- ICH GCP
- Registro de ensayos clínicos de EE. UU.
- Ensayo clínico NCT03785977
Airway Deadspace in Children: Air-Q Versus Endotracheal Tube
A Prospective Comparison of the Airway Deadspace Associated With the Air-Q® and Endotracheal Tube Using Volumetric Capnography in Young Children
Descripción general del estudio
Estado
Condiciones
Descripción detallada
There is an increasing interest in the use of supraglottic airway devices in progressively younger and younger patients. One issue that has not been well evaluated is the contribution of these devices to airway dead space in young children and infants. Volumetric capnography is the only non-invasive technology available at the current time to evaluate airway deadspace. Volumetric capnography essentially monitors the flow of CO2 over time and from the expired waveform one can determine different respiratory parameters including dead space. This is clinically important in young children as the clinician begins to evaluate whether or not to use an endotracheal tube or supraglottic airway in these patients. To perform this investigation the study team will use volumetric capnography to examine the airway dead space associated with these devices during and elective general surgery and urologic procedures in healthy children between the ages of 0 and 6 years of age (roughly 5-20 kg).
Participants in the study will be given ETT or Air-Q as an intervention, but the investigator does not assign specific interventions to the study participants.
Tipo de estudio
Inscripción (Actual)
Contactos y Ubicaciones
Ubicaciones de estudio
-
-
North Carolina
-
Winston-Salem, North Carolina, Estados Unidos, 27517
- Wake Forest Baptist Medical Center
-
-
Criterios de participación
Criterio de elegibilidad
Edades elegibles para estudiar
Acepta Voluntarios Saludables
Géneros elegibles para el estudio
Método de muestreo
Población de estudio
Descripción
Inclusion Criteria:
- Patients between the ages of 3 months and 6 years of age weighing between 5 and 20 kg
- Patient presenting outpatient urologic or general surgery
Exclusion Criteria:
- History of difficult airway/intubation
- Patients suspected to have a difficult airway.
- Morbid obesity BMI >39
- Emergency status of surgery
- Patients exposed to second hand smoke
- Patients with Asthma
- Patients with a URI symptom such as nasal drainage, cough, or fever within 7 days of the date of surgery
- History of Prematurity
Plan de estudios
¿Cómo está diseñado el estudio?
Detalles de diseño
Cohortes e Intervenciones
Grupo / Cohorte |
|---|
|
Air-Q 5-9kg
Participants weighing 5-9kg may be chosen to wear the Air-Q device.
|
|
Air-Q 10-14kg
Participants weighing 10-14kg may be chosen to wear the Air-Q device.
|
|
Air-Q 15-20kg
Participants weighing 15-20kg may be chosen to wear the Air-Q device.
|
|
ETT 5-9kg
Participants weighing 5-9kg may be chosen to wear the ETT device.
|
|
ETT 10-14kg
Participants weighing 10-14kg may be chosen to wear the ETT device.
|
|
ETT 15-20kg
Participants weighing 15-20kg may be chosen to wear the ETT device.
|
¿Qué mide el estudio?
Medidas de resultado primarias
Medida de resultado |
Medida Descripción |
Periodo de tiempo |
|---|---|---|
|
Mean Value of Airway Dead Space
Periodo de tiempo: 10 minutes
|
A mean value observed over the first 10 minutes following placement of the ETT or the AirQ at the beginning of the case will be recorded.
|
10 minutes
|
Medidas de resultado secundarias
Medida de resultado |
Medida Descripción |
Periodo de tiempo |
|---|---|---|
|
Lung Compliance measured by Respironics NM3 respiratory monitors
Periodo de tiempo: 10 minutes
|
The values of lung compliance will be collected and reported.
|
10 minutes
|
|
Airway Resistance measured by Respironics NM3 respiratory monitors
Periodo de tiempo: 10 minutes
|
The value of resistance to flow in the airways will be collected and reported
|
10 minutes
|
|
Volume of Carbon Dioxide Associated with the Devices
Periodo de tiempo: 10 minutes
|
The volume of carbon dioxide associated with the devices will be recorded and reported.
|
10 minutes
|
Colaboradores e Investigadores
Patrocinador
Publicaciones y enlaces útiles
Publicaciones Generales
- Garcia-Fernandez J, Tusman G, Suarez-Sipmann F, Llorens J, Soro M, Belda JF. Programming pressure support ventilation in pediatric patients in ambulatory surgery with a laryngeal mask airway. Anesth Analg. 2007 Dec;105(6):1585-91, table of contents. doi: 10.1213/01.ane.0000287674.64086.f1.
- Micaglio M, Bonato R, De Nardin M, Parotto M, Trevisanuto D, Zanardo V, Doglioni N, Ori C. Prospective, randomized comparison of ProSeal and Classic laryngeal mask airways in anaesthetized neonates and infants. Br J Anaesth. 2009 Aug;103(2):263-7. doi: 10.1093/bja/aep106. Epub 2009 May 19.
- Templeton TW, Hoke LK, Templeton LB, Ririe DG, Rose DM, Bryan YF. A comparison of 3 ventilation strategies in children younger than 1 year using a Proseal laryngeal mask airway: a randomized controlled trial. J Clin Anesth. 2016 Dec;35:502-508. doi: 10.1016/j.jclinane.2016.07.042. Epub 2016 Oct 19.
- Drake-Brockman TF, Ramgolam A, Zhang G, Hall GL, von Ungern-Sternberg BS. The effect of endotracheal tubes versus laryngeal mask airways on perioperative respiratory adverse events in infants: a randomised controlled trial. Lancet. 2017 Feb 18;389(10070):701-708. doi: 10.1016/S0140-6736(16)31719-6. Epub 2017 Jan 18.
- Casati A, Fanelli G, Torri G. Physiological dead space/tidal volume ratio during face mask, laryngeal mask, and cuffed oropharyngeal airway spontaneous ventilation. J Clin Anesth. 1998 Dec;10(8):652-5. doi: 10.1016/s0952-8180(98)00108-1.
- Templeton TW, Goenaga-Diaz EJ, Templeton LB, Ririe DG. An in vitro analysis of the dead space in 5 supraglottic airway devices intended for use in small children and infants. Paediatr Anaesth. 2018 Jun;28(6):570-572. doi: 10.1111/pan.13382. No abstract available.
- Templeton TW, Hoke LK, Yaung J, Aschenbrenner CA, Rose DM, Templeton LB, Bryan YF. Comparing 3 ventilation modalities by measuring several respiratory parameters using the ProSeal laryngeal mask airway in children. J Clin Anesth. 2016 Nov;34:272-8. doi: 10.1016/j.jclinane.2016.04.031. Epub 2016 May 15.
- Al-Subu A, Jooste E, Hornik CP, Fleming GA, Cheifetz IM, Ofori-Amanfo G. Correlation between minute carbon dioxide elimination and pulmonary blood flow in single-ventricle patients after stage 1 palliation and 2-ventricle patients with intracardiac shunts: A pilot study. Paediatr Anaesth. 2018 Jul;28(7):618-624. doi: 10.1111/pan.13423.
- Ream RS, Schreiner MS, Neff JD, McRae KM, Jawad AF, Scherer PW, Neufeld GR. Volumetric capnography in children. Influence of growth on the alveolar plateau slope. Anesthesiology. 1995 Jan;82(1):64-73. doi: 10.1097/00000542-199501000-00010.
Fechas de registro del estudio
Fechas importantes del estudio
Inicio del estudio (Actual)
Finalización primaria (Actual)
Finalización del estudio (Actual)
Fechas de registro del estudio
Enviado por primera vez
Primero enviado que cumplió con los criterios de control de calidad
Publicado por primera vez (Actual)
Actualizaciones de registros de estudio
Última actualización publicada (Actual)
Última actualización enviada que cumplió con los criterios de control de calidad
Última verificación
Más información
Términos relacionados con este estudio
Palabras clave
Otros números de identificación del estudio
- IRB00055260
Plan de datos de participantes individuales (IPD)
¿Planea compartir datos de participantes individuales (IPD)?
Información sobre medicamentos y dispositivos, documentos del estudio
Estudia un producto farmacéutico regulado por la FDA de EE. UU.
Estudia un producto de dispositivo regulado por la FDA de EE. UU.
producto fabricado y exportado desde los EE. UU.
Esta información se obtuvo directamente del sitio web clinicaltrials.gov sin cambios. Si tiene alguna solicitud para cambiar, eliminar o actualizar los detalles de su estudio, comuníquese con register@clinicaltrials.gov. Tan pronto como se implemente un cambio en clinicaltrials.gov, también se actualizará automáticamente en nuestro sitio web. .