- ICH GCP
- Реестр клинических исследований США
- Клиническое испытание NCT07637240
CRUISE System in Flight (CRUISE)
CRUISE Blinded STAT Helicopter Study
This is a prospective, observational, blinded clinical study with the purpose of assessing the safety of a non-invasive decision support system for the identification and management of shock (the CRUISE system). Researchers will compare the recommendations provided by the CRUISE system with those executed as part of the standard of care by transport paramedics and medics in acute ill adult critically ill patients in shock or requiring active resuscitation being transported by helicopter (STAT MedEvac) to Presbyterian Hospital.
Planned total enrollment is 60 patients.
Обзор исследования
Статус
Условия
Подробное описание
Тип исследования
Регистрация (Оцененный)
Контакты и местонахождение
Контакты исследования
- Имя: Howard R Stein, MS
- Номер телефона: 412-874-9992
- Электронная почта: hos12@pitt.edu
Учебное резервное копирование контактов
- Имя: Hernando Gomez, MD
- Электронная почта: gomezh@upmc.edu
Критерии участия
Критерии приемлемости
Возраст, подходящий для обучения
- Взрослый
- Пожилой взрослый
Принимает здоровых добровольцев
Метод выборки
Исследуемая популяция
Описание
Inclusion Criteria:
- All adult patients with signs of shock evaluated, treated, and/or transported by Emergency Medical Services under medical oversight of UPMC EMS Medical Directors and/or arriving at UPMC facilities with which the PI and Co-investigators routinely have access to the records.
Exclusion Criteria:
- Age < 18 years
- Active atrial fibrillation or irregular rhythm
- Open chest
- Known right ventricular failure
Учебный план
Как устроено исследование?
Детали дизайна
Когорты и вмешательства
Группа / когорта |
Вмешательство/лечение |
|---|---|
|
Observational Blinded Group
|
The sensor device will be removed either by STAT MedEvac personnel or by the investigator after arrival at the hospital.
The patient will receive their standard care upon hospital arrival.
The sensor device will be manually retrieved by the investigator, and deidentified physiological, and waveform data will be loaded to a research server.
Maintain a linkage list to connect this deidentified data back to the original patient.
Prehospital XMLs are downloaded from SQL database as XMLs, they are then processed and appended to STATA tables.
The primary key (PRID) is then linked to the noninvasive monitors with the same key and temporally matched if key is not present.
EHR is linked through secondary keys (MRN and FIN).
Further EHR linkage is done by perfectly matching Protected Health Information (PHI) patient name and date of admission from trauma registry.
An arbitrary study ID variable is created for each subject, and a linkage list is saved along with all other PHI information
|
Что измеряет исследование?
Первичные показатели результатов
Мера результата |
Мера Описание |
Временное ограничение |
|---|---|---|
|
CRUISE system decisions Versus Standard Care by Transport decisions - total time to resuscitate
Временное ограничение: Up to 4 hours of monitoring
|
Measurable Outcome Description: 1.Overall comparison between CRUISE GEN system & Standard Care by Transport paramedics in amount of time spent on resuscitating acute ill adult critically ill patients in shock. Name of Measurement: Total Length of time to resuscitate Measurement Tool: CRUISE Device clock data collected Versus Standard Care Device Clock data collected |
Up to 4 hours of monitoring
|
Соавторы и исследователи
Спонсор
Соавторы
Следователи
- Главный следователь: Hernando Gomez, MD, University of Pittsburgh
Публикации и полезные ссылки
Общие публикации
- Michard F, Boussat S, Chemla D, Anguel N, Mercat A, Lecarpentier Y, Richard C, Pinsky MR, Teboul JL. Relation between respiratory changes in arterial pulse pressure and fluid responsiveness in septic patients with acute circulatory failure. Am J Respir Crit Care Med. 2000 Jul;162(1):134-8. doi: 10.1164/ajrccm.162.1.9903035.
- Michard F, Chemla D, Richard C, Wysocki M, Pinsky MR, Lecarpentier Y, Teboul JL. Clinical use of respiratory changes in arterial pulse pressure to monitor the hemodynamic effects of PEEP. Am J Respir Crit Care Med. 1999 Mar;159(3):935-9. doi: 10.1164/ajrccm.159.3.9805077.
- Lamia B, Kim HK, Severyn DA, Pinsky MR. Cross-comparisons of trending accuracies of continuous cardiac-output measurements: pulse contour analysis, bioreactance, and pulmonary-artery catheter. J Clin Monit Comput. 2018 Feb;32(1):33-43. doi: 10.1007/s10877-017-9983-4. Epub 2017 Feb 10.
- Ramsey SD, Saint S, Sullivan SD, Dey L, Kelley K, Bowdle A. Clinical and economic effects of pulmonary artery catheterization in nonemergent coronary artery bypass graft surgery. J Cardiothorac Vasc Anesth. 2000 Apr;14(2):113-8. doi: 10.1016/s1053-0770(00)90001-6.
- Food and Drug Administration. "Guidance for industry: oversight of clinical investigations-a risk-based approach to monitoring." Silver Spring, MD: FDA (2013).
- Summers RL, Kolb JC, Woodward LH, Galli RL. Differentiating systolic from diastolic heart failure using impedance cardiography. Acad Emerg Med. 1999 Jul;6(7):693-9. doi: 10.1111/j.1553-2712.1999.tb00437.x.
- Summers RL, Kolb JC, Woodward LH, Galli RL. Diagnostic uses for thoracic electrical bioimpedance in the emergency department: clinical case series. Eur J Emerg Med. 1999 Sep;6(3):193-9. doi: 10.1097/00063110-199909000-00004.
- Siegel LC, Shafer SL, Martinez GM, Ream AK, Scott JC. Simultaneous measurements of cardiac output by thermodilution, esophageal Doppler, and electrical impedance in anesthetized patients. J Cardiothorac Anesth. 1988 Oct;2(5):590-5. doi: 10.1016/0888-6296(88)90049-x.
- Connors AF Jr, Speroff T, Dawson NV, Thomas C, Harrell FE Jr, Wagner D, Desbiens N, Goldman L, Wu AW, Califf RM, Fulkerson WJ Jr, Vidaillet H, Broste S, Bellamy P, Lynn J, Knaus WA. The effectiveness of right heart catheterization in the initial care of critically ill patients. SUPPORT Investigators. JAMA. 1996 Sep 18;276(11):889-97. doi: 10.1001/jama.276.11.889.
Даты записи исследования
Изучение основных дат
Начало исследования (Оцененный)
Первичное завершение (Оцененный)
Завершение исследования (Оцененный)
Даты регистрации исследования
Первый отправленный
Впервые представлено, что соответствует критериям контроля качества
Первый опубликованный (Действительный)
Обновления учебных записей
Последнее опубликованное обновление (Действительный)
Последнее отправленное обновление, отвечающее критериям контроля качества
Последняя проверка
Дополнительная информация
Термины, связанные с этим исследованием
Ключевые слова
Дополнительные соответствующие термины MeSH
Другие идентификационные номера исследования
- STUDY25080077
- HT942524C0121 (Другой номер гранта/финансирования: Combat Casualty Care Research Program (CCCRP))
Планирование данных отдельных участников (IPD)
Планируете делиться данными об отдельных участниках (IPD)?
Описание плана IPD
Информация о лекарствах и устройствах, исследовательские документы
Изучает лекарственный продукт, регулируемый FDA США.
Изучает продукт устройства, регулируемый Управлением по санитарному надзору за качеством пищевых продуктов и медикаментов США.
продукт, произведенный в США и экспортированный из США.
Эта информация была получена непосредственно с веб-сайта clinicaltrials.gov без каких-либо изменений. Если у вас есть запросы на изменение, удаление или обновление сведений об исследовании, обращайтесь по адресу register@clinicaltrials.gov. Как только изменение будет реализовано на clinicaltrials.gov, оно будет автоматически обновлено и на нашем веб-сайте. .