Application of Medical Imaging Procedures in Surgery Implanting in Cancerology With the Aim to Reduce Invasive Acts (ATIM)
2011年6月21日 更新者:Centre Leon Berard
Aero digestive Cancer patients treated by external head and neck radiotherapy and/or by curie-therapy and/or mandible reconstruction by microanastomosed fibula flaps.
The purpose of the study is to Investigate the accuracy of implants insertion in the anteroposterior way, using radiosurgical guidance.
研究概览
详细说明
- Investigate the accuracy of inserting implants in the vertical way and in angulation, on irradiated native mandible or on microanastomosed fibula flaps
- Investigate the accuracy of inserting implants in the anteroposterior way, in the vertical way and in angulation for all the involved patients (meaning on irradiated native mandible or on microanastomosed fibula flaps)
- Investigate the delay of mucous healing
- Estimate the prosthetic function
- Evaluate the osteonecrosis rate after radiation with traumatic etiology due to implantation
- Estimate the implant rate due to minimally invasive flaps
- Estimate the implant rate due to pure trans mucosa way
- Estimate the post surgical therapeutic success after 1 year
研究类型
介入性
注册 (预期的)
53
阶段
- 不适用
联系人和位置
本节提供了进行研究的人员的详细联系信息,以及有关进行该研究的地点的信息。
学习地点
-
-
-
Clermont-ferrand、法国、63 000
- CHU Hôtel-Dieu Service d'Odontologie
-
Lyon、法国、69007
- Hospices Civils de Lyon Service de Consultations et Traitements Dentaires
-
Pierre Benite、法国、69495
- Centre Hospitalier Lyon Sud Service de Stomatologie et Chirurgie Maxillo-Faciale
-
-
Cedex 08
-
Lyon、Cedex 08、法国、69373
- Centre Léon Bérard Service de Chirurgie-Stomatologie
-
-
参与标准
研究人员寻找符合特定描述的人,称为资格标准。这些标准的一些例子是一个人的一般健康状况或先前的治疗。
资格标准
适合学习的年龄
18年 及以上 (成人、年长者)
接受健康志愿者
不
有资格学习的性别
全部
描述
Inclusion Criteria:
- age over 18
- Performance status over 70
- Histological evidence of upper digestive tract cancer
- History of cranial / facial radiotherapy or brachytherapy and/or microvascular fibula transfer.
- Bone volume sufficient to support an implant.
- Mandatory affiliation with a social security system
- Written, voluntary, informed consent
Exclusion Criteria:
- Patient with evolutive malignant disease
- Contraindication to general anesthesia
- Concurrent disease contra-indicating implant surgery (risk of infectious endocarditis, uncontrolled diabetes, HIV, evolutive neoplasia…)
- Patient enrolled in another clinical trial including chemotherapy
- Pregnant or lactating woman
- Anticipation of an impossible follow-up
- Patient deprived of freedom
学习计划
本节提供研究计划的详细信息,包括研究的设计方式和研究的衡量标准。
研究是如何设计的?
设计细节
- 主要用途:支持治疗
- 分配:不适用
- 介入模型:单组作业
- 屏蔽:无(打开标签)
研究衡量的是什么?
主要结果指标
结果测量 |
大体时间 |
|---|---|
|
Accuracy of implants insertion, radio-surgical guidance.
大体时间:8 months after inclusion
|
8 months after inclusion
|
次要结果测量
结果测量 |
大体时间 |
|---|---|
|
Accuracy of inserting implants
大体时间:16 months after inclusion
|
16 months after inclusion
|
|
Delay of mucous healing
大体时间:16 months after inclusion
|
16 months after inclusion
|
|
Estimation of the prosthetic function
大体时间:16 months after inclusion
|
16 months after inclusion
|
|
Osteonecrosis rate after radiation with traumatic etiology due to implantation
大体时间:16 months after inclusion
|
16 months after inclusion
|
|
Implant rate
大体时间:16 months after inclusion
|
16 months after inclusion
|
|
Post surgical therapeutic success after 1 year
大体时间:after 1 year
|
after 1 year
|
合作者和调查者
在这里您可以找到参与这项研究的人员和组织。
调查人员
- 首席研究员:Anne-Gaëlle BODARD, MD、Centre Léon Bérard
出版物和有用的链接
负责输入研究信息的人员自愿提供这些出版物。这些可能与研究有关。
一般刊物
- Beumer J 3rd, Roumanas E, Nishimura R. Advances in osseointegrated implants for dental and facial rehabilitation following major head and neck surgery. Semin Surg Oncol. 1995 May-Jun;11(3):200-7. doi: 10.1002/ssu.2980110305.
- Birkfellner W, Solar P, Gahleitner A, Huber K, Kainberger F, Kettenbach J, Homolka P, Diemling M, Watzek G, Bergmann H. In-vitro assessment of a registration protocol for image guided implant dentistry. Clin Oral Implants Res. 2001 Feb;12(1):69-78. doi: 10.1034/j.1600-0501.2001.012001069.x.
- Brosky ME, Korioth TW, Hodges J. The anterior cantilever in the implant-supported screw-retained mandibular prosthesis. J Prosthet Dent. 2003 Mar;89(3):244-9. doi: 10.1067/mpr.2003.43.
- Casap N, Wexler A, Persky N, Schneider A, Lustmann J. Navigation surgery for dental implants: assessment of accuracy of the image guided implantology system. J Oral Maxillofac Surg. 2004 Sep;62(9 Suppl 2):116-9. doi: 10.1016/j.joms.2004.06.028.
- Casap N, Wexler A, Tarazi E. Application of a surgical navigation system for implant surgery in a deficient alveolar ridge postexcision of an odontogenic myxoma. J Oral Maxillofac Surg. 2005 Jul;63(7):982-8. doi: 10.1016/j.joms.2005.03.015.
- Delannes M, Daly NJ, Bonnet J, Sabatier J, Tremoulet M. Fractionated radiotherapy of small inoperable lesions of the brain using a non-invasive stereotactic frame. Int J Radiat Oncol Biol Phys. 1991 Aug;21(3):749-55. doi: 10.1016/0360-3016(91)90695-z.
- Esser E, Wagner W. Dental implants following radical oral cancer surgery and adjuvant radiotherapy. Int J Oral Maxillofac Implants. 1997 Jul-Aug;12(4):552-7.
- Esser E, Neukirchen S, Wagner W. [Comparative studies of Branemark implants in the irradiated and not irradiated mandible]. Mund Kiefer Gesichtschir. 1999 May;3 Suppl 1:S125-9. doi: 10.1007/PL00014498. German.
- Fortin T, Coudert JL, Champleboux G, Sautot P, Lavallee S. Computer-assisted dental implant surgery using computed tomography. J Image Guid Surg. 1995;1(1):53-8. doi: 10.1002/(SICI)1522-712X(1995)1:13.0.CO;2-L.
- Fortin T, Champleboux G, Lormee J, Coudert JL. Precise dental implant placement in bone using surgical guides in conjunction with medical imaging techniques. J Oral Implantol. 2000;26(4):300-3. doi: 10.1563/1548-1336(2000)0262.3.CO;2.
- Fortin T, Champleboux G, Bianchi S, Buatois H, Coudert JL. Precision of transfer of preoperative planning for oral implants based on cone-beam CT-scan images through a robotic drilling machine. Clin Oral Implants Res. 2002 Dec;13(6):651-6. doi: 10.1034/j.1600-0501.2002.130612.x.
- Fortin T, Bosson JL, Coudert JL, Isidori M. Reliability of preoperative planning of an image-guided system for oral implant placement based on 3-dimensional images: an in vivo study. Int J Oral Maxillofac Implants. 2003 Nov-Dec;18(6):886-93.
- Fortin T, Isidori M, Blanchet E, Perriat M, Bouchet H, Coudert JL. An image-guided system-drilled surgical template and trephine guide pin to make treatment of completely edentulous patients easier: a clinical report on immediate loading. Clin Implant Dent Relat Res. 2004;6(2):111-9. doi: 10.1111/j.1708-8208.2004.tb00033.x.
- Ganslandt O, Mueller R, Mueller W, Borchert H, Grabenbauer GG. Simple invasive fixation device for fractionated stereotactic LINAC based radiotherapy. Acta Neurochir (Wien). 2003 Apr;145(4):289-94; discussion 294. doi: 10.1007/s00701-003-0002-9.
- Gill SS, Thomas DG, Warrington AP, Brada M. Relocatable frame for stereotactic external beam radiotherapy. Int J Radiat Oncol Biol Phys. 1991 Mar;20(3):599-603. doi: 10.1016/0360-3016(91)90076-g.
- Gulizio MP, Agar JR, Kelly JR, Taylor TD. Effect of implant angulation upon retention of overdenture attachments. J Prosthodont. 2005 Mar;14(1):3-11. doi: 10.1111/j.1532-849X.2005.00005.x.
- Henderson LA, Frysinger RC, Yu PL, Bandler R, Harper RM. A device for feline head positioning and stabilization during magnetic resonance imaging. Magn Reson Imaging. 2001 Sep;19(7):1031-6. doi: 10.1016/s0730-725x(01)00423-4.
- Kamath R, Ryken TC, Meeks SL, Pennington EC, Ritchie J, Buatti JM. Initial clinical experience with frameless radiosurgery for patients with intracranial metastases. Int J Radiat Oncol Biol Phys. 2005 Apr 1;61(5):1467-72. doi: 10.1016/j.ijrobp.2004.08.021.
- Kassaee A, Das IJ, Tochner Z, Rosenthal DI. Modification of Gill-Thomas-Cosman frame for extracranial head-and-neck stereotactic radiotherapy. Int J Radiat Oncol Biol Phys. 2003 Nov 15;57(4):1192-5. doi: 10.1016/s0360-3016(03)00774-0.
- Marunick MT, Leveque F. Osteoradionecrosis related to mastication and parafunction. Oral Surg Oral Med Oral Pathol. 1989 Nov;68(5):582-5. doi: 10.1016/0030-4220(89)90244-2.
- Medin PM, Solberg TD, De Salles AA, Cagnon CH, Selch MT, Johnson JP, Smathers JB, Cosman ER. Investigations of a minimally invasive method for treatment of spinal malignancies with LINAC stereotactic radiation therapy: accuracy and animal studies. Int J Radiat Oncol Biol Phys. 2002 Mar 15;52(4):1111-22. doi: 10.1016/s0360-3016(01)02762-6.
- Parel SM, Triplett RG. Interactive imaging for implant planning, placement, and prosthesis construction. J Oral Maxillofac Surg. 2004 Sep;62(9 Suppl 2):41-7. doi: 10.1016/j.joms.2004.05.207.
- Quinones-Hinojosa A, Ware ML, Sanai N, McDermott MW. Assessment of image guided accuracy in a skull model: comparison of frameless stereotaxy techniques vs. frame-based localization. J Neurooncol. 2006 Jan;76(1):65-70. doi: 10.1007/s11060-005-2915-z.
- Rosenberg I, Alheit H, Beardmore C, Lee KS, Warrington AP, Brada M. Patient position reproducibility in fractionated stereotactic radiotherapy: an update after changing dental impression material. Radiother Oncol. 1999 Feb;50(2):239-40. doi: 10.1016/s0167-8140(99)00002-x.
- Rosenthal SJ, Gall KP, Jackson M, Thornton AF Jr. A precision cranial immobilization system for conformal stereotactic fractionated radiation therapy. Int J Radiat Oncol Biol Phys. 1995 Dec 1;33(5):1239-45. doi: 10.1016/0360-3016(95)02009-8.
- Scott TW, Beach JL, Mendiondo OA. A precision repeat localization head frame for fractionated stereotactic radiotherapy. Med Dosim. 1997 Spring;22(1):5-8. doi: 10.1016/s0958-3947(96)00148-3.
- Siessegger M, Schneider BT, Mischkowski RA, Lazar F, Krug B, Klesper B, Zoller JE. Use of an image-guided navigation system in dental implant surgery in anatomically complex operation sites. J Craniomaxillofac Surg. 2001 Oct;29(5):276-81. doi: 10.1054/jcms.2001.0242.
- Sudbrink SD. Computer-guided implant placement with immediate provisionalization: a case report. J Oral Maxillofac Surg. 2005 Jun;63(6):771-4. doi: 10.1016/j.joms.2005.02.011.
- Theodorou K, Kappas C, Tsokas C. A new non-invasive and relocatable immobilization frame for fractionated stereotactic radiotherapy. Radiother Oncol. 1998 Jun;47(3):313-7. doi: 10.1016/s0167-8140(98)00015-2.
- Van Steenberghe D, Malevez C, Van Cleynenbreugel J, Bou Serhal C, Dhoore E, Schutyser F, Suetens P, Jacobs R. Accuracy of drilling guides for transfer from three-dimensional CT-based planning to placement of zygoma implants in human cadavers. Clin Oral Implants Res. 2003 Feb;14(1):131-6. doi: 10.1034/j.1600-0501.2003.140118.x.
- Vrielinck L, Politis C, Schepers S, Pauwels M, Naert I. Image-based planning and clinical validation of zygoma and pterygoid implant placement in patients with severe bone atrophy using customized drill guides. Preliminary results from a prospective clinical follow-up study. Int J Oral Maxillofac Surg. 2003 Feb;32(1):7-14. doi: 10.1054/ijom.2002.0337.
- Wagner A, Wanschitz F, Birkfellner W, Zauza K, Klug C, Schicho K, Kainberger F, Czerny C, Bergmann H, Ewers R. Computer-aided placement of endosseous oral implants in patients after ablative tumour surgery: assessment of accuracy. Clin Oral Implants Res. 2003 Jun;14(3):340-8. doi: 10.1034/j.1600-0501.2003.110812.x.
- Watzinger F, Ewers R, Henninger A, Sudasch G, Babka A, Woelfl G. Endosteal implants in the irradiated lower jaw. J Craniomaxillofac Surg. 1996 Aug;24(4):237-44. doi: 10.1016/s1010-5182(96)80007-2.
- Weischer T, Schettler D, Mohr C. Implant-supported telescopic restorations in maxillofacial prosthetics. Int J Prosthodont. 1997 May-Jun;10(3):287-92.
- Weischer T, Mohr C. Ten-year experience in oral implant rehabilitation of cancer patients: treatment concept and proposed criteria for success. Int J Oral Maxillofac Implants. 1999 Jul-Aug;14(4):521-8.
- Weischer T, Mohr C. Implant-supported mandibular telescopic prostheses in oral cancer patients: an up to 9-year retrospective study. Int J Prosthodont. 2001 Jul-Aug;14(4):329-34.
- Widmann G, Widmann R, Widmann E, Jaschke W, Bale RJ. In vitro accuracy of a novel registration and targeting technique for image-guided template production. Clin Oral Implants Res. 2005 Aug;16(4):502-8. doi: 10.1111/j.1600-0501.2005.01131.x.
- Kooy HM, Dunbar SF, Tarbell NJ, Mannarino E, Ferarro N, Shusterman S, Bellerive M, Finn L, McDonough CV, Loeffler JS. Adaptation and verification of the relocatable Gill-Thomas-Cosman frame in stereotactic radiotherapy. Int J Radiat Oncol Biol Phys. 1994 Oct 15;30(3):685-91. doi: 10.1016/0360-3016(92)90956-i.
研究记录日期
这些日期跟踪向 ClinicalTrials.gov 提交研究记录和摘要结果的进度。研究记录和报告的结果由国家医学图书馆 (NLM) 审查,以确保它们在发布到公共网站之前符合特定的质量控制标准。
研究主要日期
学习开始
2007年9月1日
初级完成 (预期的)
2011年12月1日
研究完成 (预期的)
2011年12月1日
研究注册日期
首次提交
2009年6月2日
首先提交符合 QC 标准的
2009年6月19日
首次发布 (估计)
2009年6月22日
研究记录更新
最后更新发布 (估计)
2011年6月22日
上次提交的符合 QC 标准的更新
2011年6月21日
最后验证
2011年6月1日
更多信息
与本研究相关的术语
此信息直接从 clinicaltrials.gov 网站检索,没有任何更改。如果您有任何更改、删除或更新研究详细信息的请求,请联系 register@clinicaltrials.gov. clinicaltrials.gov 上实施更改,我们的网站上也会自动更新.