- ICH GCP
- US Clinical Trials Registry
- Klinisk utprøving NCT07704788
Two Dimensional Versus Three Dimensional Transvaginal U/S With or Without SIS
Two Dimensional Versus Three Dimensional Transvaginal U/S With or Without SIS for the Evaluation of Cesarean Scar Defect
Primary aim:
To assess the diagnostic agreement between 2D vs 3D TV U/S with or without SIS for the evaluation of cesarean scar defects and its correlation with symptoms.
Secondary aims:
To assess the relation between the size of the niche and the patient symptoms.
Studieoversikt
Status
Forhold
Detaljert beskrivelse
Primary aim:
To assess the diagnostic agreement between 2D vs 3D TV U/S with or without SIS for the evaluation of cesarean scar defects and its correlation with symptoms. To compare both imaging modalities regarding assessment of cesarean scar defect parameters, including depth, length, width, anterior myometrial thickness, and residual myometrial thickness, as well as to evaluate procedure time, patient tolerability, and satisfaction.
Secondary aims:
To assess the relation between the size of the niche and the patient symptoms.
Studietype
Registrering (Antatt)
Kontakter og plasseringer
Studiekontakt
- Navn: Emam Mohamed Sayed Emam Mohamed Sayed
- Telefonnummer: 01095877078
- E-post: emammohammed.12345@gmail.com
Deltakelseskriterier
Kvalifikasjonskriterier
Alder som er kvalifisert for studier
- Voksen
Tar imot friske frivillige
Prøvetakingsmetode
Studiepopulasjon
Beskrivelse
Inclusion criteria:
- Women aged 20-45 years
- History of at least one previous cesarean section
- Interval since last cesarean section ranging from 6 months to 10 years
- Willingness to participate and provide written informed consent
Exclusion criteria:
- Current pregnancy
- Active pelvic infection or acute pelvic inflammatory disease
- Large uterine fibroids distorting the uterine cavity
- History of uterine surgery other than cesarean section (e.g., myomectomy)
- Failure of SIS performance
- Patients on any contraception methods
Studieplan
Hvordan er studiet utformet?
Designdetaljer
Kohorter og intervensjoner
Gruppe / Kohort |
|---|
|
scar niche patients
|
Hva måler studien?
Primære resultatmål
Resultatmål |
Tidsramme |
|---|---|
|
Diagnostic agreement between 3D-TVUS and SIS in detecting cesarean scar defects, assessed using Cohen's kappa coefficient
Tidsramme: 1 hour
|
1 hour
|
Samarbeidspartnere og etterforskere
Sponsor
Studierekorddatoer
Studer hoveddatoer
Studiestart (Antatt)
Primær fullføring (Antatt)
Studiet fullført (Antatt)
Datoer for studieregistrering
Først innsendt
Først innsendt som oppfylte QC-kriteriene
Først lagt ut (Faktiske)
Oppdateringer av studieposter
Sist oppdatering lagt ut (Faktiske)
Siste oppdatering sendt inn som oppfylte QC-kriteriene
Sist bekreftet
Mer informasjon
Begreper knyttet til denne studien
Nøkkelord
Andre studie-ID-numre
- Soh-Med-26-6-22MS
Plan for individuelle deltakerdata (IPD)
Planlegger du å dele individuelle deltakerdata (IPD)?
Legemiddel- og utstyrsinformasjon, studiedokumenter
Studerer et amerikansk FDA-regulert medikamentprodukt
Studerer et amerikansk FDA-regulert enhetsprodukt
Denne informasjonen ble hentet direkte fra nettstedet clinicaltrials.gov uten noen endringer. Hvis du har noen forespørsler om å endre, fjerne eller oppdatere studiedetaljene dine, vennligst kontakt register@clinicaltrials.gov. Så snart en endring er implementert på clinicaltrials.gov, vil denne også bli oppdatert automatisk på nettstedet vårt. .