- ICH GCP
- Rejestr badań klinicznych w USA
- Badanie kliniczne NCT00371839
Clinical Applications for Time-Compressed Speech Tests
The purpose of this study is to determine the effects of age-related cognitive changes on hearing aid benefit based on hearing aid compression time constants.
The hypothesis is that people with poor working memory skills will benefit from slow time constants in hearing aid compression while those with good working memory skills will be able to benefit from more sophisticated compression algorithms with rapid time constants.
Przegląd badań
Szczegółowy opis
Recent research has shown the relevance of cognitive function in hearing aid evaluation and the sensitivity of the aging auditory system to temporal distortions. The proposed investigation will examine the interaction of working memory and hearing aid compression method on speech recognition in background competition for older listeners. This interaction will be investigated for the following three forms of background competition:
- Competition from continuous speech-shaped noise.
- Competition from speech-modulated noise.
- Competition from a single interfering talker.
The goals of the study will be accomplished in two phases. In the first phase, 160 adults aged 50 through 75 years will be evaluated on a battery of tests to determine their cognitive capacity, time-compressed speech scores and their candidacy for inclusion in the second phase of the study. At the conclusion of this phase of testing, the participants will be divided into three groups:
- subjects with TCS test scores in the highest quartile (the HIGH group)
- subjects with TCS test scores in the lowest quartile (the LOW group)
- the remaining listeners
The second phase of the experiment will include listeners from the HIGH and LOW groups only. These subjects will be evaluated with respect to their speech recognition ability for three types of interference (steady-state noise, speech-modulated noise, single interfering talker). The HINT test (Nilsson, Soli, & Sumida, 1995; Nilsson et al., 1994) will be used to obtain the signal-to-noise ratio (SNR) at 50% recognition for the three masking conditions for each of three types of amplification:
- one- channel linear amplification (LINEAR) with frequency shaping
- two-channel wide dynamic range compression with fast time constants (FAST)
- two-channel wide dynamic range compression with slow time constants (SLOW) Listener groups will be compared across hearing aid conditions and across background interference conditions.
Typ studiów
Zapisy (Rzeczywisty)
Faza
- Nie dotyczy
Kryteria uczestnictwa
Kryteria kwalifikacji
Wiek uprawniający do nauki
Akceptuje zdrowych ochotników
Płeć kwalifikująca się do nauki
Opis
Inclusion Criteria:
- Participants will be 50 to 75 years old.
- Hearing loss will be limited to 40 dB HL from 250 Hz through 1000 Hz, and to 60 dB HL through 4000 Hz.
- Hearing loss must be greater than 25 dB at two or more frequencies from 250 to 4000 Hz.
Exclusion Criteria:
- None of the participants will be current or past hearing aid users; all will be free of ear disease.
- Participants with conductive hearing losses, defined as air-bone gap greater than 15 dB, will be excluded.
- The audiometric battery with acoustic reflex thresholds and decay measurements will be used to exclude anyone with evidence of a central disorder or a pathology other than a sensorineural loss. Those potential participants will be referred to a medical professional.
Plan studiów
Jak projektuje się badanie?
Szczegóły projektu
- Główny cel: Leczenie
- Przydział: Nielosowe
- Model interwencyjny: Przydział równoległy
- Maskowanie: Brak (otwarta etykieta)
Broń i interwencje
Grupa uczestników / Arm |
Interwencja / Leczenie |
|---|---|
|
Aktywny komparator: Mild Hearing Loss
Audiological Evaluation will show average hearing threshold at 500, 1000, 2000, and 4000 Hz of 20-39 decibels hearing level (dBHL)
|
Tests of hearing, cognition, and speech perception
|
|
Aktywny komparator: Moderate Hearing Loss
Audiological Evaluation will show average hearing threshold at 500, 1000, 2000, and 4000 Hz of 40-49 decibels hearing level (dBHL)
|
Tests of hearing, cognition, and speech perception
|
|
Aktywny komparator: Moderate-Severe Hearing Loss
Audiological Evaluation will show average hearing threshold at 500, 1000, 2000, and 4000 Hz greater than 50 decibels hearing level (dBHL)
|
Tests of hearing, cognition, and speech perception
|
Co mierzy badanie?
Podstawowe miary wyniku
Miara wyniku |
Opis środka |
Ramy czasowe |
|---|---|---|
|
Ability to Understand Speech in Noise Background
Ramy czasowe: one year
|
Measure speech perception for sentences in background noise
|
one year
|
Współpracownicy i badacze
Śledczy
- Główny śledczy: Marjorie R. Leek, PhD, VA Loma Linda Healthcare System, Loma Linda, CA
Publikacje i pomocne linki
Daty zapisu na studia
Główne daty studiów
Rozpoczęcie studiów
Zakończenie podstawowe (Rzeczywisty)
Ukończenie studiów (Rzeczywisty)
Daty rejestracji na studia
Pierwszy przesłany
Pierwszy przesłany, który spełnia kryteria kontroli jakości
Pierwszy wysłany (Oszacować)
Aktualizacje rekordów badań
Ostatnia wysłana aktualizacja (Oszacować)
Ostatnia przesłana aktualizacja, która spełniała kryteria kontroli jakości
Ostatnia weryfikacja
Więcej informacji
Terminy związane z tym badaniem
Dodatkowe istotne warunki MeSH
Inne numery identyfikacyjne badania
- C4338-R
Informacje o lekach i urządzeniach, dokumenty badawcze
Bada produkt leczniczy regulowany przez amerykańską FDA
Bada produkt urządzenia regulowany przez amerykańską FDA
produkt wyprodukowany i wyeksportowany z USA
Te informacje zostały pobrane bezpośrednio ze strony internetowej clinicaltrials.gov bez żadnych zmian. Jeśli chcesz zmienić, usunąć lub zaktualizować dane swojego badania, skontaktuj się z register@clinicaltrials.gov. Gdy tylko zmiana zostanie wprowadzona na stronie clinicaltrials.gov, zostanie ona automatycznie zaktualizowana również na naszej stronie internetowej .