Denne siden ble automatisk oversatt og nøyaktigheten av oversettelsen er ikke garantert. Vennligst referer til engelsk versjon for en kildetekst.

Mandibular and Mental Index in Implant Prosthetic Restorations

23. mai 2026 oppdatert av: Zeynep AKGÜL, Abant Izzet Baysal University

Evaluation of Mandibular Radiomorphometric Indices in Implant Patients With Different Prosthetic Restorations

This retrospective longitudinal observational study evaluates mandibular radiomorphometric indices in patients rehabilitated with different implant-supported prosthetic restorations. Clinical and panoramic radiographic records of adult patients with dental implants were retrospectively reviewed. Mandibular index and mental index measurements were obtained from panoramic radiographs taken at baseline after prosthetic loading, 6 months after loading, and 1.5 years after loading. The study aims to assess changes in these radiomorphometric parameters over time and to determine whether patient-, implant-, and prosthesis-related factors are associated with mandibular cortical bone-related measurements.

Studieoversikt

Status

Fullført

Studietype

Observasjonsmessig

Registrering (Faktiske)

186

Kontakter og plasseringer

Denne delen inneholder kontaktinformasjon for de som utfører studien, og informasjon om hvor denne studien blir utført.

Studiesteder

    • Central
      • Bolu, Central, Tyrkia (Türkiye), 14100
        • Faculty of Dentistry, Bolu Abant İzzet Baysal University, Department of Periodontics

Deltakelseskriterier

Forskere ser etter personer som passer til en bestemt beskrivelse, kalt kvalifikasjonskriterier. Noen eksempler på disse kriteriene er en persons generelle helsetilstand eller tidligere behandlinger.

Kvalifikasjonskriterier

Alder som er kvalifisert for studier

  • Barn
  • Voksen
  • Eldre voksen

Tar imot friske frivillige

N/A

Prøvetakingsmetode

Ikke-sannsynlighetsprøve

Studiepopulasjon

The study population consisted of adult patients who received implant-supported prosthetic rehabilitation at Bolu Abant Izzet Baysal University Faculty of Dentistry and had complete clinical and panoramic radiographic records at baseline after prosthetic loading, 6 months after loading, and 1.5 years after loading.

Beskrivelse

Inclusion Criteria:

  • Patients aged 18 years or older
  • Patients with at least one osseointegrated dental implant restored with an implant-supported prosthetic restoration
  • Availability of panoramic radiographs at baseline after prosthetic loading, 6 months after loading, and 1.5 years after loading
  • Complete demographic, clinical, implant-related, prosthetic, and radiographic records

Exclusion Criteria:

  • Patients with uncontrolled systemic disease
  • Use of medications that may affect bone metabolism
  • History of radiotherapy to the head and neck region
  • Implant loss during the follow-up period
  • Insufficient panoramic radiographic image quality for radiomorphometric measurements
  • Incomplete clinical or radiographic records

Studieplan

Denne delen gir detaljer om studieplanen, inkludert hvordan studien er utformet og hva studien måler.

Hvordan er studiet utformet?

Designdetaljer

Kohorter og intervensjoner

Gruppe / Kohort
Single Crown Group
Patients rehabilitated with implant-supported single-crown restorations.
Fixed Partial Denture Group
Patients rehabilitated with implant-supported fixed partial denture or bridge restorations.
Removable Prosthesis Group
Patients rehabilitated with implant-supported removable prostheses.
Full-mouth Fixed Restoration Group
Patients rehabilitated with implant-supported full-mouth fixed restorations.
Splinted Crown Group
Patients rehabilitated with implant-supported splinted crown restorations.

Hva måler studien?

Primære resultatmål

Resultatmål
Tiltaksbeskrivelse
Tidsramme
Change in Mandibular Index Values Over Time
Tidsramme: Baseline after prosthetic loading, 6 months after loading, and 1.5 years after loading
Mandibular index values measured on panoramic radiographs will be evaluated at baseline after prosthetic loading, 6 months after loading, and 1.5 years after loading to assess longitudinal changes in mandibular cortical bone-related radiomorphometric parameters.
Baseline after prosthetic loading, 6 months after loading, and 1.5 years after loading

Sekundære resultatmål

Resultatmål
Tiltaksbeskrivelse
Tidsramme
Change in Mental Index Values Over Time
Tidsramme: Baseline after prosthetic loading, 6 months after loading, and 1.5 years after loading
Mental index values measured on panoramic radiographs will be evaluated at baseline after prosthetic loading, 6 months after loading, and 1.5 years after loading to assess longitudinal changes in mandibular cortical bone-related radiomorphometric parameters.
Baseline after prosthetic loading, 6 months after loading, and 1.5 years after loading
Association Between Prosthetic Restoration Type and Mandibular Index Values
Tidsramme: 6 months and 1.5 years after prosthetic loading
Mandibular index values will be compared among patients rehabilitated with different implant-supported prosthetic restoration types, including single crowns, fixed partial dentures, removable prostheses, full-mouth fixed restorations, and splinted crowns.
6 months and 1.5 years after prosthetic loading

Samarbeidspartnere og etterforskere

Det er her du vil finne personer og organisasjoner som er involvert i denne studien.

Studierekorddatoer

Disse datoene sporer fremdriften for innsending av studieposter og sammendragsresultater til ClinicalTrials.gov. Studieposter og rapporterte resultater gjennomgås av National Library of Medicine (NLM) for å sikre at de oppfyller spesifikke kvalitetskontrollstandarder før de legges ut på det offentlige nettstedet.

Studer hoveddatoer

Studiestart (Faktiske)

15. november 2025

Primær fullføring (Faktiske)

15. april 2026

Studiet fullført (Faktiske)

15. mai 2026

Datoer for studieregistrering

Først innsendt

23. mai 2026

Først innsendt som oppfylte QC-kriteriene

23. mai 2026

Først lagt ut (Faktiske)

29. mai 2026

Oppdateringer av studieposter

Sist oppdatering lagt ut (Faktiske)

29. mai 2026

Siste oppdatering sendt inn som oppfylte QC-kriteriene

23. mai 2026

Sist bekreftet

1. mai 2026

Mer informasjon

Begreper knyttet til denne studien

Andre studie-ID-numre

  • BAİBU-Perio-ZA-02

Plan for individuelle deltakerdata (IPD)

Planlegger du å dele individuelle deltakerdata (IPD)?

NEI

Legemiddel- og utstyrsinformasjon, studiedokumenter

Studerer et amerikansk FDA-regulert medikamentprodukt

Nei

Studerer et amerikansk FDA-regulert enhetsprodukt

Nei

Denne informasjonen ble hentet direkte fra nettstedet clinicaltrials.gov uten noen endringer. Hvis du har noen forespørsler om å endre, fjerne eller oppdatere studiedetaljene dine, vennligst kontakt register@clinicaltrials.gov. Så snart en endring er implementert på clinicaltrials.gov, vil denne også bli oppdatert automatisk på nettstedet vårt. .

Abonnere