Prospective Randomized Trial of Navigated and Conventional TKA
Prospective Randomized Trial of Navigated and Conventional TKA With Radiographic and CT Evaluations
研究概览
详细说明
Component position, kinematics After skin closure lateral x-rays were done in different flexion angles in order to evaluate the kinematic behaviour of the TKA.
A full-length standing and a lateral radiograph as well as CT scans of the hip, knee and ankle joint were performed 5 to 7 days postoperatively before discharge.
- clinical outcome Patient sociodemographic and anamnestic data were collected. The written interview was complemented by the EuroQol questionnaire (release EQ-5D) and the assessment of the patients' functional status (Knee Society Score) one week before surgery and 18 to 24 month after surgery.
研究类型
注册 (实际的)
阶段
- 不适用
联系人和位置
学习地点
-
-
-
Dresden、德国、01307
- University Hospital Dresden, Orthopaedic Department
-
-
参与标准
资格标准
适合学习的年龄
接受健康志愿者
有资格学习的性别
描述
Inclusion Criteria:
- primary or secondary osteoarthritis of the knee
- indication to TKA
- a mechanical axis between 20° varus and 5° valgus
- signed informed consent
Exclusion Criteria:
- previous hemi- or total arthroplasty
- severe instability that could not be treated with an unconstrained, cruciate-retaining TKA
学习计划
研究是如何设计的?
设计细节
- 主要用途:治疗
- 分配:随机化
- 介入模型:并行分配
- 屏蔽:无(打开标签)
武器和干预
参与者组/臂 |
干预/治疗 |
|---|---|
|
有源比较器:navigated TKA
|
In all patients a cemented, unconstrained, cruciate-retaining TKA with a rotating platform (ScorpioTM PCS, Stryker Orthopaedics, Mahwah, NJ) was implanted. No patellar resurfacing was performed. A medial parapatellar approach with a femur-first preparation was done in all cases. The Stryker Navigation System, Knee Navigation Software V3.1 (Stryker Orthopaedics, Mahwah, NJ) was used for computer-assisted implantation. The conventional implantation was performed with femoral intramedullary and tibial extramedullary standard alignment guides.
其他名称:
|
|
其他:conventional TKA
|
In all patients a cemented, unconstrained, cruciate-retaining TKA with a rotating platform (ScorpioTM PCS, Stryker Orthopaedics, Mahwah, NJ) was implanted. No patellar resurfacing was performed. A medial parapatellar approach with a femur-first preparation was done in all cases. The Stryker Navigation System, Knee Navigation Software V3.1 (Stryker Orthopaedics, Mahwah, NJ) was used for computer-assisted implantation. The conventional implantation was performed with femoral intramedullary and tibial extramedullary standard alignment guides.
其他名称:
|
研究衡量的是什么?
主要结果指标
结果测量 |
大体时间 |
|---|---|
|
rotational component position
大体时间:postoperatively
|
postoperatively
|
次要结果测量
结果测量 |
大体时间 |
|---|---|
|
leg axis
大体时间:postoperatively
|
postoperatively
|
|
kinematics
大体时间:postoperatively
|
postoperatively
|
|
clinical outcome
大体时间:18 to 24 month postoperatively
|
18 to 24 month postoperatively
|
合作者和调查者
调查人员
- 研究主任:Klaus-Peter Günther, MD, PhD、Orthopaedic Department, University Hospital Dresden
出版物和有用的链接
一般刊物
- Lutzner J, Krummenauer F, Wolf C, Gunther KP, Kirschner S. Computer-assisted and conventional total knee replacement: a comparative, prospective, randomised study with radiological and CT evaluation. J Bone Joint Surg Br. 2008 Aug;90(8):1039-44. doi: 10.1302/0301-620X.90B8.20553.
- Beyer F, Pape A, Lutzner C, Kirschner S, Lutzner J. Similar outcomes in computer-assisted and conventional total knee arthroplasty: ten-year results of a prospective randomized study. BMC Musculoskelet Disord. 2021 Aug 18;22(1):707. doi: 10.1186/s12891-021-04556-3.
- Harman MK, Banks SA, Kirschner S, Lutzner J. Prosthesis alignment affects axial rotation motion after total knee replacement: a prospective in vivo study combining computed tomography and fluoroscopic evaluations. BMC Musculoskelet Disord. 2012 Oct 23;13:206. doi: 10.1186/1471-2474-13-206.
- Lutzner J, Krummenauer F, Gunther KP, Kirschner S. Rotational alignment of the tibial component in total knee arthroplasty is better at the medial third of tibial tuberosity than at the medial border. BMC Musculoskelet Disord. 2010 Mar 25;11:57. doi: 10.1186/1471-2474-11-57.
研究记录日期
研究主要日期
学习开始
初级完成 (实际的)
研究完成 (实际的)
研究注册日期
首次提交
首先提交符合 QC 标准的
首次发布 (估计)
研究记录更新
最后更新发布 (估计)
上次提交的符合 QC 标准的更新
最后验证
更多信息
此信息直接从 clinicaltrials.gov 网站检索,没有任何更改。如果您有任何更改、删除或更新研究详细信息的请求,请联系 register@clinicaltrials.gov. clinicaltrials.gov 上实施更改,我们的网站上也会自动更新.