- ICH GCP
- Registro de ensayos clínicos de EE. UU.
- Ensayo clínico NCT00371839
Clinical Applications for Time-Compressed Speech Tests
The purpose of this study is to determine the effects of age-related cognitive changes on hearing aid benefit based on hearing aid compression time constants.
The hypothesis is that people with poor working memory skills will benefit from slow time constants in hearing aid compression while those with good working memory skills will be able to benefit from more sophisticated compression algorithms with rapid time constants.
Descripción general del estudio
Estado
Condiciones
Intervención / Tratamiento
Descripción detallada
Recent research has shown the relevance of cognitive function in hearing aid evaluation and the sensitivity of the aging auditory system to temporal distortions. The proposed investigation will examine the interaction of working memory and hearing aid compression method on speech recognition in background competition for older listeners. This interaction will be investigated for the following three forms of background competition:
- Competition from continuous speech-shaped noise.
- Competition from speech-modulated noise.
- Competition from a single interfering talker.
The goals of the study will be accomplished in two phases. In the first phase, 160 adults aged 50 through 75 years will be evaluated on a battery of tests to determine their cognitive capacity, time-compressed speech scores and their candidacy for inclusion in the second phase of the study. At the conclusion of this phase of testing, the participants will be divided into three groups:
- subjects with TCS test scores in the highest quartile (the HIGH group)
- subjects with TCS test scores in the lowest quartile (the LOW group)
- the remaining listeners
The second phase of the experiment will include listeners from the HIGH and LOW groups only. These subjects will be evaluated with respect to their speech recognition ability for three types of interference (steady-state noise, speech-modulated noise, single interfering talker). The HINT test (Nilsson, Soli, & Sumida, 1995; Nilsson et al., 1994) will be used to obtain the signal-to-noise ratio (SNR) at 50% recognition for the three masking conditions for each of three types of amplification:
- one- channel linear amplification (LINEAR) with frequency shaping
- two-channel wide dynamic range compression with fast time constants (FAST)
- two-channel wide dynamic range compression with slow time constants (SLOW) Listener groups will be compared across hearing aid conditions and across background interference conditions.
Tipo de estudio
Inscripción (Actual)
Fase
- No aplica
Criterios de participación
Criterio de elegibilidad
Edades elegibles para estudiar
Acepta Voluntarios Saludables
Géneros elegibles para el estudio
Descripción
Inclusion Criteria:
- Participants will be 50 to 75 years old.
- Hearing loss will be limited to 40 dB HL from 250 Hz through 1000 Hz, and to 60 dB HL through 4000 Hz.
- Hearing loss must be greater than 25 dB at two or more frequencies from 250 to 4000 Hz.
Exclusion Criteria:
- None of the participants will be current or past hearing aid users; all will be free of ear disease.
- Participants with conductive hearing losses, defined as air-bone gap greater than 15 dB, will be excluded.
- The audiometric battery with acoustic reflex thresholds and decay measurements will be used to exclude anyone with evidence of a central disorder or a pathology other than a sensorineural loss. Those potential participants will be referred to a medical professional.
Plan de estudios
¿Cómo está diseñado el estudio?
Detalles de diseño
- Propósito principal: Tratamiento
- Asignación: No aleatorizado
- Modelo Intervencionista: Asignación paralela
- Enmascaramiento: Ninguno (etiqueta abierta)
Armas e Intervenciones
Grupo de participantes/brazo |
Intervención / Tratamiento |
---|---|
Comparador activo: Mild Hearing Loss
Audiological Evaluation will show average hearing threshold at 500, 1000, 2000, and 4000 Hz of 20-39 decibels hearing level (dBHL)
|
Tests of hearing, cognition, and speech perception
|
Comparador activo: Moderate Hearing Loss
Audiological Evaluation will show average hearing threshold at 500, 1000, 2000, and 4000 Hz of 40-49 decibels hearing level (dBHL)
|
Tests of hearing, cognition, and speech perception
|
Comparador activo: Moderate-Severe Hearing Loss
Audiological Evaluation will show average hearing threshold at 500, 1000, 2000, and 4000 Hz greater than 50 decibels hearing level (dBHL)
|
Tests of hearing, cognition, and speech perception
|
¿Qué mide el estudio?
Medidas de resultado primarias
Medida de resultado |
Medida Descripción |
Periodo de tiempo |
---|---|---|
Ability to Understand Speech in Noise Background
Periodo de tiempo: one year
|
Measure speech perception for sentences in background noise
|
one year
|
Colaboradores e Investigadores
Patrocinador
Investigadores
- Investigador principal: Marjorie R. Leek, PhD, VA Loma Linda Healthcare System, Loma Linda, CA
Publicaciones y enlaces útiles
Fechas de registro del estudio
Fechas importantes del estudio
Inicio del estudio
Finalización primaria (Actual)
Finalización del estudio (Actual)
Fechas de registro del estudio
Enviado por primera vez
Primero enviado que cumplió con los criterios de control de calidad
Publicado por primera vez (Estimar)
Actualizaciones de registros de estudio
Última actualización publicada (Estimar)
Última actualización enviada que cumplió con los criterios de control de calidad
Última verificación
Más información
Términos relacionados con este estudio
Palabras clave
Términos MeSH relevantes adicionales
Otros números de identificación del estudio
- C4338-R
Información sobre medicamentos y dispositivos, documentos del estudio
Estudia un producto farmacéutico regulado por la FDA de EE. UU.
Estudia un producto de dispositivo regulado por la FDA de EE. UU.
producto fabricado y exportado desde los EE. UU.
Esta información se obtuvo directamente del sitio web clinicaltrials.gov sin cambios. Si tiene alguna solicitud para cambiar, eliminar o actualizar los detalles de su estudio, comuníquese con register@clinicaltrials.gov. Tan pronto como se implemente un cambio en clinicaltrials.gov, también se actualizará automáticamente en nuestro sitio web. .
Ensayos clínicos sobre Audiological Evaluation
-
University Hospital, Clermont-FerrandTerminado