Evaluation of MRI Sequences in Hepatic Overload (HEPAT_MR)

10 mars 2021 uppdaterad av: Rennes University Hospital

Evaluation of MRI Sequences in Hepatic Overload.

MRI, without any contrast injection, allows a non-invasive evaluation and quantification of hepatic overloads, especially iron (liver iron content LIC) and fat (steatosis) overloads, but in certain clinical circumstances, cases require to improve performances. The aim of the study is to add to MRI scans which currently must be performed innovative sequences appropriate for the clinical question to overall appreciate on a varied range of patients their quality, their robustness, their relative performance and, for patients having a biopsy, their accuracy.

Studieöversikt

Status

Avslutad

Studietyp

Observationell

Inskrivning (Faktisk)

706

Kontakter och platser

Det här avsnittet innehåller kontaktuppgifter för dem som genomför studien och information om var denna studie genomförs.

Studieorter

      • Rennes, Frankrike, 35033
        • Rennes University Hospital

Deltagandekriterier

Forskare letar efter personer som passar en viss beskrivning, så kallade behörighetskriterier. Några exempel på dessa kriterier är en persons allmänna hälsotillstånd eller tidigare behandlingar.

Urvalskriterier

Åldrar som är berättigade till studier

18 år och äldre (Vuxen, Äldre vuxen)

Tar emot friska volontärer

Nej

Kön som är behöriga för studier

Allt

Testmetod

Icke-sannolikhetsprov

Studera befolkning

Patients with or suspected clinically to be with a hepatic overload pathology (hepatic iron and/or fat overload)

Beskrivning

Inclusion Criteria:

  • Men and women ≥ 18 years of age
  • Patients with or suspected clinically to be with a hepatic overload pathology (hepatic iron and/or fat overload) and who need a diagnostic or pre-therapeutic MRI from his initial management or during his monitoring,
  • Patient able to provide written informed consent and can understand and comply with the requirements of the study
  • Patient having received the information about the protocol and having not expressed his opposition to participate.

Exclusion Criteria:

Due to MRI :

  • pacemaker or defibrillator,
  • MRI non-compatible heart valve,
  • clips, stents, coils, etc… non-compatible with MRI,
  • cochlear implants,
  • neuronal or peripheric simulator,
  • intra-orbital or encephalic metallic foreign body, foreign body close to eyes, foreign body near the eyes, injury by metallic luster (war, ball),
  • endoprosthesis received since less than 4weeks and osteosynthesis equipment received since less than 6 weeks,
  • claustrophobia,
  • pump, tattoo, permanent make-up, intrauterine device, patch,
  • metal, magnetic, non-removable and in the area of the analyse field material

Other criteria :

  • unstable hemodynamic state, acute respiratory insufficiency, hemodynamically unstable acute respiratory failure, poor general condition or the necessity of a continuous monitoring incompatible with the MRI constraint,
  • adults legally protected (under judicial protection, guardianship, or supervision), persons deprived of their liberty,
  • pregnancy

Studieplan

Det här avsnittet ger detaljer om studieplanen, inklusive hur studien är utformad och vad studien mäter.

Hur är studien utformad?

Designdetaljer

Vad mäter studien?

Primära resultatmått

Resultatmått
Åtgärdsbeskrivning
Tidsram
Evaluation of the quantification deviations of hepatic iron and fat overloads between the new sequences and the conventional sequences.
Tidsram: 18 months
Evaluation of the robustness and the relative accuracy, comparison of sequences currently performed in daily clinical practice, of hepatic iron and fat content quantification with non-invasive new abdominal MRI sequences.
18 months

Sekundära resultatmått

Resultatmått
Åtgärdsbeskrivning
Tidsram
Analysis of the accuracy of quantification: of the iron concentration against biochemical, semi-quantitative histological or subtracted iron volume compared to the hepatic volume analysis
Tidsram: 18 months
Evaluation of the accuracy of these new MRI sequences for hepatic iron and fat quantification, when patients have had in their normal care and management a biopsy or a bleedings subtracted iron volume leading to a desaturation.
18 months

Samarbetspartners och utredare

Det är här du hittar personer och organisationer som är involverade i denna studie.

Studieavstämningsdatum

Dessa datum spårar framstegen för inlämningar av studieposter och sammanfattande resultat till ClinicalTrials.gov. Studieposter och rapporterade resultat granskas av National Library of Medicine (NLM) för att säkerställa att de uppfyller specifika kvalitetskontrollstandarder innan de publiceras på den offentliga webbplatsen.

Studera stora datum

Studiestart (Faktisk)

4 mars 2013

Primärt slutförande (Faktisk)

19 december 2018

Avslutad studie (Faktisk)

19 december 2018

Studieregistreringsdatum

Först inskickad

27 maj 2013

Först inskickad som uppfyllde QC-kriterierna

30 maj 2013

Första postat (Uppskatta)

31 maj 2013

Uppdateringar av studier

Senaste uppdatering publicerad (Faktisk)

11 mars 2021

Senaste inskickade uppdateringen som uppfyllde QC-kriterierna

10 mars 2021

Senast verifierad

1 mars 2020

Mer information

Termer relaterade till denna studie

Andra studie-ID-nummer

  • 2013-A00197-38

Denna information hämtades direkt från webbplatsen clinicaltrials.gov utan några ändringar. Om du har några önskemål om att ändra, ta bort eller uppdatera dina studieuppgifter, vänligen kontakta register@clinicaltrials.gov. Så snart en ändring har implementerats på clinicaltrials.gov, kommer denna att uppdateras automatiskt även på vår webbplats .

Prenumerera