이 페이지는 자동 번역되었으며 번역의 정확성을 보장하지 않습니다. 참조하십시오 영문판 원본 텍스트의 경우.

Passive Fit of Implant-Supported Frameworks: Digital vs Conventional Impressions

2026년 8월 20일 업데이트: Ahmed Hazem Elsayed Helmi, Mansoura University

Passive Fit Evaluation of Full-Arch Implant-supported Frameworks Using Digital and Conventional Impression Techniques: Crossover Study

This randomized crossover clinical trial compares the passivity of fit of complete-arch mandibular implant-supported frameworks fabricated using three impression techniques: a non-calibrated splinted digital scan body system (IO-Connect), a Reverse Scan Body (RSB) digital impression technique, and a conventional splinted open-tray impression technique. Eight completely edentulous patients each receiving four mandibular implants will be included. Passivity of fit will be evaluated clinically using the Sheffield one-screw test and radiographically using intraoral periapical radiographs obtained with the parallel technique.

연구 개요

상세 설명

Full-arch implant-supported fixed prostheses require a high degree of passive fit to avoid mechanical and biological complications. While digital impression workflows are increasingly used as alternatives to conventional splinted impressions, evidence directly comparing their clinical accuracy for complete-arch implant frameworks remains limited, particularly for the IO-Connect non-calibrated splinting system and the Reverse Scan Body technique.

Eight completely edentulous patients with at least four mandibular implants will be enrolled. Using a crossover design, each patient will undergo all three impression techniques: Group I (IO-Connect splinted scan bodies), Group II (Reverse Scan Body technique), and Group III (conventional splinted open-tray impression with polyvinyl siloxane and Type IV stone casts). For each technique, a corresponding implant-supported framework will be fabricated and evaluated for passivity of fit using the Sheffield one-screw test and periapical radiographs taken with a paralleling device to assess microgaps at the implant-framework interface.

연구 유형

중재적

등록 (추정된)

8

단계

  • 해당 없음

연락처 및 위치

이 섹션에서는 연구를 수행하는 사람들의 연락처 정보와 이 연구가 수행되는 장소에 대한 정보를 제공합니다.

연구 연락처

  • 이름: Ahmed H Hazem Elsayed Helmi Atwa, BDS
  • 전화번호: +20 1092758696
  • 이메일: ahmedhazem@mans.edu.eg

연구 장소

    • Dakahlia Governorate
      • Al Mansurah, Dakahlia Governorate, 이집트
        • 모병
        • Faculty of Dentistry, Mansoura University
        • 연락하다:
        • 수석 연구원:
          • Ahmed Hazem Elsayed Helmi Atwa, BDS

참여기준

연구원은 적격성 기준이라는 특정 설명에 맞는 사람을 찾습니다. 이러한 기준의 몇 가지 예는 개인의 일반적인 건강 상태 또는 이전 치료입니다.

자격 기준

공부할 수 있는 나이

  • 성인
  • 고령자

건강한 자원 봉사자를 받아들입니다

아니

설명

Inclusion Criteria:

  • Completely edentulous patients requiring full-arch implant-supported fixed prosthesis
  • Age 35-70 years
  • Adequate mandibular bone to place at least four implants without major grafting
  • Ability to undergo digital scanning and radiographic evaluation
  • Signed informed consent

Exclusion Criteria:

  • Systemic conditions affecting healing (uncontrolled diabetes, immunosuppression)
  • History of head/neck radiotherapy or bisphosphonate therapy
  • Active oral infection or severe bruxism
  • Strong gag reflex preventing accurate scanning
  • Poor compliance or unwillingness to attend follow-up visits

공부 계획

이 섹션에서는 연구 설계 방법과 연구가 측정하는 내용을 포함하여 연구 계획에 대한 세부 정보를 제공합니다.

연구는 어떻게 설계됩니까?

디자인 세부사항

  • 주 목적: 치료
  • 할당: 무작위
  • 중재 모델: 크로스오버 할당
  • 마스킹: 없음(오픈 라벨)

무기와 개입

참가자 그룹 / 팔
개입 / 치료
활성 비교기: Group I: IO-Connect
Patients received complete-arch implant-supported frameworks fabricated using digital impressions obtained with IO-Connect non-calibrated splinted scan bodies.
Digital impression of the mandibular arch obtained using IO-Connect non-calibrated splinted scan bodies to fabricate the implant-supported framework for Group I.
활성 비교기: Group II: Reverse Scan Body
Patients received complete-arch implant-supported frameworks fabricated using digital impressions obtained with the Reverse Scan Body (RSB) technique.
Digital impression obtained using the Reverse Scan Body (RSB) technique, involving extraoral scanning of scan bodies and superimposition with intraoral tissue scans, to fabricate the implant-supported framework for Group II.
활성 비교기: Group III: Conventional Impression
Patients received complete-arch implant-supported frameworks fabricated using a conventional splinted open-tray impression technique.
Conventional splinted open-tray impression using polyvinyl siloxane material and Type IV dental stone to fabricate the implant-supported framework for Group III.

연구는 무엇을 측정합니까?

주요 결과 측정

결과 측정
측정값 설명
기간
Passive Fit Assessed by Sheffield One-Screw Test
기간: The evaluation of passive fit by Sheffield one-screw test will be done 3 months after implant placement (3M-IP), at framework try-in for each of the three impression techniques.
The framework was seated on all implants and a single distal screw was fully tightened; remaining screw sites were examined visually and tactilely for lifting, rocking, or gaps as an indicator of passive fit.
The evaluation of passive fit by Sheffield one-screw test will be done 3 months after implant placement (3M-IP), at framework try-in for each of the three impression techniques.
Passive Fit Assessed by Periapical Radiographs
기간: The evaluation of passive fit by periapical radiographs will be done 3 months after implant placement, at framework try-in for each of the three impression techniques.
Intraoral periapical radiographs were obtained at each implant site using a paralleling device and evaluated for microgaps at the implant-framework interface.
The evaluation of passive fit by periapical radiographs will be done 3 months after implant placement, at framework try-in for each of the three impression techniques.

공동 작업자 및 조사자

여기에서 이 연구와 관련된 사람과 조직을 찾을 수 있습니다.

수사관

  • 연구 의자: Fatma A El-Waseef, PhD, Mansoura University

연구 기록 날짜

이 날짜는 ClinicalTrials.gov에 대한 연구 기록 및 요약 결과 제출의 진행 상황을 추적합니다. 연구 기록 및 보고된 결과는 공개 웹사이트에 게시되기 전에 특정 품질 관리 기준을 충족하는지 확인하기 위해 국립 의학 도서관(NLM)에서 검토합니다.

연구 주요 날짜

연구 시작 (실제)

2026년 1월 25일

기본 완료 (추정된)

2026년 10월 25일

연구 완료 (추정된)

2027년 1월 25일

연구 등록 날짜

최초 제출

2026년 8월 6일

QC 기준을 충족하는 최초 제출

2026년 8월 20일

처음 게시됨 (실제)

2026년 8월 21일

연구 기록 업데이트

마지막 업데이트 게시됨 (실제)

2026년 8월 21일

QC 기준을 충족하는 마지막 업데이트 제출

2026년 8월 20일

마지막으로 확인됨

2026년 8월 1일

추가 정보

이 연구와 관련된 용어

개별 참가자 데이터(IPD) 계획

개별 참가자 데이터(IPD)를 공유할 계획입니까?

미정

약물 및 장치 정보, 연구 문서

미국 FDA 규제 의약품 연구

아니

미국 FDA 규제 기기 제품 연구

아니

이 정보는 변경 없이 clinicaltrials.gov 웹사이트에서 직접 가져온 것입니다. 귀하의 연구 세부 정보를 변경, 제거 또는 업데이트하도록 요청하는 경우 register@clinicaltrials.gov. 문의하십시오. 변경 사항이 clinicaltrials.gov에 구현되는 즉시 저희 웹사이트에도 자동으로 업데이트됩니다. .

구독하다