- ICH GCP
- Registre américain des essais cliniques
- Essai clinique NCT07826403
Evaluation of Condylar Position After Anterior Mandibular Fracture Fixation Using Plates Versus Headless Compression Screws (fracture)
Comparative Evaluation of Condylar Position Following Anterior Mandibular Fracture Fixation Using Conventional Plates Versus Headless Compression Screws: A Randomized Clinical Trial
This study compares two methods for fixing fractures of the front part of the lower jaw:
Conventional plates and screws Headless compression screws
Patients are randomly assigned to one of the two treatment groups. Researchers will use imaging to see whether either method causes a significant change in the position of the mandibular condyles, which are the parts of the jaw that connect to the jaw joints.
Why it matters: Proper condylar position is important for normal jaw movement, chewing, and overall TMJ function.
Main goal: To determine whether conventional plates or headless compression screws provide better preservation of condylar position after surgery.
The study may help surgeons choose the most appropriate fixation technique for patients with anterior mandibular fractures.
Aperçu de l'étude
Statut
Les conditions
Intervention / Traitement
Type d'étude
Inscription (Estimé)
Phase
- N'est pas applicable
Contacts et emplacements
Coordonnées de l'étude
- Nom: ahmed mohamed samy
- Numéro de téléphone: 01222622431
- E-mail: ahmed.samy@dentistry.cu.edu.eg
Critères de participation
Critère d'éligibilité
Âges éligibles pour étudier
- Adulte
- Adulte plus âgé
Accepte les volontaires sains
La description
Inclusion Criteria:
- Adult patients of age from 18 years or older, irrespective of the gender.
- Recent single isolated anterior mandibular fracture (symphyseal or parasymphyseal) indicated for open reduction and internal fixation.
- Dentate or partially dentate patients.
Exclusion Criteria:
- Comminuted fractures.
- Medically compromised patients contradicting surgical intervention under general anaesthesia.
- Patients younger than 18 years.
- Completely edentulous patients.
Plan d'étude
Comment l'étude est-elle conçue ?
Détails de conception
- Objectif principal: Autre
- Répartition: Randomisé
- Modèle interventionnel: Affectation parallèle
- Masquage: Double
Armes et Interventions
Groupe de participants / Bras |
Intervention / Traitement |
|---|---|
|
Comparateur actif: contrôle
|
Conventional plate-and-screw fixation has long been considered the standard treatment modality for anterior mandibular fractures.
However, plate fixation may induce transverse mandibular widening or narrowing due to plate adaptation forces, screw placement, and limited interfragmentary compression
|
|
Expérimental: intervention
|
Headless compression screws provide interfragmentary compression along the long axis of the mandible while maintaining a low-profile fixation system.
Their design allows stable fixation with minimal hardware bulk and may reduce unwanted transverse displacement of fracture segments.
|
Que mesure l'étude ?
Principaux critères de jugement
Mesure des résultats |
Délai |
|---|---|
|
intercondylar angle
Délai: Postoperative (within one week) and after 3 months
|
Postoperative (within one week) and after 3 months
|
Collaborateurs et enquêteurs
Parrainer
Dates d'enregistrement des études
Dates principales de l'étude
Début de l'étude (Estimé)
Achèvement primaire (Estimé)
Achèvement de l'étude (Estimé)
Dates d'inscription aux études
Première soumission
Première soumission répondant aux critères de contrôle qualité
Première publication (Réel)
Mises à jour des dossiers d'étude
Dernière mise à jour publiée (Réel)
Dernière mise à jour soumise répondant aux critères de contrôle qualité
Dernière vérification
Plus d'information
Termes liés à cette étude
Autres numéros d'identification d'étude
- 2911
Plan pour les données individuelles des participants (IPD)
Prévoyez-vous de partager les données individuelles des participants (DPI) ?
Informations sur les médicaments et les dispositifs, documents d'étude
Étudie un produit pharmaceutique réglementé par la FDA américaine
Étudie un produit d'appareil réglementé par la FDA américaine
produit fabriqué et exporté des États-Unis.
Ces informations ont été extraites directement du site Web clinicaltrials.gov sans aucune modification. Si vous avez des demandes de modification, de suppression ou de mise à jour des détails de votre étude, veuillez contacter register@clinicaltrials.gov. Dès qu'un changement est mis en œuvre sur clinicaltrials.gov, il sera également mis à jour automatiquement sur notre site Web .