이 페이지는 자동 번역되었으며 번역의 정확성을 보장하지 않습니다. 참조하십시오 영문판 원본 텍스트의 경우.

Airway Deadspace in Children: Air-Q Versus Endotracheal Tube

2020년 3월 25일 업데이트: Wake Forest University Health Sciences

A Prospective Comparison of the Airway Deadspace Associated With the Air-Q® and Endotracheal Tube Using Volumetric Capnography in Young Children

The objective of this study will be to measure the airway deadspace associated with use of appropriately sized an AirQ, a commonly used supraglottic airway in young children weighing between 5 and 20 kg and compare that to the airway deadspace associated with use of an endotracheal tube (ETT) in similarly sized children undergoing controlled ventilation.

연구 개요

상태

완전한

상세 설명

There is an increasing interest in the use of supraglottic airway devices in progressively younger and younger patients. One issue that has not been well evaluated is the contribution of these devices to airway dead space in young children and infants. Volumetric capnography is the only non-invasive technology available at the current time to evaluate airway deadspace. Volumetric capnography essentially monitors the flow of CO2 over time and from the expired waveform one can determine different respiratory parameters including dead space. This is clinically important in young children as the clinician begins to evaluate whether or not to use an endotracheal tube or supraglottic airway in these patients. To perform this investigation the study team will use volumetric capnography to examine the airway dead space associated with these devices during and elective general surgery and urologic procedures in healthy children between the ages of 0 and 6 years of age (roughly 5-20 kg).

Participants in the study will be given ETT or Air-Q as an intervention, but the investigator does not assign specific interventions to the study participants.

연구 유형

관찰

등록 (실제)

62

연락처 및 위치

이 섹션에서는 연구를 수행하는 사람들의 연락처 정보와 이 연구가 수행되는 장소에 대한 정보를 제공합니다.

연구 장소

    • North Carolina
      • Winston-Salem, North Carolina, 미국, 27517
        • Wake Forest Baptist Medical Center

참여기준

연구원은 적격성 기준이라는 특정 설명에 맞는 사람을 찾습니다. 이러한 기준의 몇 가지 예는 개인의 일반적인 건강 상태 또는 이전 치료입니다.

자격 기준

공부할 수 있는 나이

3개월 (어린이)

건강한 자원 봉사자를 받아들입니다

연구 대상 성별

모두

샘플링 방법

비확률 샘플

연구 인구

To perform this investigation we will use volumetric capnography to examine the airway dead space associated with these devices during and elective general surgery and urologic procedures in healthy children between the ages of 0 and 5 years of age (roughly 5-20 kg).

설명

Inclusion Criteria:

  • Patients between the ages of 3 months and 6 years of age weighing between 5 and 20 kg
  • Patient presenting outpatient urologic or general surgery

Exclusion Criteria:

  • History of difficult airway/intubation
  • Patients suspected to have a difficult airway.
  • Morbid obesity BMI >39
  • Emergency status of surgery
  • Patients exposed to second hand smoke
  • Patients with Asthma
  • Patients with a URI symptom such as nasal drainage, cough, or fever within 7 days of the date of surgery
  • History of Prematurity

공부 계획

이 섹션에서는 연구 설계 방법과 연구가 측정하는 내용을 포함하여 연구 계획에 대한 세부 정보를 제공합니다.

연구는 어떻게 설계됩니까?

디자인 세부사항

코호트 및 개입

그룹/코호트
Air-Q 5-9kg
Participants weighing 5-9kg may be chosen to wear the Air-Q device.
Air-Q 10-14kg
Participants weighing 10-14kg may be chosen to wear the Air-Q device.
Air-Q 15-20kg
Participants weighing 15-20kg may be chosen to wear the Air-Q device.
ETT 5-9kg
Participants weighing 5-9kg may be chosen to wear the ETT device.
ETT 10-14kg
Participants weighing 10-14kg may be chosen to wear the ETT device.
ETT 15-20kg
Participants weighing 15-20kg may be chosen to wear the ETT device.

연구는 무엇을 측정합니까?

주요 결과 측정

결과 측정
측정값 설명
기간
Mean Value of Airway Dead Space
기간: 10 minutes
A mean value observed over the first 10 minutes following placement of the ETT or the AirQ at the beginning of the case will be recorded.
10 minutes

2차 결과 측정

결과 측정
측정값 설명
기간
Lung Compliance measured by Respironics NM3 respiratory monitors
기간: 10 minutes
The values of lung compliance will be collected and reported.
10 minutes
Airway Resistance measured by Respironics NM3 respiratory monitors
기간: 10 minutes
The value of resistance to flow in the airways will be collected and reported
10 minutes
Volume of Carbon Dioxide Associated with the Devices
기간: 10 minutes
The volume of carbon dioxide associated with the devices will be recorded and reported.
10 minutes

공동 작업자 및 조사자

여기에서 이 연구와 관련된 사람과 조직을 찾을 수 있습니다.

간행물 및 유용한 링크

연구에 대한 정보 입력을 담당하는 사람이 자발적으로 이러한 간행물을 제공합니다. 이것은 연구와 관련된 모든 것에 관한 것일 수 있습니다.

일반 간행물

연구 기록 날짜

이 날짜는 ClinicalTrials.gov에 대한 연구 기록 및 요약 결과 제출의 진행 상황을 추적합니다. 연구 기록 및 보고된 결과는 공개 웹사이트에 게시되기 전에 특정 품질 관리 기준을 충족하는지 확인하기 위해 국립 의학 도서관(NLM)에서 검토합니다.

연구 주요 날짜

연구 시작 (실제)

2019년 3월 25일

기본 완료 (실제)

2019년 8월 9일

연구 완료 (실제)

2019년 8월 9일

연구 등록 날짜

최초 제출

2018년 12월 19일

QC 기준을 충족하는 최초 제출

2018년 12월 21일

처음 게시됨 (실제)

2018년 12월 24일

연구 기록 업데이트

마지막 업데이트 게시됨 (실제)

2020년 3월 27일

QC 기준을 충족하는 마지막 업데이트 제출

2020년 3월 25일

마지막으로 확인됨

2020년 3월 1일

추가 정보

이 연구와 관련된 용어

기타 연구 ID 번호

  • IRB00055260

개별 참가자 데이터(IPD) 계획

개별 참가자 데이터(IPD)를 공유할 계획입니까?

아니요

약물 및 장치 정보, 연구 문서

미국 FDA 규제 의약품 연구

아니

미국 FDA 규제 기기 제품 연구

아니

미국에서 제조되어 미국에서 수출되는 제품

아니

이 정보는 변경 없이 clinicaltrials.gov 웹사이트에서 직접 가져온 것입니다. 귀하의 연구 세부 정보를 변경, 제거 또는 업데이트하도록 요청하는 경우 register@clinicaltrials.gov. 문의하십시오. 변경 사항이 clinicaltrials.gov에 구현되는 즉시 저희 웹사이트에도 자동으로 업데이트됩니다. .

구독하다