Poprawa ruchu dobrowolnego w szerokich populacjach pacjentów dzięki modułowym zasilanym ortezom

26 października 2026 zaktualizowane przez: Robert D Gregg, University of Michigan

The overall goal of this project is to develop modular, lower-limb, powered orthoses that fit to user-specific weakened joints and control force/torque in a manner that enhances voluntary motion in broad patient populations. This project aims to establish feasibility of assisting different populations with these modular powered orthoses. The investigators hypothesize that assisting lower-limb musculature with modular powered orthoses will improve 1) lifting/lowering posture in able-bodied subjects and 2) functional outcomes in elderly subjects.

Przegląd badań

Szczegółowy opis

The overall goal of this project is to develop modular, lower-limb, powered orthoses that fit to user-specific weakened joints and control force/torque in a manner that enhances voluntary motion in broad patient populations. Conventional orthoses tend to immobilize joints, and emerging powered orthoses constrain voluntary motion by using highly geared electric motors and/or control methods that force the user to follow a specific gait pattern. Consequently, these devices have not seen widespread success across populations with weakened voluntary control due to advanced age, musculoskeletal disorders, etc. These heterogeneous populations require partial, not full, assistance of user-specific muscle groups during daily activities. However, there is a fundamental gap in knowledge about how to design and control powered orthoses to assist the user without constraining their motion. The central hypothesis of this project is that high-torque, low-inertia motor systems controlled with energetic objectives will enable modular powered orthoses to partially assist the joints. High-torque electric motors combined with minimal transmissions can be freely rotated (i.e., backdriven) by human joints, allowing the use of an emerging torque control method called energy shaping to reduce the perceived weight/inertia of the body during any motion. By mounting these modular actuators to commercial orthoses, this technology will be easily prescribed/configured by clinicians. This project aims to establish feasibility of assisting different populations with modular powered orthoses. The investigators hypothesize that assisting lower-limb musculature with modular powered orthoses will improve 1) lifting/lowering posture in able-bodied subjects and 2) functional outcomes in elderly subjects.

Typ studiów

Interwencyjne

Zapisy (Rzeczywisty)

27

Faza

  • Nie dotyczy

Kontakty i lokalizacje

Ta sekcja zawiera dane kontaktowe osób prowadzących badanie oraz informacje o tym, gdzie badanie jest przeprowadzane.

Lokalizacje studiów

    • Michigan
      • Ann Arbor, Michigan, Stany Zjednoczone, 48109
        • Rehab Lab, University of Michigan

Kryteria uczestnictwa

Badacze szukają osób, które pasują do określonego opisu, zwanego kryteriami kwalifikacyjnymi. Niektóre przykłady tych kryteriów to ogólny stan zdrowia danej osoby lub wcześniejsze leczenie.

Kryteria kwalifikacji

Wiek uprawniający do nauki

18 lat do 85 lat (Dorosły, Starszy dorosły)

Akceptuje zdrowych ochotników

Tak

Płeć kwalifikująca się do nauki

Wszystko

Opis

Inclusion criteria for able-bodied, young participants will be:

  • Aged between 18 to 65 years
  • Weigh less than 250 lbs due to limitations in the design of the orthoses
  • Ability to lift and lower a 10 kg weight using the neutral-spine squat technique for 10 repetitions

Exclusion criteria for able-bodied, young adult participants will be:

  • Pregnant (self-report)
  • Any significant neuromuscular or musculoskeletal disorder that would interfere with the study
  • Prior history of chronic lower-back pain
  • Unable to walk for 20 minutes
  • History of any cardiovascular, vestibular, or visual diseases and/or impairments that may interfere with the study
  • Cognitive deficits that would impair their ability to give informed consent or impair their ability to follow simple instructions during the experiments. Cognitive deficits will be determined by a Mini-Mental State Examination (MMSE) score of <22.
  • Adults with a known allergy to medical grade tape

Inclusion criteria for elderly participants will be:

  • Aged between 65 to 85 years
  • Weigh less than 250 lbs due to limitations in the design of the orthoses
  • Ability to walk 6 minutes without assistance from a person (may use walking aid)

Exclusion criteria for elderly participants will be:

  • Pregnant (self-report)
  • Significant pain due to arthritis or other joint problems that would limit their ability to walk
  • Any recent lower-extremity fracture (within 3 months)
  • Significant neurological (e.g., stroke), orthopedic, or cardiovascular disorder that may affect the ability to walk
  • Advised by a physician not to walk or exercise
  • Uncontrolled hypertension or diabetes
  • Cognitive deficits or visual impairment that would impair their ability to give informed consent or impair their ability to follow simple instructions during the experiments. Cognitive deficits will be determined by a Mini-Mental State Examination (MMSE) score of <22.
  • Adults with a known allergy to medical grade tape

Plan studiów

Ta sekcja zawiera szczegółowe informacje na temat planu badania, w tym sposób zaprojektowania badania i jego pomiary.

Jak projektuje się badanie?

Szczegóły projektu

  • Główny cel: Inny
  • Przydział: Nie dotyczy
  • Model interwencyjny: Zadanie dla jednej grupy
  • Maskowanie: Brak (otwarta etykieta)

Broń i interwencje

Grupa uczestników / Arm
Interwencja / Leczenie
Eksperymentalny: Exoskeleton

Participants in this arm of the study will perform various tasks while wearing the modular powered orthosis

This study will investigate modular, lower-limb, powered orthoses that fit to user-specific weakened joints and control force/torque in a manner that enhances voluntary motion in broad patient populations. The central hypothesis is that high-torque, low-inertia motor systems controlled with energetic objectives will enable modular powered orthoses to partially assist the joints. High-torque electric motors combined with minimal transmissions can be freely rotated (i.e., backdriven) by human joints, allowing the use of an emerging torque control method called energy shaping to reduce the perceived weight/inertia of the body during any motion. By mounting these modular actuators to commercial orthoses, this technology will be easily prescribed/configured by clinicians.

Co mierzy badanie?

Podstawowe miary wyniku

Miara wyniku
Opis środka
Ramy czasowe
Muscle Effort (% MVC) With and Without Powered Orthosis - Able Bodied 1
Ramy czasowe: 1 day

For each orthosis module tested, electromyography (EMG) readings will be normalized per-muscle by the peak EMG observed during the no-orthosis condition, and then averaged over the cycle and across repetitions to obtain "normalized exertion" values. Data are presented as Muscle Effort (% Maximum Voluntary Contraction (MVC). Participants completed active movement trials and multi-terrain circuit loops under randomized conditions: 1) Baseline unassisted (No Exoskeleton) and 2) Assisted with active orthosis joint configurations running trajectory-free, task-invariant torque control via energy-shaping algorithms.

1 day
Quadriceps Muscle Effort (% MVC) With and Without Powered Orthosis - Able Bodied 2
Ramy czasowe: 1 day

We estimated quadriceps effort during six different lifting, lowering, and carrying (LLC) tasks (lifting-lowering (LL), level walking (LW), ramp ascent (RA), ramp descent (RD), stair ascent (SA), and stair descent (SD)) for the no-exo and exo conditions in a nonfatigued state. Muscle effort was calculated as the mean root mean square EMG, normalized to % maximum voluntary contraction (%MVC), over the gait/task cycle. Quadriceps effort was estimated by taking the weighted mean of the efforts of the vastus medialis oblique (VMO), vastus lateralis (VL), and rectus femoris (RF) based on their respective physiological cross-sectional areas.

1 day
Time to Complete 10 Reps of Lifting/Lowering
Ramy czasowe: 1 day, assessed per experimental condition (i.e. with orthosis and without orthosis)

Time to complete 10 reps of L&L will be measured post-fatigue in healthy subjects.

The reported outcome is measured in seconds to completion.

1 day, assessed per experimental condition (i.e. with orthosis and without orthosis)
Gait Speed
Ramy czasowe: 1 day, assessed per experimental condition (i.e. with orthosis and without orthosis)

Gait speed will be determined by the time to complete a 10-meter walk test. This will be the primary outcome measure for elderly subjects.

1 day, assessed per experimental condition (i.e. with orthosis and without orthosis)
Powered Orthosis Effect (Biological Torque)
Ramy czasowe: 1 day, assessed per experimental condition (i.e. with orthosis and without orthosis)

For each orthosis module tested, peak biological torque (estimated by inverse dynamics) will be averaged across repetitions. Performance will be assessed by the difference between the orthosis condition and no-orthosis condition, averaging across tasks. Participants walked on a Bertec instrumented treadmill with a level slope at 1.0 and 1.2 m/s, a 5◦-inclined and 5◦-declined slope at 1.0 m/s, and a 10◦-inclined and 10◦-declined slope at 0.8 m/s. Participants also performed stair ascent and descent on a 5-step staircase with 7 in (178 mm) step height, and STS transitions from a knee-height chair. All activities were performed both with the powered exoskeleton and without. Results are presented as mean torque (Newton-meters per kilogram (Nm/kg).

1 day, assessed per experimental condition (i.e. with orthosis and without orthosis)
Minimum Chair Height for Successful Sit-to-stand
Ramy czasowe: 1 day, assessed per experimental condition (i.e. with orthosis and without orthosis)

We will evaluate the minimum chair height from which elderly participants can successfully rise with and without the knee exoskeleton.

1 day, assessed per experimental condition (i.e. with orthosis and without orthosis)
Joint Power
Ramy czasowe: 1 day, assessed per experimental condition (i.e. with orthosis and without orthosis)

For elderly participants, we will evaluate the peak values of biological and total (exo+biological) joint power at the hip with and without the exoskeleton. Results presented as mean power in watts per kilogram (W/kg).

1 day, assessed per experimental condition (i.e. with orthosis and without orthosis)

Miary wyników drugorzędnych

Miara wyniku
Opis środka
Ramy czasowe
User Satisfaction
Ramy czasowe: 1 day, assessed per experimental condition (i.e. with orthosis and without orthosis), with orthosis reported

User satisfaction / perception of device effectiveness over an ambulation circuit (sit-to-stand, walk up and down a ramp, walk up and down a staircase) will be measured post-fatigue in healthy subjects using a modified Quebec User Evaluation of Satisfaction with Assistive Technology (QUEST 2.0) survey. The purpose of the scale is to evaluate user device satisfaction and consists of 12 items asking the user to rate their satisfaction on a scale of 1 to 5, where 1 = "not satisfied at all" and 5 = "very satisfied". The categories subjects were asked to rate were: Lifting/Lowering (LL), Ramp Ascent (RA), Stair Ascent (SA), Level walking (LW), Ramp Descent (RD), Stair Descent (SD)

1 day, assessed per experimental condition (i.e. with orthosis and without orthosis), with orthosis reported
Thorax Angle
Ramy czasowe: 1 day, assessed per experimental condition (i.e. with orthosis and without orthosis)

This is the global thorax angle (with respect to vertical) during a lifting/lowering cycle. This will be a secondary outcome measure for able-bodied subjects. Extracted at peak trunk lean (bottom of the squat) across 10 post-fatigue cycles. Measured in degrees of decrease in global thorax angle compared with the no-exoskeleton condition.

1 day, assessed per experimental condition (i.e. with orthosis and without orthosis)
Stair Ascent Gait Style
Ramy czasowe: 1 day, assessed per experimental condition (i.e. with orthosis and without orthosis)

Step-over-step gait style will be evaluated for the exo condition vs no exo condition for elderly participants.

1 day, assessed per experimental condition (i.e. with orthosis and without orthosis)

Współpracownicy i badacze

Tutaj znajdziesz osoby i organizacje zaangażowane w to badanie.

Publikacje i pomocne linki

Osoba odpowiedzialna za wprowadzenie informacji o badaniu dobrowolnie udostępnia te publikacje. Mogą one dotyczyć wszystkiego, co jest związane z badaniem.

Daty zapisu na studia

Daty te śledzą postęp w przesyłaniu rekordów badań i podsumowań wyników do ClinicalTrials.gov. Zapisy badań i zgłoszone wyniki są przeglądane przez National Library of Medicine (NLM), aby upewnić się, że spełniają określone standardy kontroli jakości, zanim zostaną opublikowane na publicznej stronie internetowej.

Główne daty studiów

Rozpoczęcie studiów (Rzeczywisty)

29 lipca 2022

Zakończenie podstawowe (Rzeczywisty)

6 sierpnia 2025

Ukończenie studiów (Rzeczywisty)

6 sierpnia 2025

Daty rejestracji na studia

Pierwszy przesłany

13 stycznia 2022

Pierwszy przesłany, który spełnia kryteria kontroli jakości

14 lutego 2022

Pierwszy wysłany (Rzeczywisty)

15 lutego 2022

Aktualizacje rekordów badań

Ostatnia wysłana aktualizacja (Rzeczywisty)

18 listopada 2026

Ostatnia przesłana aktualizacja, która spełniała kryteria kontroli jakości

26 października 2026

Ostatnia weryfikacja

1 października 2026

Więcej informacji

Terminy związane z tym badaniem

Plan dla danych uczestnika indywidualnego (IPD)

Planujesz udostępniać dane poszczególnych uczestników (IPD)?

NIEZDECYDOWANY

Informacje o lekach i urządzeniach, dokumenty badawcze

Bada produkt leczniczy regulowany przez amerykańską FDA

Nie

Bada produkt urządzenia regulowany przez amerykańską FDA

Tak

produkt wyprodukowany i wyeksportowany z USA

Nie

Te informacje zostały pobrane bezpośrednio ze strony internetowej clinicaltrials.gov bez żadnych zmian. Jeśli chcesz zmienić, usunąć lub zaktualizować dane swojego badania, skontaktuj się z register@clinicaltrials.gov. Gdy tylko zmiana zostanie wprowadzona na stronie clinicaltrials.gov, zostanie ona automatycznie zaktualizowana również na naszej stronie internetowej .