Подробное описание
To investigate whether raw impedance data from BIS measurements can be used as a tool to estimate changes in fluid status in HD patients. Accuracy is low when using prediction equations that are integrated into the individual BIS device. This challenges the application in clinical practice. Furthermore, the prediction equation is not available for most devices. Small studies suggest greater accuracy when using raw data, which could make BIS measurements clinically applicable. Detailed purpose. To examine whether raw impedance data from BIS measurements can be used as a tool to estimate changes in fluid status in HD patients.
- Ensure consistency in measurements of raw impedance data (Phase angle, RE, RI, R∞, and Cm) between different BIS devices (here: Fresenius BCM®, SFB7®, and SOZO® from ImpediMed).
- Compare intradialytic ∆RE, ∆R∞, and ∆Cm against changes in absolute blood volume, BP, weight, and fluid removal in HD patients with fluid removal.
- Is the phase angle consistent over the 3 dialysis days in a week for center dialysis patients with fluid retention?
- Compare intradialytic ∆RE, ∆R∞, and ∆Cm against changes in absolute blood volume, blood pressure, and weight in hemodialysis patients without fluid retention.
- Compare intradialytic ∆blood pressure, ∆weight, ∆ABV, fluid retention, and BIS measured changes (∆RE, ∆R∞, ∆Cm) for patients undergoing home hemodialysis with patients undergoing center hemodialysis.
Тип исследования
Регистрация (Оцененный)
Фаза
- Непригодный
Контакты и местонахождение
Контакты исследования
- Имя: Per Ivarsen, MD
- Номер телефона: +457845000
- Электронная почта: per.ivarsen@clin.au.dk
Места учебы
-
-
Central Denmark
-
Aarhus, Central Denmark, Дания, 8200
- Рекрутинг
- Aarhus University Hospital
-
Контакт:
- Per Ivarsen, MD
- Номер телефона: +457845000
- Электронная почта: per.ivarsen@clin.au.dk
-
Контакт:
- Электронная почта: per.ivarsen@clin.au.dk
-
Главный следователь:
- Per Ivarsen, MD
-
-
Критерии участия
Критерии приемлемости
Возраст, подходящий для обучения
- Взрослый
- Пожилой взрослый
Принимает здоровых добровольцев
Описание
Inclusion Criteria:
Hemodialysis for more than 3 month Hemodynamic stabile during a dialysis session
-
Exclusion Criteria:
- Amputated limbs.
- Pregnant.
- Extremity palsy and paralysis.
- Implanted electronic device (e.g., pacemaker or ICD).
- Regular use of dialysate sodium proliferation.
- Hip, knee and shoulder prosthesis.
- Dialysis fistula in both arms.
- Inability to give informed consent.
- History of discontinuation of dialysis treatment prematurely.
Учебный план
Как устроено исследование?
Детали дизайна
- Основная цель: Другой
- Распределение: Н/Д
- Интервенционная модель: Одногрупповое задание
- Маскировка: Нет (открытая этикетка)
Оружие и интервенции
Группа участников / Армия |
Вмешательство/лечение |
|---|---|
|
Активный компаратор: Hemodialysis patient
Measurement wil be donne before and after a hemodialysis.
Bioimpendance spectroscopy is measured with 3 different bioimpedance apperatur.
Absolute blood volumen is measured 5-10 minutes after starting and before stopping the dialysis session.
For center hemodialysis patients with ultrafiltration measurement til be performed on 3 consecutive days and for patient center hemodialysis patient meaurement wil be performed once with also apply for Home hemodialysis patients.
|
Comparing the perfomance of original data from 3 different bioimpedance apparatur and test there precision and accurary compared to ultrafiltration.
And whether the performance of measuring absolut blood volume is better
|
Что измеряет исследование?
Первичные показатели результатов
Мера результата |
Мера Описание |
Временное ограничение |
|---|---|---|
|
Changes in BIS measured resistance and fluid removed
Временное ограничение: From enrollment to the end of the dialysis session
|
To investigate whether raw impedance data from BIS measurements can be used as a tool to estimate changes in fluid status in HD patients before and after a hemodialysis session of 4 hours duration. Weight loss during a hemodialysis session is equivalent to fluid removed. The meausement are don for up to oen week
4) In a subset of patients test if the length of the of pause (days) between hemodialysis session influence the raw impedance measurements. |
From enrollment to the end of the dialysis session
|
Соавторы и исследователи
Спонсор
Даты записи исследования
Изучение основных дат
Начало исследования (Действительный)
Первичное завершение (Оцененный)
Завершение исследования (Оцененный)
Даты регистрации исследования
Первый отправленный
Впервые представлено, что соответствует критериям контроля качества
Первый опубликованный (Действительный)
Обновления учебных записей
Последнее опубликованное обновление (Действительный)
Последнее отправленное обновление, отвечающее критериям контроля качества
Последняя проверка
Дополнительная информация
Термины, связанные с этим исследованием
Ключевые слова
Дополнительные соответствующие термины MeSH
Другие идентификационные номера исследования
- VMK2500694
Планирование данных отдельных участников (IPD)
Планируете делиться данными об отдельных участниках (IPD)?
Информация о лекарствах и устройствах, исследовательские документы
Изучает лекарственный продукт, регулируемый FDA США.
Изучает продукт устройства, регулируемый Управлением по санитарному надзору за качеством пищевых продуктов и медикаментов США.
Эта информация была получена непосредственно с веб-сайта clinicaltrials.gov без каких-либо изменений. Если у вас есть запросы на изменение, удаление или обновление сведений об исследовании, обращайтесь по адресу register@clinicaltrials.gov. Как только изменение будет реализовано на clinicaltrials.gov, оно будет автоматически обновлено и на нашем веб-сайте. .