Denne side blev automatisk oversat, og nøjagtigheden af ​​oversættelsen er ikke garanteret. Der henvises til engelsk version for en kildetekst.

A Registry to Evaluate the Direct Flow Medical Transcatheter Aortic Valve System (DISCOVER)

23. februar 2016 opdateret af: Direct Flow Medical, Inc.

A Registry to Evaluate the Direct Flow Medical Transcatheter Aortic Valve System for the Treatment of Patients With Severe Aortic Stenosis

The purpose of this postmarket Registry is to assess the standard of care and clinical outcomes of the Direct Flow Medical Transcatheter Aortic Valve System used in clinical routine according to the approved commercial indications. Procedures and assessments required by this registry are generally considered standard of care for Transcatheter Aortic Valve Replacement patients.

Evaluation criteria will be the incidence of mortality/morbidity and adverse events clinical performance, and hemodynamic performance of the DEVICE via ultrasound (echo) and angiographic imaging.

Studieoversigt

Status

Ukendt

Betingelser

Intervention / Behandling

Detaljeret beskrivelse

The patient population will include patients who are candidates for transcatheter aortic valve replacement (TAVR). According to routine practice, the heart team (interventional cardiologist and cardiothoracic surgeon) makes a choice to use the Direct Flow Medical Aortic Valve System, compared to other available TAVR prostheses, on the basis of clinical and surgical considerations. Therefore, the valve is implanted when the heart team decides that this product is best suited to the specific patient.

In order to be enrolled in this Registry, the patient must be a candidate for the implantation of the Direct Flow Medical Transcatheter Aortic Valve System, based on the commercial indications as stated in the Instructions for Use.

Therefore, candidates for this study must meet the following criteria (Indications for Use):

  1. Age > 70 years old
  2. Severe aortic valve stenosis determined by echocardiogram and Doppler:

    • mean gradient >40 mmHg or peak jet velocity >4.0 m/s AND
    • aortic valve area ≤0.8 cm2 or aortic valve area index ≤0.5 cm2/m2
  3. Symptomatic aortic valve stenosis (angina, congestive heart failure, NYHA Functional Class ≥ II, or syncope).
  4. Patient is an extreme risk candidate for open surgical aortic valve repair such that the site Investigators (interventional cardiologist and cardiothoracic surgeon) agree that medical factors preclude operation, based on the conclusion that the probability of death or serious morbidity exceeds the probability of meaningful improvement due to the patient's co-morbidities (such as, but not limited to, severe COPD, porcelain aorta, previous thorax irradiation) or logistic EuroSCORE ≥ 20.

All the Registry clinical evaluations and tests performed are generally considered standard of care for TAVR patients. When these recommendations conflict with the standard of care at the Registry site, the standard of care should prevail. In addition to the standard of care, the Sponsor recommends one brief additional evaluation (the EQ-5D quality of life measure) be conducted. Failure to perform this evaluation shall not be considered a protocol deviation.

Baseline Clinical Evaluation

  • Medical History and Physical Exam
  • 12 lead ECG and Arrhythmia Assessment
  • Logistic EuroSCORE/STS Score
  • New York Heart Association (NYHA) functional status
  • Modified Rankin Score Assessment (mRS)
  • Current Cardiac Medications Baseline Imaging Studies
  • Transthoracic Echo (TTE)
  • CT Scan (ECG triggered, contrast enhanced)
  • Aorto-Iliac Angiogram:

    1. Peripheral Evaluation
    2. Coronary Evaluation

All patients will have clinical follow-up at hospital discharge, 30 days, 12 months and annually to 3 years and undergo the following evaluations:

  • Physical Exam
  • 12 lead ECG and Arrhythmia Assessment
  • New York Heart Association (NYHA) functional status
  • Modified Rankin Score Assessment (mRS) if symptomatic for stroke
  • Current Cardiac Medications
  • Transthoracic echo (TTE) Patients in whom the heart team has planned to use the Direct Flow Medical Transcatheter Aortic Valve System valve, are informed of the DISCOVER Registry and their consent to participate is required. This study intends to monitor the clinical condition of the patient for a period of 3 years after the operation. By agreeing to participate, the patient agrees to undergo clinical assessments and specific tests at certain intervals (prior to the procedure; during the implantation; at hospital discharge, at 30 days after the procedure, and at 1 year, 2 and 3 years later); the patient also agrees to the collection of these daThe purpose of this Registry is to monitor outcomes data for the Direct Flow Medical Transcatheter Aortic Valve System in the Post Market phase. The primary outcome of interest is freedom from all-cause mortality at 30 days. The results from the pivotal CE mark study (IP 010) yielded a 30 day freedom from all-cause mortality rate of 97%. Should the "true" rate be 97%, then N=250 patients would provide an estimate of the rate with a margin of error of 2%, with 95% confidence.

Undersøgelsestype

Observationel

Tilmelding (Forventet)

1000

Kontakter og lokationer

Dette afsnit indeholder kontaktoplysninger for dem, der udfører undersøgelsen, og oplysninger om, hvor denne undersøgelse udføres.

Studiesteder

      • Milan, Italien, 20162
        • Rekruttering
        • Ospedale Niguarda Ca' Granda
        • Ledende efterforsker:
          • Federico DeMarco, MD
        • Kontakt:
      • Essen, Tyskland, 45138
        • Rekruttering
        • Elisabeth Krankenhaus
        • Kontakt:
        • Kontakt:
        • Ledende efterforsker:
          • Christopher Naber, MD

Deltagelseskriterier

Forskere leder efter personer, der passer til en bestemt beskrivelse, kaldet berettigelseskriterier. Nogle eksempler på disse kriterier er en persons generelle helbredstilstand eller tidligere behandlinger.

Berettigelseskriterier

Aldre berettiget til at studere

71 år og ældre (Ældre voksen)

Tager imod sunde frivillige

Ingen

Køn, der er berettiget til at studere

Alle

Prøveudtagningsmetode

Ikke-sandsynlighedsprøve

Studiebefolkning

The Direct Flow Medical Transcatheter Aortic Valve System is intended for use in patients with severe aortic valve stenosis who require replacement of their native aortic valve but are extreme risk candidates for open surgical replacement. This is in accordance with the product Intended Use in the commercial Instructions for Use.

Beskrivelse

Candidates for this study must meet all of the Indications criteria and none of the Contraindications.

Inclusion Criteria (Indications):

  1. Age > 70 years old
  2. Severe aortic valve stenosis determined by echocardiogram and Doppler:

    • mean gradient >40 mmHg or peak jet velocity >4.0 m/s
    • aortic valve area ≤0.8 cm2 or aortic valve area index ≤0.5 cm2/m2
  3. Symptomatic aortic valve stenosis (angina, congestive heart failure, NYHA Functional Class ≥ II, or syncope).
  4. Patient is an extreme risk candidate for open surgical aortic valve repair such that the site Investigators (interventional cardiologist and cardiothoracic surgeon) agree that medical factors preclude operation, based on the conclusion that the probability of death or serious morbidity exceeds the probability of meaningful improvement due to the patient's co-morbidities (such as, but not limited to, severe COPD, porcelain aorta, previous thorax irradiation) or logistic EuroSCORE ≥ 20.

Exclusion Criteria (Contraindications):

The Direct Flow Medical device is contraindicated for post implant balloon valvuloplasty.

Studieplan

Dette afsnit indeholder detaljer om studieplanen, herunder hvordan undersøgelsen er designet, og hvad undersøgelsen måler.

Hvordan er undersøgelsen tilrettelagt?

Design detaljer

Kohorter og interventioner

Gruppe / kohorte
Intervention / Behandling
aortic valve disease
aortic valve replacement
Transthoracic Echo (TTE),CT Scan (ECG triggered, contrast enhanced),Aorto-Iliac Angiogram,Peripheral Evaluation,Coronary Evaluation,12 lead ECG,Arrhythmia Assessment, New York Heart Association (NYHA) functional status, Modified Rankin Score Assessment (mRS) if symptomatic for stroke, Current Cardiac Medications, Transthoracic echo (TTE)
Andre navne:
  • Direct Flow Medical Percutaneous Aortic Valve 18F System
  • Discover
  • Transcatheter

Hvad måler undersøgelsen?

Primære resultatmål

Resultatmål
Tidsramme
Freedom from all-cause mortality at 30 days
Tidsramme: 30 days
30 days

Sekundære resultatmål

Resultatmål
Foranstaltningsbeskrivelse
Tidsramme
Device Success (VARC defined)
Tidsramme: 30 days
  • Absence of procedural mortality AND
  • Correct positioning of a single prosthetic heart valve into the proper anatomic location AND
  • Intended performance of the prosthetic heart valve (no prosthesis-patient mismatch and mean aortic valve gradient <20mmHg or peak velocity <3m/s, AND no moderate or severe prosthetic valve regurgitation)
30 days
Early Safety
Tidsramme: 30 days
  • All-cause mortality
  • All stroke (disabling and non-disabling)
  • Life-threatening bleeding
  • Acute Kidney Injury - Stage 2 or 3 (including renal replacement therapy)
  • Coronary artery obstruction requiring intervention
  • Major vascular complications
  • Valve-related dysfunction requiring repeat procedure (BAV, TAVR, or SAVR)
30 days
Clinical efficacy
Tidsramme: 30 days through 5 years
  • All-cause mortality
  • All stroke (disabling and non-disabling)
  • Hospitalization for valve-related symptoms or worsening congestive heart failure
30 days through 5 years
Clinical efficacy
Tidsramme: 30 days through 5 years
• NYHA Class III or IV
30 days through 5 years
Clinical efficacy
Tidsramme: 30 days through 5 years
• Prosthetic heart valve dysfunction (mean aortic valve gradient ≥20mm Hg, EOA ≤0.9-1.1cm2 [depending on body surface area] and/or DVI <0.35, AND/OR moderate or severe prosthetic valve regurgitation)
30 days through 5 years
Time-related Valve Safety
Tidsramme: 5 years

• Structural valve deterioration:

  • Valve-related dysfunction (mean aortic valve gradient (mean aortic valve gradient ≥20mmHg, EOA ≤0.9-1.1cm2 [depending on body surface area] and/or DVI <0.35, AND/OR moderate or severe prosthetic valve regurgitation)
  • Requiring repeat procedure (TAVR or SAVR)
5 years
Time-related Valve Safety
Tidsramme: 5 years
  • Prosthetic valve endocarditis
  • Prosthetic valve thrombosis
  • Thromboembolic events (e.g., stroke)
  • VARC bleeding, unless clearly unrelated to valve therapy (e.g., trauma)
5 years

Samarbejdspartnere og efterforskere

Det er her, du vil finde personer og organisationer, der er involveret i denne undersøgelse.

Efterforskere

  • Ledende efterforsker: Christopher Naber, MD, Elisabeth Krankenhaus Essen GmbH

Publikationer og nyttige links

Den person, der er ansvarlig for at indtaste oplysninger om undersøgelsen, leverer frivilligt disse publikationer. Disse kan handle om alt relateret til undersøgelsen.

Hjælpsomme links

Datoer for undersøgelser

Disse datoer sporer fremskridtene for indsendelser af undersøgelsesrekord og resumeresultater til ClinicalTrials.gov. Studieregistreringer og rapporterede resultater gennemgås af National Library of Medicine (NLM) for at sikre, at de opfylder specifikke kvalitetskontrolstandarder, før de offentliggøres på den offentlige hjemmeside.

Studer store datoer

Studiestart

1. marts 2013

Primær færdiggørelse (Forventet)

1. december 2016

Studieafslutning (Forventet)

1. december 2019

Datoer for studieregistrering

Først indsendt

30. april 2013

Først indsendt, der opfyldte QC-kriterier

1. maj 2013

Først opslået (Skøn)

3. maj 2013

Opdateringer af undersøgelsesjournaler

Sidste opdatering sendt (Skøn)

24. februar 2016

Sidste opdatering indsendt, der opfyldte kvalitetskontrolkriterier

23. februar 2016

Sidst verificeret

1. februar 2016

Mere information

Begreber relateret til denne undersøgelse

Plan for individuelle deltagerdata (IPD)

Planlægger du at dele individuelle deltagerdata (IPD)?

UBESLUTET

Disse oplysninger blev hentet direkte fra webstedet clinicaltrials.gov uden ændringer. Hvis du har nogen anmodninger om at ændre, fjerne eller opdatere dine undersøgelsesoplysninger, bedes du kontakte register@clinicaltrials.gov. Så snart en ændring er implementeret på clinicaltrials.gov, vil denne også blive opdateret automatisk på vores hjemmeside .

Kliniske forsøg med Aortaklapstenose

Kliniske forsøg med Aortic Valve Replacement

Abonner