- ICH GCP
- Amerikanska kliniska prövningsregistret
- Klinisk prövning NCT03357406
Conventional and Ultrasonic Implant Site Preparation (PI-DRI)
Immediate Loading After Conventional and Ultrasonic Implant Site Preparation: a Multicenter Randomized Controlled Clinical Trial
Studieöversikt
Status
Betingelser
Intervention / Behandling
Detaljerad beskrivning
Studietyp
Inskrivning (Faktisk)
Fas
- Inte tillämpbar
Kontakter och platser
Studieorter
-
-
-
Parma, Italien, 43100
- Piezosurgery Academy
-
-
Deltagandekriterier
Urvalskriterier
Åldrar som är berättigade till studier
Tar emot friska volontärer
Kön som är behöriga för studier
Beskrivning
Inclusion Criteria:
indications for two implant-supported single crowns with immediate loading in the upper or lower arch (in the incisor, canine or premolar area), based on accurate diagnosis and treatment planning; 2) implants can be in the same or in different quadrants; 3) implant sites must be performed in similar bone quality (i.e. both maxillary or mandibular); 4) the bone crest must be healed (at least three months elapsed after tooth loss); 5) presence of a residual bone crest with an adequate volume to allow the insertion of a 3.8x11.5 mm implant without any kind of regenerative procedure; 6) age of the patient >18 years; 7) patient willing and fully capable to comply with the study protocol; 8) written informed consent given;
Exclusion Criteria:
- acute myocardial infarction within the past 2 months;
- uncontrolled coagulation disorders;
- uncontrolled diabetes (HBA1c > 7.5%);
- radiotherapy to the head/neck district within the past 24 months;
- immunocompromised patient (HIV infection or chemotherapy within the past 5 years);
- present or past treatment with intravenous bisphosphonates;
- psychological or psychiatric problems;
- alcohol or drugs abuse Local exclusion criterion is the presence of uncontrolled or untreated periodontal disease (full mouth plaque score and full mouth bleeding score > 25%)
Studieplan
Hur är studien utformad?
Designdetaljer
- Primärt syfte: Behandling
- Tilldelning: Randomiserad
- Interventionsmodell: Enskild gruppuppgift
- Maskning: Dubbel
Vapen och interventioner
Deltagargrupp / Arm |
Intervention / Behandling |
|---|---|
|
Experimentell: edentulism side 1
ultrasound implant site preparation
|
piezoelectric bone surgery will be used to create implant bone ostectomy
|
|
Aktiv komparator: edentulism side 2
conventional implant site preparation
|
twist drills will be used to create implant bone ostectomy
|
Vad mäter studien?
Primära resultatmått
Resultatmått |
Åtgärdsbeskrivning |
Tidsram |
|---|---|---|
|
implant survival rate
Tidsram: two years after surgery
|
how many implant are present in mouth
|
two years after surgery
|
Sekundära resultatmått
Resultatmått |
Åtgärdsbeskrivning |
Tidsram |
|---|---|---|
|
implant success rate
Tidsram: two years after surgery
|
implant stable and fulfilling success criteria
|
two years after surgery
|
|
biomechanical complications
Tidsram: two years after surgery
|
every complication linked to the crown, implant abutment structure
|
two years after surgery
|
|
marginal bone loss
Tidsram: two years after surgery
|
radiographically assessed bone level
|
two years after surgery
|
Samarbetspartners och utredare
Utredare
- Studierektor: Claudio Stacchi, Dr, Piezosurgery Academy
Publikationer och användbara länkar
Allmänna publikationer
- Vercellotti T, Stacchi C, Russo C, Rebaudi A, Vincenzi G, Pratella U, Baldi D, Mozzati M, Monagheddu C, Sentineri R, Cuneo T, Di Alberti L, Carossa S, Schierano G. Ultrasonic implant site preparation using piezosurgery: a multicenter case series study analyzing 3,579 implants with a 1- to 3-year follow-up. Int J Periodontics Restorative Dent. 2014 Jan-Feb;34(1):11-8. doi: 10.11607/prd.1860.
- Esposito M, Grusovin MG, Achille H, Coulthard P, Worthington HV. Interventions for replacing missing teeth: different times for loading dental implants. Cochrane Database Syst Rev. 2009 Jan 21;(1):CD003878. doi: 10.1002/14651858.CD003878.pub4.
- Khayat PG, Arnal HM, Tourbah BI, Sennerby L. Clinical outcome of dental implants placed with high insertion torques (up to 176 Ncm). Clin Implant Dent Relat Res. 2013 Apr;15(2):227-33. doi: 10.1111/j.1708-8208.2011.00351.x. Epub 2011 May 20.
Studieavstämningsdatum
Studera stora datum
Studiestart (Faktisk)
Primärt slutförande (Faktisk)
Avslutad studie (Faktisk)
Studieregistreringsdatum
Först inskickad
Först inskickad som uppfyllde QC-kriterierna
Första postat (Faktisk)
Uppdateringar av studier
Senaste uppdatering publicerad (Faktisk)
Senaste inskickade uppdateringen som uppfyllde QC-kriterierna
Senast verifierad
Mer information
Termer relaterade till denna studie
Nyckelord
Ytterligare relevanta MeSH-villkor
Andra studie-ID-nummer
- piezo-drills
Plan för individuella deltagardata (IPD)
Planerar du att dela individuella deltagardata (IPD)?
Läkemedels- och apparatinformation, studiedokument
Studerar en amerikansk FDA-reglerad läkemedelsprodukt
Studerar en amerikansk FDA-reglerad produktprodukt
Denna information hämtades direkt från webbplatsen clinicaltrials.gov utan några ändringar. Om du har några önskemål om att ändra, ta bort eller uppdatera dina studieuppgifter, vänligen kontakta register@clinicaltrials.gov. Så snart en ändring har implementerats på clinicaltrials.gov, kommer denna att uppdateras automatiskt även på vår webbplats .