Esta página foi traduzida automaticamente e a precisão da tradução não é garantida. Por favor, consulte o versão em inglês para um texto fonte.

The Accuracy of Combined Parasternal Intercostal Muscle Thickening Fraction and Diaphragmatic Excursion in Predicting Failure of Libration From Mechanical Ventilation

17 de setembro de 2026 atualizado por: Gehad Ahmed Mohamed Amer, Cairo University

The Accuracy of Combined Parasternal Intercostal Muscle Thickening Fraction and Diaphragmatic Excursion in Predicting Failure of Libration From Mechanical Ventilation: A Prospective Cohort Study.

Approximately 20% of patients in the intensive care unit (ICU) requiring mechanical ventilation (MV) experience difficulty and prolonged weaning. Early spontaneous breathing trials (SBT) and timely extubation are essential to avoid complications such as diaphragmatic dysfunction, ventilator-associated pneumonia, and airway trauma.

Mechanical ventilation is a vital supportive therapy in critical care. However, both delayed weaning and premature discontinuation are associated with poor outcomes and prolonged ICU stay. Prolonged MV may lead to complications including respiratory muscle dysfunction, ventilator-associated lung injury, and increased healthcare costs, emphasizing the importance of optimal timing of weaning.

Ultrasonography (US) has emerged as a rapid, non-invasive bedside tool for real-time assessment of respiratory muscle function. It allows evaluation of muscle thickness and contractility, aiding in the detection of diaphragmatic dysfunction.

In cases of diaphragmatic impairment, accessory respiratory muscles, particularly the parasternal intercostal muscles, play a compensatory role. Measurement of parasternal intercostal muscle thickness fraction (PICTF%) has been proposed as a predictor of weaning failure.

Additionally, composite indices such as the rapid shallow breathing index (RSBI) and compliance, rate, oxygenation, and pressure (CROP) index are widely used to assess weaning readiness. A recently proposed composite index combining PICTF (>9%) and diaphragmatic excursion (<15 mm) demonstrated high predictive value for failure of non-invasive ventilation.

Therefore, the present study aims to evaluate the effectiveness of this novel composite index in predicting weaning failure in mechanically ventilated patients.

Visão geral do estudo

Status

Ainda não está recrutando

Tipo de estudo

Observacional

Inscrição (Estimado)

70

Critérios de participação

Os pesquisadores procuram pessoas que se encaixem em uma determinada descrição, chamada de critérios de elegibilidade. Alguns exemplos desses critérios são a condição geral de saúde de uma pessoa ou tratamentos anteriores.

Critérios de elegibilidade

Idades elegíveis para estudo

  • Adulto
  • Adulto mais velho

Aceita Voluntários Saudáveis

N/D

Método de amostragem

Amostra de Probabilidade

População do estudo

  • All the patients with difficulty in obtaining an appropriate ultrasound window (diaphragmatic paralysis/injury, ascites, thoracotomy, pneumothorax, pleural effusion, flail chest, and rib fractures).
  • Neuromuscular diseases.
  • Severe head injury.
  • Pregnant and lactating women.

Descrição

Inclusion Criteria:

  • Age ≥ 18 years old.
  • Both sexes.
  • Patients who have been mechanically ventilated for more than 48 h.

Exclusion Criteria:

  • All the patients with difficulty in obtaining an appropriate ultrasound window (diaphragmatic paralysis/injury, ascites, thoracotomy, pneumothorax, pleural effusion, flail chest, and rib fractures).
  • Neuromuscular diseases.
  • Severe head injury.
  • Pregnant and lactating women.

Plano de estudo

Esta seção fornece detalhes do plano de estudo, incluindo como o estudo é projetado e o que o estudo está medindo.

Como o estudo é projetado?

Detalhes do projeto

O que o estudo está medindo?

Medidas de resultados primários

Medida de resultado
Descrição da medida
Prazo
Ability of a combined PICTF% and diaphragmatic excursion to predict weaning failure .
Prazo: 5minutes after spontaneous breathing trail and after 5minutes of spontaneous breathing trail
Parasternal intercostal muscle thickening fraction (%) measured by ultrasound at 5 minutes after the start of the spontaneous breathing trial to evaluate its ability to predict weaning failure and diaphragmatic excursion
5minutes after spontaneous breathing trail and after 5minutes of spontaneous breathing trail

Medidas de resultados secundários

Medida de resultado
Prazo
• Difference between PICTF % at 5 and 60 min OF SBT. • RSBI at 5and 60 min of SBT. • Correlation between PICTF% and RSBI Diaphragmatic excursion
Prazo: at 5 mintues of spontanous breathing trail and at 60 minutes
at 5 mintues of spontanous breathing trail and at 60 minutes

Colaboradores e Investigadores

É aqui que você encontrará pessoas e organizações envolvidas com este estudo.

Patrocinador

Datas de registro do estudo

Essas datas acompanham o progresso do registro do estudo e os envios de resumo dos resultados para ClinicalTrials.gov. Os registros do estudo e os resultados relatados são revisados ​​pela National Library of Medicine (NLM) para garantir que atendam aos padrões específicos de controle de qualidade antes de serem publicados no site público.

Datas Principais do Estudo

Início do estudo (Estimado)

1 de setembro de 2026

Conclusão Primária (Estimado)

1 de janeiro de 2027

Conclusão do estudo (Estimado)

1 de junho de 2027

Datas de inscrição no estudo

Enviado pela primeira vez

22 de fevereiro de 2026

Enviado pela primeira vez que atendeu aos critérios de CQ

10 de julho de 2026

Primeira postagem (Real)

14 de julho de 2026

Atualizações de registro de estudo

Última Atualização Postada (Real)

18 de setembro de 2026

Última atualização enviada que atendeu aos critérios de controle de qualidade

17 de setembro de 2026

Última verificação

1 de julho de 2026

Mais Informações

Termos relacionados a este estudo

Palavras-chave

Outros números de identificação do estudo

  • md-461-2024

Informações sobre medicamentos e dispositivos, documentos de estudo

Estuda um medicamento regulamentado pela FDA dos EUA

Não

Estuda um produto de dispositivo regulamentado pela FDA dos EUA

Não

produto fabricado e exportado dos EUA

Não

Essas informações foram obtidas diretamente do site clinicaltrials.gov sem nenhuma alteração. Se você tiver alguma solicitação para alterar, remover ou atualizar os detalhes do seu estudo, entre em contato com register@clinicaltrials.gov. Assim que uma alteração for implementada em clinicaltrials.gov, ela também será atualizada automaticamente em nosso site .

Se inscrever