Evaluation of Condylar Position After Anterior Mandibular Fracture Fixation Using Plates Versus Headless Compression Screws (fracture)
Comparative Evaluation of Condylar Position Following Anterior Mandibular Fracture Fixation Using Conventional Plates Versus Headless Compression Screws: A Randomized Clinical Trial
This study compares two methods for fixing fractures of the front part of the lower jaw:
Conventional plates and screws Headless compression screws
Patients are randomly assigned to one of the two treatment groups. Researchers will use imaging to see whether either method causes a significant change in the position of the mandibular condyles, which are the parts of the jaw that connect to the jaw joints.
Why it matters: Proper condylar position is important for normal jaw movement, chewing, and overall TMJ function.
Main goal: To determine whether conventional plates or headless compression screws provide better preservation of condylar position after surgery.
The study may help surgeons choose the most appropriate fixation technique for patients with anterior mandibular fractures.
調査の概要
研究の種類
入学 (推定)
段階
- 適用できない
連絡先と場所
研究連絡先
- 名前:ahmed mohamed samy
- 電話番号:01222622431
- メール:ahmed.samy@dentistry.cu.edu.eg
参加基準
適格基準
就学可能な年齢
- 大人
- 高齢者
健康ボランティアの受け入れ
説明
Inclusion Criteria:
- Adult patients of age from 18 years or older, irrespective of the gender.
- Recent single isolated anterior mandibular fracture (symphyseal or parasymphyseal) indicated for open reduction and internal fixation.
- Dentate or partially dentate patients.
Exclusion Criteria:
- Comminuted fractures.
- Medically compromised patients contradicting surgical intervention under general anaesthesia.
- Patients younger than 18 years.
- Completely edentulous patients.
研究計画
研究はどのように設計されていますか?
デザインの詳細
- 主な目的:他の
- 割り当て:ランダム化
- 介入モデル:並列代入
- マスキング:ダブル
武器と介入
参加者グループ / アーム |
介入・治療 |
|---|---|
|
アクティブコンパレータ:コントロール
|
Conventional plate-and-screw fixation has long been considered the standard treatment modality for anterior mandibular fractures.
However, plate fixation may induce transverse mandibular widening or narrowing due to plate adaptation forces, screw placement, and limited interfragmentary compression
|
|
実験的:介入
|
Headless compression screws provide interfragmentary compression along the long axis of the mandible while maintaining a low-profile fixation system.
Their design allows stable fixation with minimal hardware bulk and may reduce unwanted transverse displacement of fracture segments.
|
この研究は何を測定していますか?
主要な結果の測定
結果測定 |
時間枠 |
|---|---|
|
intercondylar angle
時間枠:Postoperative (within one week) and after 3 months
|
Postoperative (within one week) and after 3 months
|
協力者と研究者
スポンサー
研究記録日
主要日程の研究
研究開始 (推定)
一次修了 (推定)
研究の完了 (推定)
試験登録日
最初に提出
QC基準を満たした最初の提出物
最初の投稿 (実際)
学習記録の更新
投稿された最後の更新 (実際)
QC基準を満たした最後の更新が送信されました
最終確認日
詳しくは
本研究に関する用語
その他の研究ID番号
- 2911
個々の参加者データ (IPD) の計画
個々の参加者データ (IPD) を共有する予定はありますか?
医薬品およびデバイス情報、研究文書
米国FDA規制医薬品の研究
米国FDA規制機器製品の研究
米国で製造され、米国から輸出された製品。
この情報は、Web サイト clinicaltrials.gov から変更なしで直接取得したものです。研究の詳細を変更、削除、または更新するリクエストがある場合は、register@clinicaltrials.gov。 までご連絡ください。 clinicaltrials.gov に変更が加えられるとすぐに、ウェブサイトでも自動的に更新されます。