- ICH GCP
- Amerikanska kliniska prövningsregistret
- Klinisk prövning NCT07651033
3D Titanium Plates for Mandibular Parasymphyseal Fracture Fixation
The Use of 3d Titanium Plates With Two Different Profile Thickness for Open Reduction and Rigid Fixation of Mandibular Parasymphyseal Fracture:Randomised Clinical Trial
Mandibular fractures pose significant challenges in maxillofacial surgery due to their frequency, potential for functional impairment, and aesthetic concerns. Open reduction and internal fixation (ORIF) using titanium plates and screws have revolutionized the management of mandibular fractures.
The advent of 3D printing technology has ushered in a new era of patient-specific implants, offering improved adaptation to individual anatomy and potentially enhancing surgical outcomes.
Studieöversikt
Status
Betingelser
Intervention / Behandling
Detaljerad beskrivning
The face is the window through which we perceive the world around us, and the world noted us. It serves a crucial role in human interaction and injuries to it result in devastating emotional sequelae. The human face constitutes the first contact point in several human interactions, thus injuries and/or mutilation of the facial structures may have a disastrous influence on the affected person.
The facial area is one of the most frequently injured parts of the body, and the mandible is one of the most commonly fractured maxillofacial bones. For the past decades, there has been a significant increase in maxillofacial traumas involving mandible. They are mainly caused by vehicular accidents, sport activities, penetrating injuries, physical assault, work-related accident, metabolic diseases or tumors.
The position, prominence, anatomic configuration, mobility and less bone support of the mandible make it one of the most frequent facial bones to be fractured. The mandibular fracture accounts for 36% to 54% of all fractures in the maxillofacial region. Mandible is the 10th most fractured bone in the whole body. They may occur alone or in combination with other facial bone fractures.
It plays a major role in mastication, speech, and deglutition. Its fractures result in severe loss of function and disfigurement. Fractures through the mandible at the level of the Symphysis and or parasymphysis are relatively common and account for approximately 20% of mandibular fractures. These fractures are often associated with a second fracture of the mandible, especially in the subcondylar region.
Fractures of the symphyseal region are often associated with the clinical findings of a widened intragonial distance with resultant malocclusion. Fractures of the anterior mandible lack two of the stabilizing factors provided to fractures of the posterior tooth-bearing mandible: the splinting effects of the masseter and internal pterygoid muscles, which form a natural sling, and the interlocking cusps and fossae of bicuspid and molar teeth.
Internal fixation in long bones has been adapted with particular modifications for the mandible. The disadvantage with these rigid plates was movement of the fracture fragment while tightening the screws resulting in malocclusion. Also, these plates could only be minimally adapted to the fracture fragments and produced more tension on the bone resulting in loosening of screws. They also require an extraoral approach and are highly technique sensitive.
The introduction of the 3-dimension (3D) system for the treatment of mandibular fractures has offered certain advantages over other plating systems. These plates function as internal fixator, achieving stability by 3D plates. A unique advantage of 3D system is that there is no need to adapt plate over the underlying bone, making plate adaptation easier.
Theoretical advantages proposed include close approximation, greater stability across the fracture site, less precision required in plate adaptation because of the internal/external fixator, less alteration in osseous or occlusal relationship upon screw tightening and, and less time required.
Although several materials can be used for manufacture of small plates, generally titanium is used because of its excellent biocompatibility, resistance to corrosion and pliability. Champy's miniplates require intra oral approach, less technique sensitive and produce consistently good results with regard to occlusion and also avoid the need for intermaxillary fixation
Studietyp
Inskrivning (Faktisk)
Fas
- Inte tillämpbar
Kontakter och platser
Studieorter
-
-
Giza Governorate
-
Cairo, Giza Governorate, Egypten
- Dentistery Hospital, Cairo Universiy
-
-
Deltagandekriterier
Urvalskriterier
Åldrar som är berättigade till studier
- Vuxen
Tar emot friska volontärer
Beskrivning
Inclusion Criteria:
- Age ranging between 20-60 years.
- Patients with mandibular parasymphyseal fractures requiring open reduction and fixation..
- Patients with good health (ASA -I and ASA- II) without any contraindication for surgery or anesthesia.
Exclusion Criteria:
- Patients with pre existing neurological or musculoskeletal disease.
- Patients with infected fractures.
- Patients with simultaneous condylar fracture.
- Patients with regional malignancy.
- Medically compromised patients.
- Patients with blood diseases or severe renal disorders.
- Patients refuse to share in the study.
Studieplan
Hur är studien utformad?
Designdetaljer
- Primärt syfte: Behandling
- Tilldelning: Randomiserad
- Interventionsmodell: Parallellt uppdrag
- Maskning: Ingen (Open Label)
Vapen och interventioner
Deltagargrupp / Arm |
Intervention / Behandling |
|---|---|
|
Aktiv komparator: Group A (3d titanium plates of 2 mm):
About 9 patients suffered from Mandibular Parasymphyseal Fracture treated by using 3d titanium plates of 2 mm thickness.
|
to compare 3d titanium plates with two different profile thickness for open reduction and rigid fixation of mandibular parasymphyseal fracture.
Andra namn:
|
|
Aktiv komparator: Group B (3d titanium plates of 0.7 mm):
About 9 patients suffered from Mandibular Parasymphyseal Fracture treated by using 3d titanium plates of 0.7 mm thickness.
|
to compare 3d titanium plates with two different profile thickness for open reduction and rigid fixation of mandibular parasymphyseal fracture.
Andra namn:
|
Vad mäter studien?
Primära resultatmått
Resultatmått |
Åtgärdsbeskrivning |
Tidsram |
|---|---|---|
|
Treatment of Postoperative pain
Tidsram: 48 Hours from the operation
|
Treatment of the pain resulted from using 3d titanium plates with two different profile thickness for open reduction and fixation of mandibular Parasymphyseal fracture by using a standardized pain scale.
|
48 Hours from the operation
|
Sekundära resultatmått
Resultatmått |
Åtgärdsbeskrivning |
Tidsram |
|---|---|---|
|
Incidence of postoperative Complications
Tidsram: from1 week to 6 months
|
Secondary outcomes will be evaluated to assess the clinical effectiveness and safety of using 3D titanium plates with different profile thicknesses in the fixation of mandibular body fractures (as infection, malocclusion, and hardwarerelated complications).
|
from1 week to 6 months
|
Samarbetspartners och utredare
Sponsor
Utredare
- Studiestol: Mohamed Atef, Professor, Oral and Maxillofacial Surgery, Faculty of Dentistry, Kasr Al-Aini
Studieavstämningsdatum
Studera stora datum
Studiestart (Faktisk)
Primärt slutförande (Faktisk)
Avslutad studie (Faktisk)
Studieregistreringsdatum
Först inskickad
Först inskickad som uppfyllde QC-kriterierna
Första postat (Faktisk)
Uppdateringar av studier
Senaste uppdatering publicerad (Faktisk)
Senaste inskickade uppdateringen som uppfyllde QC-kriterierna
Senast verifierad
Mer information
Termer relaterade till denna studie
Ytterligare relevanta MeSH-villkor
Andra studie-ID-nummer
- Mandibular Fracture
Plan för individuella deltagardata (IPD)
Planerar du att dela individuella deltagardata (IPD)?
Läkemedels- och apparatinformation, studiedokument
Studerar en amerikansk FDA-reglerad läkemedelsprodukt
Studerar en amerikansk FDA-reglerad produktprodukt
Denna information hämtades direkt från webbplatsen clinicaltrials.gov utan några ändringar. Om du har några önskemål om att ändra, ta bort eller uppdatera dina studieuppgifter, vänligen kontakta register@clinicaltrials.gov. Så snart en ändring har implementerats på clinicaltrials.gov, kommer denna att uppdateras automatiskt även på vår webbplats .