- ICH GCP
- Registro degli studi clinici negli Stati Uniti
- Sperimentazione clinica NCT00371839
Clinical Applications for Time-Compressed Speech Tests
The purpose of this study is to determine the effects of age-related cognitive changes on hearing aid benefit based on hearing aid compression time constants.
The hypothesis is that people with poor working memory skills will benefit from slow time constants in hearing aid compression while those with good working memory skills will be able to benefit from more sophisticated compression algorithms with rapid time constants.
Panoramica dello studio
Stato
Condizioni
Intervento / Trattamento
Descrizione dettagliata
Recent research has shown the relevance of cognitive function in hearing aid evaluation and the sensitivity of the aging auditory system to temporal distortions. The proposed investigation will examine the interaction of working memory and hearing aid compression method on speech recognition in background competition for older listeners. This interaction will be investigated for the following three forms of background competition:
- Competition from continuous speech-shaped noise.
- Competition from speech-modulated noise.
- Competition from a single interfering talker.
The goals of the study will be accomplished in two phases. In the first phase, 160 adults aged 50 through 75 years will be evaluated on a battery of tests to determine their cognitive capacity, time-compressed speech scores and their candidacy for inclusion in the second phase of the study. At the conclusion of this phase of testing, the participants will be divided into three groups:
- subjects with TCS test scores in the highest quartile (the HIGH group)
- subjects with TCS test scores in the lowest quartile (the LOW group)
- the remaining listeners
The second phase of the experiment will include listeners from the HIGH and LOW groups only. These subjects will be evaluated with respect to their speech recognition ability for three types of interference (steady-state noise, speech-modulated noise, single interfering talker). The HINT test (Nilsson, Soli, & Sumida, 1995; Nilsson et al., 1994) will be used to obtain the signal-to-noise ratio (SNR) at 50% recognition for the three masking conditions for each of three types of amplification:
- one- channel linear amplification (LINEAR) with frequency shaping
- two-channel wide dynamic range compression with fast time constants (FAST)
- two-channel wide dynamic range compression with slow time constants (SLOW) Listener groups will be compared across hearing aid conditions and across background interference conditions.
Tipo di studio
Iscrizione (Effettivo)
Fase
- Non applicabile
Criteri di partecipazione
Criteri di ammissibilità
Età idonea allo studio
Accetta volontari sani
Sessi ammissibili allo studio
Descrizione
Inclusion Criteria:
- Participants will be 50 to 75 years old.
- Hearing loss will be limited to 40 dB HL from 250 Hz through 1000 Hz, and to 60 dB HL through 4000 Hz.
- Hearing loss must be greater than 25 dB at two or more frequencies from 250 to 4000 Hz.
Exclusion Criteria:
- None of the participants will be current or past hearing aid users; all will be free of ear disease.
- Participants with conductive hearing losses, defined as air-bone gap greater than 15 dB, will be excluded.
- The audiometric battery with acoustic reflex thresholds and decay measurements will be used to exclude anyone with evidence of a central disorder or a pathology other than a sensorineural loss. Those potential participants will be referred to a medical professional.
Piano di studio
Come è strutturato lo studio?
Dettagli di progettazione
- Scopo principale: Trattamento
- Assegnazione: Non randomizzato
- Modello interventistico: Assegnazione parallela
- Mascheramento: Nessuno (etichetta aperta)
Armi e interventi
Gruppo di partecipanti / Arm |
Intervento / Trattamento |
|---|---|
|
Comparatore attivo: Mild Hearing Loss
Audiological Evaluation will show average hearing threshold at 500, 1000, 2000, and 4000 Hz of 20-39 decibels hearing level (dBHL)
|
Tests of hearing, cognition, and speech perception
|
|
Comparatore attivo: Moderate Hearing Loss
Audiological Evaluation will show average hearing threshold at 500, 1000, 2000, and 4000 Hz of 40-49 decibels hearing level (dBHL)
|
Tests of hearing, cognition, and speech perception
|
|
Comparatore attivo: Moderate-Severe Hearing Loss
Audiological Evaluation will show average hearing threshold at 500, 1000, 2000, and 4000 Hz greater than 50 decibels hearing level (dBHL)
|
Tests of hearing, cognition, and speech perception
|
Cosa sta misurando lo studio?
Misure di risultato primarie
Misura del risultato |
Misura Descrizione |
Lasso di tempo |
|---|---|---|
|
Ability to Understand Speech in Noise Background
Lasso di tempo: one year
|
Measure speech perception for sentences in background noise
|
one year
|
Collaboratori e investigatori
Investigatori
- Investigatore principale: Marjorie R. Leek, PhD, VA Loma Linda Healthcare System, Loma Linda, CA
Pubblicazioni e link utili
Collegamenti utili
Studiare le date dei record
Studia le date principali
Inizio studio
Completamento primario (Effettivo)
Completamento dello studio (Effettivo)
Date di iscrizione allo studio
Primo inviato
Primo inviato che soddisfa i criteri di controllo qualità
Primo Inserito (Stima)
Aggiornamenti dei record di studio
Ultimo aggiornamento pubblicato (Stima)
Ultimo aggiornamento inviato che soddisfa i criteri QC
Ultimo verificato
Maggiori informazioni
Termini relativi a questo studio
Termini MeSH pertinenti aggiuntivi
Altri numeri di identificazione dello studio
- C4338-R
Informazioni su farmaci e dispositivi, documenti di studio
Studia un prodotto farmaceutico regolamentato dalla FDA degli Stati Uniti
Studia un dispositivo regolamentato dalla FDA degli Stati Uniti
prodotto fabbricato ed esportato dagli Stati Uniti
Queste informazioni sono state recuperate direttamente dal sito web clinicaltrials.gov senza alcuna modifica. In caso di richieste di modifica, rimozione o aggiornamento dei dettagli dello studio, contattare register@clinicaltrials.gov. Non appena verrà implementata una modifica su clinicaltrials.gov, questa verrà aggiornata automaticamente anche sul nostro sito web .