Esta página se tradujo automáticamente y no se garantiza la precisión de la traducción. por favor refiérase a versión inglesa para un texto fuente.

Passive Fit of Implant-Supported Frameworks: Digital vs Conventional Impressions

20 de agosto de 2026 actualizado por: Ahmed Hazem Elsayed Helmi, Mansoura University

Passive Fit Evaluation of Full-Arch Implant-supported Frameworks Using Digital and Conventional Impression Techniques: Crossover Study

This randomized crossover clinical trial compares the passivity of fit of complete-arch mandibular implant-supported frameworks fabricated using three impression techniques: a non-calibrated splinted digital scan body system (IO-Connect), a Reverse Scan Body (RSB) digital impression technique, and a conventional splinted open-tray impression technique. Eight completely edentulous patients each receiving four mandibular implants will be included. Passivity of fit will be evaluated clinically using the Sheffield one-screw test and radiographically using intraoral periapical radiographs obtained with the parallel technique.

Descripción general del estudio

Descripción detallada

Full-arch implant-supported fixed prostheses require a high degree of passive fit to avoid mechanical and biological complications. While digital impression workflows are increasingly used as alternatives to conventional splinted impressions, evidence directly comparing their clinical accuracy for complete-arch implant frameworks remains limited, particularly for the IO-Connect non-calibrated splinting system and the Reverse Scan Body technique.

Eight completely edentulous patients with at least four mandibular implants will be enrolled. Using a crossover design, each patient will undergo all three impression techniques: Group I (IO-Connect splinted scan bodies), Group II (Reverse Scan Body technique), and Group III (conventional splinted open-tray impression with polyvinyl siloxane and Type IV stone casts). For each technique, a corresponding implant-supported framework will be fabricated and evaluated for passivity of fit using the Sheffield one-screw test and periapical radiographs taken with a paralleling device to assess microgaps at the implant-framework interface.

Tipo de estudio

Intervencionista

Inscripción (Estimado)

8

Fase

  • No aplica

Contactos y Ubicaciones

Esta sección proporciona los datos de contacto de quienes realizan el estudio e información sobre dónde se lleva a cabo este estudio.

Estudio Contacto

  • Nombre: Ahmed H Hazem Elsayed Helmi Atwa, BDS
  • Número de teléfono: +20 1092758696
  • Correo electrónico: ahmedhazem@mans.edu.eg

Ubicaciones de estudio

    • Dakahlia Governorate
      • Al Mansurah, Dakahlia Governorate, Egipto
        • Reclutamiento
        • Faculty of Dentistry, Mansoura University
        • Contacto:
          • Ahmed H Hazem Elsayed Helmi Atwa, BDS
          • Número de teléfono: +20 1092758696
          • Correo electrónico: ahmedhazem@mans.edu.eg
        • Investigador principal:
          • Ahmed Hazem Elsayed Helmi Atwa, BDS

Criterios de participación

Los investigadores buscan personas que se ajusten a una determinada descripción, denominada criterio de elegibilidad. Algunos ejemplos de estos criterios son el estado de salud general de una persona o tratamientos previos.

Criterio de elegibilidad

Edades elegibles para estudiar

  • Adulto
  • Adulto Mayor

Acepta Voluntarios Saludables

No

Descripción

Inclusion Criteria:

  • Completely edentulous patients requiring full-arch implant-supported fixed prosthesis
  • Age 35-70 years
  • Adequate mandibular bone to place at least four implants without major grafting
  • Ability to undergo digital scanning and radiographic evaluation
  • Signed informed consent

Exclusion Criteria:

  • Systemic conditions affecting healing (uncontrolled diabetes, immunosuppression)
  • History of head/neck radiotherapy or bisphosphonate therapy
  • Active oral infection or severe bruxism
  • Strong gag reflex preventing accurate scanning
  • Poor compliance or unwillingness to attend follow-up visits

Plan de estudios

Esta sección proporciona detalles del plan de estudio, incluido cómo está diseñado el estudio y qué mide el estudio.

¿Cómo está diseñado el estudio?

Detalles de diseño

  • Propósito principal: Tratamiento
  • Asignación: Aleatorizado
  • Modelo Intervencionista: Asignación cruzada
  • Enmascaramiento: Ninguno (etiqueta abierta)

Armas e Intervenciones

Grupo de participantes/brazo
Intervención / Tratamiento
Comparador activo: Group I: IO-Connect
Patients received complete-arch implant-supported frameworks fabricated using digital impressions obtained with IO-Connect non-calibrated splinted scan bodies.
Digital impression of the mandibular arch obtained using IO-Connect non-calibrated splinted scan bodies to fabricate the implant-supported framework for Group I.
Comparador activo: Group II: Reverse Scan Body
Patients received complete-arch implant-supported frameworks fabricated using digital impressions obtained with the Reverse Scan Body (RSB) technique.
Digital impression obtained using the Reverse Scan Body (RSB) technique, involving extraoral scanning of scan bodies and superimposition with intraoral tissue scans, to fabricate the implant-supported framework for Group II.
Comparador activo: Group III: Conventional Impression
Patients received complete-arch implant-supported frameworks fabricated using a conventional splinted open-tray impression technique.
Conventional splinted open-tray impression using polyvinyl siloxane material and Type IV dental stone to fabricate the implant-supported framework for Group III.

¿Qué mide el estudio?

Medidas de resultado primarias

Medida de resultado
Medida Descripción
Periodo de tiempo
Passive Fit Assessed by Sheffield One-Screw Test
Periodo de tiempo: The evaluation of passive fit by Sheffield one-screw test will be done 3 months after implant placement (3M-IP), at framework try-in for each of the three impression techniques.
The framework was seated on all implants and a single distal screw was fully tightened; remaining screw sites were examined visually and tactilely for lifting, rocking, or gaps as an indicator of passive fit.
The evaluation of passive fit by Sheffield one-screw test will be done 3 months after implant placement (3M-IP), at framework try-in for each of the three impression techniques.
Passive Fit Assessed by Periapical Radiographs
Periodo de tiempo: The evaluation of passive fit by periapical radiographs will be done 3 months after implant placement, at framework try-in for each of the three impression techniques.
Intraoral periapical radiographs were obtained at each implant site using a paralleling device and evaluated for microgaps at the implant-framework interface.
The evaluation of passive fit by periapical radiographs will be done 3 months after implant placement, at framework try-in for each of the three impression techniques.

Colaboradores e Investigadores

Aquí es donde encontrará personas y organizaciones involucradas en este estudio.

Patrocinador

Investigadores

  • Silla de estudio: Fatma A El-Waseef, PhD, Mansoura University

Fechas de registro del estudio

Estas fechas rastrean el progreso del registro del estudio y los envíos de resultados resumidos a ClinicalTrials.gov. Los registros del estudio y los resultados informados son revisados ​​por la Biblioteca Nacional de Medicina (NLM) para asegurarse de que cumplan con los estándares de control de calidad específicos antes de publicarlos en el sitio web público.

Fechas importantes del estudio

Inicio del estudio (Actual)

25 de enero de 2026

Finalización primaria (Estimado)

25 de octubre de 2026

Finalización del estudio (Estimado)

25 de enero de 2027

Fechas de registro del estudio

Enviado por primera vez

6 de agosto de 2026

Primero enviado que cumplió con los criterios de control de calidad

20 de agosto de 2026

Publicado por primera vez (Actual)

21 de agosto de 2026

Actualizaciones de registros de estudio

Última actualización publicada (Actual)

21 de agosto de 2026

Última actualización enviada que cumplió con los criterios de control de calidad

20 de agosto de 2026

Última verificación

1 de agosto de 2026

Más información

Términos relacionados con este estudio

Plan de datos de participantes individuales (IPD)

¿Planea compartir datos de participantes individuales (IPD)?

INDECISO

Información sobre medicamentos y dispositivos, documentos del estudio

Estudia un producto farmacéutico regulado por la FDA de EE. UU.

No

Estudia un producto de dispositivo regulado por la FDA de EE. UU.

No

Esta información se obtuvo directamente del sitio web clinicaltrials.gov sin cambios. Si tiene alguna solicitud para cambiar, eliminar o actualizar los detalles de su estudio, comuníquese con register@clinicaltrials.gov. Tan pronto como se implemente un cambio en clinicaltrials.gov, también se actualizará automáticamente en nuestro sitio web. .

Suscribir