Ta strona została przetłumaczona automatycznie i dokładność tłumaczenia nie jest gwarantowana. Proszę odnieść się do angielska wersja za tekst źródłowy.

A Registry to Evaluate the Direct Flow Medical Transcatheter Aortic Valve System (DISCOVER)

23 lutego 2016 zaktualizowane przez: Direct Flow Medical, Inc.

A Registry to Evaluate the Direct Flow Medical Transcatheter Aortic Valve System for the Treatment of Patients With Severe Aortic Stenosis

The purpose of this postmarket Registry is to assess the standard of care and clinical outcomes of the Direct Flow Medical Transcatheter Aortic Valve System used in clinical routine according to the approved commercial indications. Procedures and assessments required by this registry are generally considered standard of care for Transcatheter Aortic Valve Replacement patients.

Evaluation criteria will be the incidence of mortality/morbidity and adverse events clinical performance, and hemodynamic performance of the DEVICE via ultrasound (echo) and angiographic imaging.

Przegląd badań

Status

Nieznany

Szczegółowy opis

The patient population will include patients who are candidates for transcatheter aortic valve replacement (TAVR). According to routine practice, the heart team (interventional cardiologist and cardiothoracic surgeon) makes a choice to use the Direct Flow Medical Aortic Valve System, compared to other available TAVR prostheses, on the basis of clinical and surgical considerations. Therefore, the valve is implanted when the heart team decides that this product is best suited to the specific patient.

In order to be enrolled in this Registry, the patient must be a candidate for the implantation of the Direct Flow Medical Transcatheter Aortic Valve System, based on the commercial indications as stated in the Instructions for Use.

Therefore, candidates for this study must meet the following criteria (Indications for Use):

  1. Age > 70 years old
  2. Severe aortic valve stenosis determined by echocardiogram and Doppler:

    • mean gradient >40 mmHg or peak jet velocity >4.0 m/s AND
    • aortic valve area ≤0.8 cm2 or aortic valve area index ≤0.5 cm2/m2
  3. Symptomatic aortic valve stenosis (angina, congestive heart failure, NYHA Functional Class ≥ II, or syncope).
  4. Patient is an extreme risk candidate for open surgical aortic valve repair such that the site Investigators (interventional cardiologist and cardiothoracic surgeon) agree that medical factors preclude operation, based on the conclusion that the probability of death or serious morbidity exceeds the probability of meaningful improvement due to the patient's co-morbidities (such as, but not limited to, severe COPD, porcelain aorta, previous thorax irradiation) or logistic EuroSCORE ≥ 20.

All the Registry clinical evaluations and tests performed are generally considered standard of care for TAVR patients. When these recommendations conflict with the standard of care at the Registry site, the standard of care should prevail. In addition to the standard of care, the Sponsor recommends one brief additional evaluation (the EQ-5D quality of life measure) be conducted. Failure to perform this evaluation shall not be considered a protocol deviation.

Baseline Clinical Evaluation

  • Medical History and Physical Exam
  • 12 lead ECG and Arrhythmia Assessment
  • Logistic EuroSCORE/STS Score
  • New York Heart Association (NYHA) functional status
  • Modified Rankin Score Assessment (mRS)
  • Current Cardiac Medications Baseline Imaging Studies
  • Transthoracic Echo (TTE)
  • CT Scan (ECG triggered, contrast enhanced)
  • Aorto-Iliac Angiogram:

    1. Peripheral Evaluation
    2. Coronary Evaluation

All patients will have clinical follow-up at hospital discharge, 30 days, 12 months and annually to 3 years and undergo the following evaluations:

  • Physical Exam
  • 12 lead ECG and Arrhythmia Assessment
  • New York Heart Association (NYHA) functional status
  • Modified Rankin Score Assessment (mRS) if symptomatic for stroke
  • Current Cardiac Medications
  • Transthoracic echo (TTE) Patients in whom the heart team has planned to use the Direct Flow Medical Transcatheter Aortic Valve System valve, are informed of the DISCOVER Registry and their consent to participate is required. This study intends to monitor the clinical condition of the patient for a period of 3 years after the operation. By agreeing to participate, the patient agrees to undergo clinical assessments and specific tests at certain intervals (prior to the procedure; during the implantation; at hospital discharge, at 30 days after the procedure, and at 1 year, 2 and 3 years later); the patient also agrees to the collection of these daThe purpose of this Registry is to monitor outcomes data for the Direct Flow Medical Transcatheter Aortic Valve System in the Post Market phase. The primary outcome of interest is freedom from all-cause mortality at 30 days. The results from the pivotal CE mark study (IP 010) yielded a 30 day freedom from all-cause mortality rate of 97%. Should the "true" rate be 97%, then N=250 patients would provide an estimate of the rate with a margin of error of 2%, with 95% confidence.

Typ studiów

Obserwacyjny

Zapisy (Oczekiwany)

1000

Kontakty i lokalizacje

Ta sekcja zawiera dane kontaktowe osób prowadzących badanie oraz informacje o tym, gdzie badanie jest przeprowadzane.

Lokalizacje studiów

      • Essen, Niemcy, 45138
        • Rekrutacyjny
        • Elisabeth Krankenhaus
        • Kontakt:
        • Kontakt:
        • Główny śledczy:
          • Christopher Naber, MD
      • Milan, Włochy, 20162
        • Rekrutacyjny
        • Ospedale Niguarda Ca' Granda
        • Główny śledczy:
          • Federico DeMarco, MD
        • Kontakt:

Kryteria uczestnictwa

Badacze szukają osób, które pasują do określonego opisu, zwanego kryteriami kwalifikacyjnymi. Niektóre przykłady tych kryteriów to ogólny stan zdrowia danej osoby lub wcześniejsze leczenie.

Kryteria kwalifikacji

Wiek uprawniający do nauki

71 lat i starsze (Starszy dorosły)

Akceptuje zdrowych ochotników

Nie

Płeć kwalifikująca się do nauki

Wszystko

Metoda próbkowania

Próbka bez prawdopodobieństwa

Badana populacja

The Direct Flow Medical Transcatheter Aortic Valve System is intended for use in patients with severe aortic valve stenosis who require replacement of their native aortic valve but are extreme risk candidates for open surgical replacement. This is in accordance with the product Intended Use in the commercial Instructions for Use.

Opis

Candidates for this study must meet all of the Indications criteria and none of the Contraindications.

Inclusion Criteria (Indications):

  1. Age > 70 years old
  2. Severe aortic valve stenosis determined by echocardiogram and Doppler:

    • mean gradient >40 mmHg or peak jet velocity >4.0 m/s
    • aortic valve area ≤0.8 cm2 or aortic valve area index ≤0.5 cm2/m2
  3. Symptomatic aortic valve stenosis (angina, congestive heart failure, NYHA Functional Class ≥ II, or syncope).
  4. Patient is an extreme risk candidate for open surgical aortic valve repair such that the site Investigators (interventional cardiologist and cardiothoracic surgeon) agree that medical factors preclude operation, based on the conclusion that the probability of death or serious morbidity exceeds the probability of meaningful improvement due to the patient's co-morbidities (such as, but not limited to, severe COPD, porcelain aorta, previous thorax irradiation) or logistic EuroSCORE ≥ 20.

Exclusion Criteria (Contraindications):

The Direct Flow Medical device is contraindicated for post implant balloon valvuloplasty.

Plan studiów

Ta sekcja zawiera szczegółowe informacje na temat planu badania, w tym sposób zaprojektowania badania i jego pomiary.

Jak projektuje się badanie?

Szczegóły projektu

Kohorty i interwencje

Grupa / Kohorta
Interwencja / Leczenie
aortic valve disease
aortic valve replacement
Transthoracic Echo (TTE),CT Scan (ECG triggered, contrast enhanced),Aorto-Iliac Angiogram,Peripheral Evaluation,Coronary Evaluation,12 lead ECG,Arrhythmia Assessment, New York Heart Association (NYHA) functional status, Modified Rankin Score Assessment (mRS) if symptomatic for stroke, Current Cardiac Medications, Transthoracic echo (TTE)
Inne nazwy:
  • Direct Flow Medical Percutaneous Aortic Valve 18F System
  • Discover
  • Transcatheter

Co mierzy badanie?

Podstawowe miary wyniku

Miara wyniku
Ramy czasowe
Freedom from all-cause mortality at 30 days
Ramy czasowe: 30 days
30 days

Miary wyników drugorzędnych

Miara wyniku
Opis środka
Ramy czasowe
Device Success (VARC defined)
Ramy czasowe: 30 days
  • Absence of procedural mortality AND
  • Correct positioning of a single prosthetic heart valve into the proper anatomic location AND
  • Intended performance of the prosthetic heart valve (no prosthesis-patient mismatch and mean aortic valve gradient <20mmHg or peak velocity <3m/s, AND no moderate or severe prosthetic valve regurgitation)
30 days
Early Safety
Ramy czasowe: 30 days
  • All-cause mortality
  • All stroke (disabling and non-disabling)
  • Life-threatening bleeding
  • Acute Kidney Injury - Stage 2 or 3 (including renal replacement therapy)
  • Coronary artery obstruction requiring intervention
  • Major vascular complications
  • Valve-related dysfunction requiring repeat procedure (BAV, TAVR, or SAVR)
30 days
Clinical efficacy
Ramy czasowe: 30 days through 5 years
  • All-cause mortality
  • All stroke (disabling and non-disabling)
  • Hospitalization for valve-related symptoms or worsening congestive heart failure
30 days through 5 years
Clinical efficacy
Ramy czasowe: 30 days through 5 years
• NYHA Class III or IV
30 days through 5 years
Clinical efficacy
Ramy czasowe: 30 days through 5 years
• Prosthetic heart valve dysfunction (mean aortic valve gradient ≥20mm Hg, EOA ≤0.9-1.1cm2 [depending on body surface area] and/or DVI <0.35, AND/OR moderate or severe prosthetic valve regurgitation)
30 days through 5 years
Time-related Valve Safety
Ramy czasowe: 5 years

• Structural valve deterioration:

  • Valve-related dysfunction (mean aortic valve gradient (mean aortic valve gradient ≥20mmHg, EOA ≤0.9-1.1cm2 [depending on body surface area] and/or DVI <0.35, AND/OR moderate or severe prosthetic valve regurgitation)
  • Requiring repeat procedure (TAVR or SAVR)
5 years
Time-related Valve Safety
Ramy czasowe: 5 years
  • Prosthetic valve endocarditis
  • Prosthetic valve thrombosis
  • Thromboembolic events (e.g., stroke)
  • VARC bleeding, unless clearly unrelated to valve therapy (e.g., trauma)
5 years

Współpracownicy i badacze

Tutaj znajdziesz osoby i organizacje zaangażowane w to badanie.

Śledczy

  • Główny śledczy: Christopher Naber, MD, Elisabeth Krankenhaus Essen GmbH

Publikacje i pomocne linki

Osoba odpowiedzialna za wprowadzenie informacji o badaniu dobrowolnie udostępnia te publikacje. Mogą one dotyczyć wszystkiego, co jest związane z badaniem.

Przydatne linki

Daty zapisu na studia

Daty te śledzą postęp w przesyłaniu rekordów badań i podsumowań wyników do ClinicalTrials.gov. Zapisy badań i zgłoszone wyniki są przeglądane przez National Library of Medicine (NLM), aby upewnić się, że spełniają określone standardy kontroli jakości, zanim zostaną opublikowane na publicznej stronie internetowej.

Główne daty studiów

Rozpoczęcie studiów

1 marca 2013

Zakończenie podstawowe (Oczekiwany)

1 grudnia 2016

Ukończenie studiów (Oczekiwany)

1 grudnia 2019

Daty rejestracji na studia

Pierwszy przesłany

30 kwietnia 2013

Pierwszy przesłany, który spełnia kryteria kontroli jakości

1 maja 2013

Pierwszy wysłany (Oszacować)

3 maja 2013

Aktualizacje rekordów badań

Ostatnia wysłana aktualizacja (Oszacować)

24 lutego 2016

Ostatnia przesłana aktualizacja, która spełniała kryteria kontroli jakości

23 lutego 2016

Ostatnia weryfikacja

1 lutego 2016

Więcej informacji

Terminy związane z tym badaniem

Plan dla danych uczestnika indywidualnego (IPD)

Planujesz udostępniać dane poszczególnych uczestników (IPD)?

NIEZDECYDOWANY

Te informacje zostały pobrane bezpośrednio ze strony internetowej clinicaltrials.gov bez żadnych zmian. Jeśli chcesz zmienić, usunąć lub zaktualizować dane swojego badania, skontaktuj się z register@clinicaltrials.gov. Gdy tylko zmiana zostanie wprowadzona na stronie clinicaltrials.gov, zostanie ona automatycznie zaktualizowana również na naszej stronie internetowej .

Badania kliniczne na Aortic Valve Replacement

Subskrybuj