Relationship Between Optimal Laryngeal Mask Airway Cuff Volume and Physical Examination of Head and Neck (RCVPE)
Prediction of Optimal Laryngeal Mask Airway Cuff Volume From Parameters of Physical Examination of Head and Neck
Studieoversikt
Detaljert beskrivelse
Overinflation of laryngeal mask airway cuff can induce side effects like hoarseness, vocal cord paralysis, sorethroat. Some study revealed that 60cmH2O of intracuff pressure is maximum pressure which is not increase side effect.
The manufacturer recommends that the cuff is inflated with the minimum volume of air required to provide an effective seal(max volume - size 3, 20 ml; size 4, 30 ml; size 5, 40).
The investigators will measure anatomical structure (neck circumference, neck length, thyroid-mental distance, etc.) which can influence cuff volume and pressure and find correlation between cuff volume and physical figure measured.
Studietype
Registrering (Faktiske)
Fase
- Ikke aktuelt
Kontakter og plasseringer
Studiesteder
-
-
-
Seoul, Korea, Republikken, 136705
- Korea University Anam Hospital
-
-
Deltakelseskriterier
Kvalifikasjonskriterier
Alder som er kvalifisert for studier
Tar imot friske frivillige
Kjønn som er kvalifisert for studier
Beskrivelse
Inclusion Criteria:
- Adult (age 19-65)
- American Society of Anesthesiology Classification I-III
Exclusion Criteria:
- cardiovascular disease, cerebrovascular disease, pulmonary disease
- patient who have operation history for airway
- patient who expected difficult intubation
- patient who have risk of aspiration
Studieplan
Hvordan er studiet utformet?
Designdetaljer
- Primært formål: Screening
- Tildeling: N/A
- Intervensjonsmodell: Enkeltgruppeoppdrag
- Masking: Ingen (Open Label)
Våpen og intervensjoner
Deltakergruppe / Arm |
Intervensjon / Behandling |
|---|---|
|
Annen: Classic laryngeal mask airway
single arm
|
|
Hva måler studien?
Primære resultatmål
Resultatmål |
Tiltaksbeskrivelse |
Tidsramme |
|---|---|---|
|
optimal laryngeal mask airway cuff volume
Tidsramme: 20minutes
|
◦The investigators remove air until gas leak occured around the cuff under airway pressure 15cm H20, fresh gas flow 6liters/min.
Check the volume and pressure just before leakage occured.
|
20minutes
|
Samarbeidspartnere og etterforskere
Sponsor
Etterforskere
- Studieleder: Hye-Won Shin, MD, PhD, Department of anesthesiology and pain medicine, Korea University Anam Hospital
Studierekorddatoer
Studer hoveddatoer
Studiestart
Primær fullføring (Faktiske)
Studiet fullført (Faktiske)
Datoer for studieregistrering
Først innsendt
Først innsendt som oppfylte QC-kriteriene
Først lagt ut (Anslag)
Oppdateringer av studieposter
Sist oppdatering lagt ut (Anslag)
Siste oppdatering sendt inn som oppfylte QC-kriteriene
Sist bekreftet
Mer informasjon
Begreper knyttet til denne studien
Nøkkelord
Andre studie-ID-numre
- LMA60
Plan for individuelle deltakerdata (IPD)
Planlegger du å dele individuelle deltakerdata (IPD)?
Denne informasjonen ble hentet direkte fra nettstedet clinicaltrials.gov uten noen endringer. Hvis du har noen forespørsler om å endre, fjerne eller oppdatere studiedetaljene dine, vennligst kontakt register@clinicaltrials.gov. Så snart en endring er implementert på clinicaltrials.gov, vil denne også bli oppdatert automatisk på nettstedet vårt. .