter measured by video-oculography using BulbiCAM
Délai: Baseline and follow-up visits up to 3 years
Change from baseline in pupil diameter measured by video-oculography using the BulbiCAM Pupil Dynamics test. The unit of measure is millimeters.
Baseline and follow-up visits up to 3 years
Change in pupillary peak velocity measured by video-oculography using BulbiCAM
Délai: Baseline and follow-up visits up to 3 years
Change from baseline in pupillary peak constriction and dilation velocity measured by video-oculography using the BulbiCAM Pupil Dynamics test. Constriction and dilation velocity will be reported separately. The unit of measure is millimeters per second.
Baseline and follow-up visits up to 3 years
Change in cumulative fixation time measured by BulbiCAM Fixation test
Délai: Baseline and follow-up visits up to 3 years
Change from baseline in the cumulative fixation time measured using the BulbiCAM. The unit of measure is seconds.
Baseline and follow-up visits up to 3 years
Change in smooth pursuit gain measured by video-oculography using BulbiCAM
Délai: Baseline and follow-up visits up to 3 years
Change from baseline in device-derived smooth pursuit gain measured during the BulbiCAM Smooth Pursuit test. The unit of measure is percent.
Baseline and follow-up visits up to 3 years
Change in objective central visual field sensitivity measured by KONAN ObjectiveFIELD Analyzer
Délai: Baseline and follow-up visits up to 3 years
Change from baseline in objective central visual field sensitivity measured using the KONAN ObjectiveFIELD Analyzer with multifocal pupillographic objective perimetry. The unit of measure is decibels.
Baseline and follow-up visits up to 3 years

Collaborateurs et enquêteurs

C'est ici que vous trouverez les personnes et les organisations impliquées dans cette étude.

Les enquêteurs

  • Chercheur principal: Maximilian-Joachim Gerhardt, Dr. med., Department of Ophthalmology, LMU University Hospital, Ludwig-Maximilians-Universität München

Dates d'enregistrement des études

Ces dates suivent la progression des dossiers d'étude et des soumissions de résultats sommaires à ClinicalTrials.gov. Les dossiers d'étude et les résultats rapportés sont examinés par la Bibliothèque nationale de médecine (NLM) pour s'assurer qu'ils répondent à des normes de contrôle de qualité spécifiques avant d'être publiés sur le site Web public.

Dates principales de l'étude

Début de l'étude (Réel)

16 juillet 2026

Achèvement primaire (Estimé)

1 octobre 2030

Achèvement de l'étude (Estimé)

1 novembre 2030

Dates d'inscription aux études

Première soumission

21 juin 2026

Première soumission répondant aux critères de contrôle qualité

21 juillet 2026

Première publication (Réel)

28 juillet 2026

Mises à jour des dossiers d'étude

Dernière mise à jour publiée (Réel)

28 juillet 2026

Dernière mise à jour soumise répondant aux critères de contrôle qualité

21 juillet 2026

Dernière vérification

1 juillet 2026

Plus d'information

Termes liés à cette étude

Plan pour les données individuelles des participants (IPD)

Prévoyez-vous de partager les données individuelles des participants (DPI) ?

NON

Informations sur les médicaments et les dispositifs, documents d'étude

Étudie un produit pharmaceutique réglementé par la FDA américaine

Non

Étudie un produit d'appareil réglementé par la FDA américaine

Non

Ces informations ont été extraites directement du site Web clinicaltrials.gov sans aucune modification. Si vous avez des demandes de modification, de suppression ou de mise à jour des détails de votre étude, veuillez contacter register@clinicaltrials.gov. Dès qu'un changement est mis en œuvre sur clinicaltrials.gov, il sera également mis à jour automatiquement sur notre site Web .

S'abonner