- ICH GCP
- US-Register für klinische Studien
- Klinische Studie NCT01845285
A Registry to Evaluate the Direct Flow Medical Transcatheter Aortic Valve System (DISCOVER)
A Registry to Evaluate the Direct Flow Medical Transcatheter Aortic Valve System for the Treatment of Patients With Severe Aortic Stenosis
The purpose of this postmarket Registry is to assess the standard of care and clinical outcomes of the Direct Flow Medical Transcatheter Aortic Valve System used in clinical routine according to the approved commercial indications. Procedures and assessments required by this registry are generally considered standard of care for Transcatheter Aortic Valve Replacement patients.
Evaluation criteria will be the incidence of mortality/morbidity and adverse events clinical performance, and hemodynamic performance of the DEVICE via ultrasound (echo) and angiographic imaging.
Studienübersicht
Status
Bedingungen
Intervention / Behandlung
Detaillierte Beschreibung
The patient population will include patients who are candidates for transcatheter aortic valve replacement (TAVR). According to routine practice, the heart team (interventional cardiologist and cardiothoracic surgeon) makes a choice to use the Direct Flow Medical Aortic Valve System, compared to other available TAVR prostheses, on the basis of clinical and surgical considerations. Therefore, the valve is implanted when the heart team decides that this product is best suited to the specific patient.
In order to be enrolled in this Registry, the patient must be a candidate for the implantation of the Direct Flow Medical Transcatheter Aortic Valve System, based on the commercial indications as stated in the Instructions for Use.
Therefore, candidates for this study must meet the following criteria (Indications for Use):
- Age > 70 years old
Severe aortic valve stenosis determined by echocardiogram and Doppler:
- mean gradient >40 mmHg or peak jet velocity >4.0 m/s AND
- aortic valve area ≤0.8 cm2 or aortic valve area index ≤0.5 cm2/m2
- Symptomatic aortic valve stenosis (angina, congestive heart failure, NYHA Functional Class ≥ II, or syncope).
- Patient is an extreme risk candidate for open surgical aortic valve repair such that the site Investigators (interventional cardiologist and cardiothoracic surgeon) agree that medical factors preclude operation, based on the conclusion that the probability of death or serious morbidity exceeds the probability of meaningful improvement due to the patient's co-morbidities (such as, but not limited to, severe COPD, porcelain aorta, previous thorax irradiation) or logistic EuroSCORE ≥ 20.
All the Registry clinical evaluations and tests performed are generally considered standard of care for TAVR patients. When these recommendations conflict with the standard of care at the Registry site, the standard of care should prevail. In addition to the standard of care, the Sponsor recommends one brief additional evaluation (the EQ-5D quality of life measure) be conducted. Failure to perform this evaluation shall not be considered a protocol deviation.
Baseline Clinical Evaluation
- Medical History and Physical Exam
- 12 lead ECG and Arrhythmia Assessment
- Logistic EuroSCORE/STS Score
- New York Heart Association (NYHA) functional status
- Modified Rankin Score Assessment (mRS)
- Current Cardiac Medications Baseline Imaging Studies
- Transthoracic Echo (TTE)
- CT Scan (ECG triggered, contrast enhanced)
Aorto-Iliac Angiogram:
- Peripheral Evaluation
- Coronary Evaluation
All patients will have clinical follow-up at hospital discharge, 30 days, 12 months and annually to 3 years and undergo the following evaluations:
- Physical Exam
- 12 lead ECG and Arrhythmia Assessment
- New York Heart Association (NYHA) functional status
- Modified Rankin Score Assessment (mRS) if symptomatic for stroke
- Current Cardiac Medications
- Transthoracic echo (TTE) Patients in whom the heart team has planned to use the Direct Flow Medical Transcatheter Aortic Valve System valve, are informed of the DISCOVER Registry and their consent to participate is required. This study intends to monitor the clinical condition of the patient for a period of 3 years after the operation. By agreeing to participate, the patient agrees to undergo clinical assessments and specific tests at certain intervals (prior to the procedure; during the implantation; at hospital discharge, at 30 days after the procedure, and at 1 year, 2 and 3 years later); the patient also agrees to the collection of these daThe purpose of this Registry is to monitor outcomes data for the Direct Flow Medical Transcatheter Aortic Valve System in the Post Market phase. The primary outcome of interest is freedom from all-cause mortality at 30 days. The results from the pivotal CE mark study (IP 010) yielded a 30 day freedom from all-cause mortality rate of 97%. Should the "true" rate be 97%, then N=250 patients would provide an estimate of the rate with a margin of error of 2%, with 95% confidence.
Studientyp
Einschreibung (Voraussichtlich)
Kontakte und Standorte
Studienorte
-
-
-
Essen, Deutschland, 45138
- Rekrutierung
- Elisabeth Krankenhaus
-
Kontakt:
- Christopher Naber, MD
- Telefonnummer: +492018970
- E-Mail: c.naber@contilia.de
-
Kontakt:
- Elisabeth Blank, RN
- Telefonnummer: +49 201 8973218
- E-Mail: e.blank@contilia.de
-
Hauptermittler:
- Christopher Naber, MD
-
-
-
-
-
Milan, Italien, 20162
- Rekrutierung
- Ospedale Niguarda Ca' Granda
-
Hauptermittler:
- Federico DeMarco, MD
-
Kontakt:
- Federico DeMarco, MD
- Telefonnummer: +390264442585
- E-Mail: federico.demarco@gmail.com
-
-
Teilnahmekriterien
Zulassungskriterien
Studienberechtigtes Alter
Akzeptiert gesunde Freiwillige
Studienberechtigte Geschlechter
Probenahmeverfahren
Studienpopulation
Beschreibung
Candidates for this study must meet all of the Indications criteria and none of the Contraindications.
Inclusion Criteria (Indications):
- Age > 70 years old
Severe aortic valve stenosis determined by echocardiogram and Doppler:
- mean gradient >40 mmHg or peak jet velocity >4.0 m/s
- aortic valve area ≤0.8 cm2 or aortic valve area index ≤0.5 cm2/m2
- Symptomatic aortic valve stenosis (angina, congestive heart failure, NYHA Functional Class ≥ II, or syncope).
- Patient is an extreme risk candidate for open surgical aortic valve repair such that the site Investigators (interventional cardiologist and cardiothoracic surgeon) agree that medical factors preclude operation, based on the conclusion that the probability of death or serious morbidity exceeds the probability of meaningful improvement due to the patient's co-morbidities (such as, but not limited to, severe COPD, porcelain aorta, previous thorax irradiation) or logistic EuroSCORE ≥ 20.
Exclusion Criteria (Contraindications):
The Direct Flow Medical device is contraindicated for post implant balloon valvuloplasty.
Studienplan
Wie ist die Studie aufgebaut?
Designdetails
Kohorten und Interventionen
Gruppe / Kohorte |
Intervention / Behandlung |
|---|---|
|
aortic valve disease
aortic valve replacement
|
Transthoracic Echo (TTE),CT Scan (ECG triggered, contrast enhanced),Aorto-Iliac Angiogram,Peripheral Evaluation,Coronary Evaluation,12 lead ECG,Arrhythmia Assessment, New York Heart Association (NYHA) functional status, Modified Rankin Score Assessment (mRS) if symptomatic for stroke, Current Cardiac Medications, Transthoracic echo (TTE)
Andere Namen:
|
Was misst die Studie?
Primäre Ergebnismessungen
Ergebnis Maßnahme |
Zeitfenster |
|---|---|
|
Freedom from all-cause mortality at 30 days
Zeitfenster: 30 days
|
30 days
|
Sekundäre Ergebnismessungen
Ergebnis Maßnahme |
Maßnahmenbeschreibung |
Zeitfenster |
|---|---|---|
|
Device Success (VARC defined)
Zeitfenster: 30 days
|
|
30 days
|
|
Early Safety
Zeitfenster: 30 days
|
|
30 days
|
|
Clinical efficacy
Zeitfenster: 30 days through 5 years
|
|
30 days through 5 years
|
|
Clinical efficacy
Zeitfenster: 30 days through 5 years
|
• NYHA Class III or IV
|
30 days through 5 years
|
|
Clinical efficacy
Zeitfenster: 30 days through 5 years
|
• Prosthetic heart valve dysfunction (mean aortic valve gradient ≥20mm Hg, EOA ≤0.9-1.1cm2
[depending on body surface area] and/or DVI <0.35, AND/OR moderate or severe prosthetic valve regurgitation)
|
30 days through 5 years
|
|
Time-related Valve Safety
Zeitfenster: 5 years
|
• Structural valve deterioration:
|
5 years
|
|
Time-related Valve Safety
Zeitfenster: 5 years
|
|
5 years
|
Mitarbeiter und Ermittler
Sponsor
Ermittler
- Hauptermittler: Christopher Naber, MD, Elisabeth Krankenhaus Essen GmbH
Publikationen und hilfreiche Links
Nützliche Links
Studienaufzeichnungsdaten
Haupttermine studieren
Studienbeginn
Primärer Abschluss (Voraussichtlich)
Studienabschluss (Voraussichtlich)
Studienanmeldedaten
Zuerst eingereicht
Zuerst eingereicht, das die QC-Kriterien erfüllt hat
Zuerst gepostet (Schätzen)
Studienaufzeichnungsaktualisierungen
Letztes Update gepostet (Schätzen)
Letztes eingereichtes Update, das die QC-Kriterien erfüllt
Zuletzt verifiziert
Mehr Informationen
Begriffe im Zusammenhang mit dieser Studie
Schlüsselwörter
Zusätzliche relevante MeSH-Bedingungen
Andere Studien-ID-Nummern
- RP 001
Plan für individuelle Teilnehmerdaten (IPD)
Planen Sie, individuelle Teilnehmerdaten (IPD) zu teilen?
Diese Informationen wurden ohne Änderungen direkt von der Website clinicaltrials.gov abgerufen. Wenn Sie Ihre Studiendaten ändern, entfernen oder aktualisieren möchten, wenden Sie sich bitte an register@clinicaltrials.gov. Sobald eine Änderung auf clinicaltrials.gov implementiert wird, wird diese automatisch auch auf unserer Website aktualisiert .
Klinische Studien zur Aortenklappenstenose
-
University of ZurichAktiv, nicht rekrutierendBecken- und Para-Aortic-LymphknotenmetastasenSchweiz
-
Samsun UniversityAktiv, nicht rekrutierendKoronararterien-Bypass-Operation (CABG) | Aufsteigendes Aortenaneurysma | Aortic Adventitial Pathology | Borderline AortendilatationTruthahn
-
Qun ZhaoFirst Hospital of Shijiazhuang City; Baoding First Central Hospital; Hengshui...Anmeldung auf EinladungMagenkrebs | Lymphatische Metastasierung | Künstliche Intelligenz | Radiomics | Para-Aortic-Lymphknotenmetastasierung | Präoperative BildgebungsbewertungChina
Klinische Studien zur Aortic Valve Replacement
-
Smith & Nephew Orthopaedics AGAbgeschlossenAvaskuläre Nekrose | Primäre Arthrose | Sekundäre Arthrose | Primärer totaler Hüftersatz (THR)Vereinigtes Königreich
-
Ranier Technology LimitedAbgeschlossenChronische Rückenschmerzen | Lumbale degenerative BandscheibenerkrankungBelgien, Niederlande, Vereinigtes Königreich, Deutschland
-
magAssist, Inc.Aktiv, nicht rekrutierend
-
Sutra Medical, Inc.Rekrutierung
-
University Hospital, Strasbourg, FranceNoch keine RekrutierungEndometriumkarzinom | Lymphadenektomie | Gen, p53 | Sentinel-Lymphknoten-Biopsie (SLNB)
-
Symetis SAAbgeschlossenAortenstenoseDeutschland, Dänemark, Schweiz
-
Università degli Studi di SassariAbgeschlossen
-
Ataturk UniversityAbgeschlossenKoronare Herzkrankheit | Akuter Myokardinfarkt | Troponin | Koronare Bypass-Transplantatstenose eines autologen Gefäßes | IABP – Störung der intraaortalen BallonpumpeTruthahn
-
Spinal Stabilization TechnologiesBeendetChronische Rückenschmerzen | Degenerative BandscheibenerkrankungenParaguay
-
IsalaZorgvernieuwingAbgeschlossen