CRUISE System in Flight (CRUISE)
CRUISE Blinded STAT Helicopter Study
This is a prospective, observational, blinded clinical study with the purpose of assessing the safety of a non-invasive decision support system for the identification and management of shock (the CRUISE system). Researchers will compare the recommendations provided by the CRUISE system with those executed as part of the standard of care by transport paramedics and medics in acute ill adult critically ill patients in shock or requiring active resuscitation being transported by helicopter (STAT MedEvac) to Presbyterian Hospital.
Planned total enrollment is 60 patients.
Studie Overzicht
Toestand
Conditie
Gedetailleerde beschrijving
Studietype
Inschrijving (Geschat)
Contacten en locaties
Studiecontact
- Naam: Howard R Stein, MS
- Telefoonnummer: 412-874-9992
- E-mail: hos12@pitt.edu
Studie Contact Back-up
- Naam: Hernando Gomez, MD
- E-mail: gomezh@upmc.edu
Deelname Criteria
Geschiktheidscriteria
Leeftijden die in aanmerking komen voor studie
- Volwassen
- Oudere volwassene
Accepteert gezonde vrijwilligers
Bemonsteringsmethode
Studie Bevolking
Beschrijving
Inclusion Criteria:
- All adult patients with signs of shock evaluated, treated, and/or transported by Emergency Medical Services under medical oversight of UPMC EMS Medical Directors and/or arriving at UPMC facilities with which the PI and Co-investigators routinely have access to the records.
Exclusion Criteria:
- Age < 18 years
- Active atrial fibrillation or irregular rhythm
- Open chest
- Known right ventricular failure
Studie plan
Hoe is de studie opgezet?
Ontwerpdetails
Cohorten en interventies
Groep / Cohort |
Interventie / Behandeling |
|---|---|
|
Observational Blinded Group
|
The sensor device will be removed either by STAT MedEvac personnel or by the investigator after arrival at the hospital.
The patient will receive their standard care upon hospital arrival.
The sensor device will be manually retrieved by the investigator, and deidentified physiological, and waveform data will be loaded to a research server.
Maintain a linkage list to connect this deidentified data back to the original patient.
Prehospital XMLs are downloaded from SQL database as XMLs, they are then processed and appended to STATA tables.
The primary key (PRID) is then linked to the noninvasive monitors with the same key and temporally matched if key is not present.
EHR is linked through secondary keys (MRN and FIN).
Further EHR linkage is done by perfectly matching Protected Health Information (PHI) patient name and date of admission from trauma registry.
An arbitrary study ID variable is created for each subject, and a linkage list is saved along with all other PHI information
|
Wat meet het onderzoek?
Primaire uitkomstmaten
Uitkomstmaat |
Maatregel Beschrijving |
Tijdsspanne |
|---|---|---|
|
CRUISE system decisions Versus Standard Care by Transport decisions - total time to resuscitate
Tijdsspanne: Up to 4 hours of monitoring
|
Measurable Outcome Description: 1.Overall comparison between CRUISE GEN system & Standard Care by Transport paramedics in amount of time spent on resuscitating acute ill adult critically ill patients in shock. Name of Measurement: Total Length of time to resuscitate Measurement Tool: CRUISE Device clock data collected Versus Standard Care Device Clock data collected |
Up to 4 hours of monitoring
|
Medewerkers en onderzoekers
Sponsor
Medewerkers
Onderzoekers
- Hoofdonderzoeker: Hernando Gomez, MD, University of Pittsburgh
Publicaties en nuttige links
Algemene publicaties
- Michard F, Boussat S, Chemla D, Anguel N, Mercat A, Lecarpentier Y, Richard C, Pinsky MR, Teboul JL. Relation between respiratory changes in arterial pulse pressure and fluid responsiveness in septic patients with acute circulatory failure. Am J Respir Crit Care Med. 2000 Jul;162(1):134-8. doi: 10.1164/ajrccm.162.1.9903035.
- Michard F, Chemla D, Richard C, Wysocki M, Pinsky MR, Lecarpentier Y, Teboul JL. Clinical use of respiratory changes in arterial pulse pressure to monitor the hemodynamic effects of PEEP. Am J Respir Crit Care Med. 1999 Mar;159(3):935-9. doi: 10.1164/ajrccm.159.3.9805077.
- Lamia B, Kim HK, Severyn DA, Pinsky MR. Cross-comparisons of trending accuracies of continuous cardiac-output measurements: pulse contour analysis, bioreactance, and pulmonary-artery catheter. J Clin Monit Comput. 2018 Feb;32(1):33-43. doi: 10.1007/s10877-017-9983-4. Epub 2017 Feb 10.
- Ramsey SD, Saint S, Sullivan SD, Dey L, Kelley K, Bowdle A. Clinical and economic effects of pulmonary artery catheterization in nonemergent coronary artery bypass graft surgery. J Cardiothorac Vasc Anesth. 2000 Apr;14(2):113-8. doi: 10.1016/s1053-0770(00)90001-6.
- Food and Drug Administration. "Guidance for industry: oversight of clinical investigations-a risk-based approach to monitoring." Silver Spring, MD: FDA (2013).
- Summers RL, Kolb JC, Woodward LH, Galli RL. Differentiating systolic from diastolic heart failure using impedance cardiography. Acad Emerg Med. 1999 Jul;6(7):693-9. doi: 10.1111/j.1553-2712.1999.tb00437.x.
- Summers RL, Kolb JC, Woodward LH, Galli RL. Diagnostic uses for thoracic electrical bioimpedance in the emergency department: clinical case series. Eur J Emerg Med. 1999 Sep;6(3):193-9. doi: 10.1097/00063110-199909000-00004.
- Siegel LC, Shafer SL, Martinez GM, Ream AK, Scott JC. Simultaneous measurements of cardiac output by thermodilution, esophageal Doppler, and electrical impedance in anesthetized patients. J Cardiothorac Anesth. 1988 Oct;2(5):590-5. doi: 10.1016/0888-6296(88)90049-x.
- Connors AF Jr, Speroff T, Dawson NV, Thomas C, Harrell FE Jr, Wagner D, Desbiens N, Goldman L, Wu AW, Califf RM, Fulkerson WJ Jr, Vidaillet H, Broste S, Bellamy P, Lynn J, Knaus WA. The effectiveness of right heart catheterization in the initial care of critically ill patients. SUPPORT Investigators. JAMA. 1996 Sep 18;276(11):889-97. doi: 10.1001/jama.276.11.889.
Studie record data
Bestudeer belangrijke data
Studie start (Geschat)
Primaire voltooiing (Geschat)
Studie voltooiing (Geschat)
Studieregistratiedata
Eerst ingediend
Eerst ingediend dat voldeed aan de QC-criteria
Eerst geplaatst (Werkelijk)
Updates van studierecords
Laatste update geplaatst (Werkelijk)
Laatste update ingediend die voldeed aan QC-criteria
Laatst geverifieerd
Meer informatie
Termen gerelateerd aan deze studie
Trefwoorden
Aanvullende relevante MeSH-voorwaarden
Andere studie-ID-nummers
- STUDY25080077
- HT942524C0121 (Ander subsidie-/financieringsnummer: Combat Casualty Care Research Program (CCCRP))
Plan Individuele Deelnemersgegevens (IPD)
Bent u van plan om gegevens van individuele deelnemers (IPD) te delen?
Beschrijving IPD-plan
Informatie over medicijnen en apparaten, studiedocumenten
Bestudeert een door de Amerikaanse FDA gereguleerd geneesmiddel
Bestudeert een door de Amerikaanse FDA gereguleerd apparaatproduct
product vervaardigd in en geëxporteerd uit de V.S.
Deze informatie is zonder wijzigingen rechtstreeks van de website clinicaltrials.gov gehaald. Als u verzoeken heeft om uw onderzoeksgegevens te wijzigen, te verwijderen of bij te werken, neem dan contact op met register@clinicaltrials.gov. Zodra er een wijziging wordt doorgevoerd op clinicaltrials.gov, wordt deze ook automatisch bijgewerkt op onze website .