Passive Fit of Implant-Supported Frameworks: Digital vs Conventional Impressions
Passive Fit Evaluation of Full-Arch Implant-supported Frameworks Using Digital and Conventional Impression Techniques: Crossover Study
調査の概要
状態
詳細な説明
Full-arch implant-supported fixed prostheses require a high degree of passive fit to avoid mechanical and biological complications. While digital impression workflows are increasingly used as alternatives to conventional splinted impressions, evidence directly comparing their clinical accuracy for complete-arch implant frameworks remains limited, particularly for the IO-Connect non-calibrated splinting system and the Reverse Scan Body technique.
Eight completely edentulous patients with at least four mandibular implants will be enrolled. Using a crossover design, each patient will undergo all three impression techniques: Group I (IO-Connect splinted scan bodies), Group II (Reverse Scan Body technique), and Group III (conventional splinted open-tray impression with polyvinyl siloxane and Type IV stone casts). For each technique, a corresponding implant-supported framework will be fabricated and evaluated for passivity of fit using the Sheffield one-screw test and periapical radiographs taken with a paralleling device to assess microgaps at the implant-framework interface.
研究の種類
入学 (推定)
段階
- 適用できない
連絡先と場所
研究連絡先
- 名前:Ahmed H Hazem Elsayed Helmi Atwa, BDS
- 電話番号:+20 1092758696
- メール:ahmedhazem@mans.edu.eg
研究場所
-
-
Dakahlia Governorate
-
Al Mansurah、Dakahlia Governorate、エジプト
- 募集
- Faculty of Dentistry, Mansoura University
-
コンタクト:
- Ahmed H Hazem Elsayed Helmi Atwa, BDS
- 電話番号:+20 1092758696
- メール:ahmedhazem@mans.edu.eg
-
主任研究者:
- Ahmed Hazem Elsayed Helmi Atwa, BDS
-
-
参加基準
適格基準
就学可能な年齢
- 大人
- 高齢者
健康ボランティアの受け入れ
説明
Inclusion Criteria:
- Completely edentulous patients requiring full-arch implant-supported fixed prosthesis
- Age 35-70 years
- Adequate mandibular bone to place at least four implants without major grafting
- Ability to undergo digital scanning and radiographic evaluation
- Signed informed consent
Exclusion Criteria:
- Systemic conditions affecting healing (uncontrolled diabetes, immunosuppression)
- History of head/neck radiotherapy or bisphosphonate therapy
- Active oral infection or severe bruxism
- Strong gag reflex preventing accurate scanning
- Poor compliance or unwillingness to attend follow-up visits
研究計画
研究はどのように設計されていますか?
デザインの詳細
- 主な目的:処理
- 割り当て:ランダム化
- 介入モデル:クロスオーバー割り当て
- マスキング:なし(オープンラベル)
武器と介入
参加者グループ / アーム |
介入・治療 |
|---|---|
|
アクティブコンパレータ:Group I: IO-Connect
Patients received complete-arch implant-supported frameworks fabricated using digital impressions obtained with IO-Connect non-calibrated splinted scan bodies.
|
Digital impression of the mandibular arch obtained using IO-Connect non-calibrated splinted scan bodies to fabricate the implant-supported framework for Group I.
|
|
アクティブコンパレータ:Group II: Reverse Scan Body
Patients received complete-arch implant-supported frameworks fabricated using digital impressions obtained with the Reverse Scan Body (RSB) technique.
|
Digital impression obtained using the Reverse Scan Body (RSB) technique, involving extraoral scanning of scan bodies and superimposition with intraoral tissue scans, to fabricate the implant-supported framework for Group II.
|
|
アクティブコンパレータ:Group III: Conventional Impression
Patients received complete-arch implant-supported frameworks fabricated using a conventional splinted open-tray impression technique.
|
Conventional splinted open-tray impression using polyvinyl siloxane material and Type IV dental stone to fabricate the implant-supported framework for Group III.
|
この研究は何を測定していますか?
主要な結果の測定
結果測定 |
メジャーの説明 |
時間枠 |
|---|---|---|
|
Passive Fit Assessed by Sheffield One-Screw Test
時間枠:The evaluation of passive fit by Sheffield one-screw test will be done 3 months after implant placement (3M-IP), at framework try-in for each of the three impression techniques.
|
The framework was seated on all implants and a single distal screw was fully tightened; remaining screw sites were examined visually and tactilely for lifting, rocking, or gaps as an indicator of passive fit.
|
The evaluation of passive fit by Sheffield one-screw test will be done 3 months after implant placement (3M-IP), at framework try-in for each of the three impression techniques.
|
|
Passive Fit Assessed by Periapical Radiographs
時間枠:The evaluation of passive fit by periapical radiographs will be done 3 months after implant placement, at framework try-in for each of the three impression techniques.
|
Intraoral periapical radiographs were obtained at each implant site using a paralleling device and evaluated for microgaps at the implant-framework interface.
|
The evaluation of passive fit by periapical radiographs will be done 3 months after implant placement, at framework try-in for each of the three impression techniques.
|
協力者と研究者
スポンサー
捜査官
- スタディチェア:Fatma A El-Waseef, PhD、Mansoura University
研究記録日
主要日程の研究
研究開始 (実際)
一次修了 (推定)
研究の完了 (推定)
試験登録日
最初に提出
QC基準を満たした最初の提出物
最初の投稿 (実際)
学習記録の更新
投稿された最後の更新 (実際)
QC基準を満たした最後の更新が送信されました
最終確認日
詳しくは
この情報は、Web サイト clinicaltrials.gov から変更なしで直接取得したものです。研究の詳細を変更、削除、または更新するリクエストがある場合は、register@clinicaltrials.gov。 までご連絡ください。 clinicaltrials.gov に変更が加えられるとすぐに、ウェブサイトでも自動的に更新されます。