- ICH GCP
- Yhdysvaltain kliinisten tutkimusten rekisteri
- Kliininen tutkimus NCT01022099
Prospective Randomized Trial of Navigated and Conventional TKA
Prospective Randomized Trial of Navigated and Conventional TKA With Radiographic and CT Evaluations
Tutkimuksen yleiskatsaus
Tila
Ehdot
Interventio / Hoito
Yksityiskohtainen kuvaus
Component position, kinematics After skin closure lateral x-rays were done in different flexion angles in order to evaluate the kinematic behaviour of the TKA.
A full-length standing and a lateral radiograph as well as CT scans of the hip, knee and ankle joint were performed 5 to 7 days postoperatively before discharge.
- clinical outcome Patient sociodemographic and anamnestic data were collected. The written interview was complemented by the EuroQol questionnaire (release EQ-5D) and the assessment of the patients' functional status (Knee Society Score) one week before surgery and 18 to 24 month after surgery.
Opintotyyppi
Ilmoittautuminen (Todellinen)
Vaihe
- Ei sovellettavissa
Yhteystiedot ja paikat
Opiskelupaikat
-
-
-
Dresden, Saksa, 01307
- University Hospital Dresden, Orthopaedic Department
-
-
Osallistumiskriteerit
Kelpoisuusvaatimukset
Opintokelpoiset iät
Hyväksyy terveitä vapaaehtoisia
Sukupuolet, jotka voivat opiskella
Kuvaus
Inclusion Criteria:
- primary or secondary osteoarthritis of the knee
- indication to TKA
- a mechanical axis between 20° varus and 5° valgus
- signed informed consent
Exclusion Criteria:
- previous hemi- or total arthroplasty
- severe instability that could not be treated with an unconstrained, cruciate-retaining TKA
Opintosuunnitelma
Miten tutkimus on suunniteltu?
Suunnittelun yksityiskohdat
- Ensisijainen käyttötarkoitus: Hoito
- Jako: Satunnaistettu
- Inventiomalli: Rinnakkaistehtävä
- Naamiointi: Ei mitään (avoin tarra)
Aseet ja interventiot
Osallistujaryhmä / Arm |
Interventio / Hoito |
|---|---|
|
Active Comparator: navigated TKA
|
In all patients a cemented, unconstrained, cruciate-retaining TKA with a rotating platform (ScorpioTM PCS, Stryker Orthopaedics, Mahwah, NJ) was implanted. No patellar resurfacing was performed. A medial parapatellar approach with a femur-first preparation was done in all cases. The Stryker Navigation System, Knee Navigation Software V3.1 (Stryker Orthopaedics, Mahwah, NJ) was used for computer-assisted implantation. The conventional implantation was performed with femoral intramedullary and tibial extramedullary standard alignment guides.
Muut nimet:
|
|
Muut: conventional TKA
|
In all patients a cemented, unconstrained, cruciate-retaining TKA with a rotating platform (ScorpioTM PCS, Stryker Orthopaedics, Mahwah, NJ) was implanted. No patellar resurfacing was performed. A medial parapatellar approach with a femur-first preparation was done in all cases. The Stryker Navigation System, Knee Navigation Software V3.1 (Stryker Orthopaedics, Mahwah, NJ) was used for computer-assisted implantation. The conventional implantation was performed with femoral intramedullary and tibial extramedullary standard alignment guides.
Muut nimet:
|
Mitä tutkimuksessa mitataan?
Ensisijaiset tulostoimenpiteet
Tulosmittaus |
Aikaikkuna |
|---|---|
|
rotational component position
Aikaikkuna: postoperatively
|
postoperatively
|
Toissijaiset tulostoimenpiteet
Tulosmittaus |
Aikaikkuna |
|---|---|
|
leg axis
Aikaikkuna: postoperatively
|
postoperatively
|
|
kinematics
Aikaikkuna: postoperatively
|
postoperatively
|
|
clinical outcome
Aikaikkuna: 18 to 24 month postoperatively
|
18 to 24 month postoperatively
|
Yhteistyökumppanit ja tutkijat
Sponsori
Tutkijat
- Opintojohtaja: Klaus-Peter Günther, MD, PhD, Orthopaedic Department, University Hospital Dresden
Julkaisuja ja hyödyllisiä linkkejä
Yleiset julkaisut
- Lutzner J, Krummenauer F, Wolf C, Gunther KP, Kirschner S. Computer-assisted and conventional total knee replacement: a comparative, prospective, randomised study with radiological and CT evaluation. J Bone Joint Surg Br. 2008 Aug;90(8):1039-44. doi: 10.1302/0301-620X.90B8.20553.
- Beyer F, Pape A, Lutzner C, Kirschner S, Lutzner J. Similar outcomes in computer-assisted and conventional total knee arthroplasty: ten-year results of a prospective randomized study. BMC Musculoskelet Disord. 2021 Aug 18;22(1):707. doi: 10.1186/s12891-021-04556-3.
- Harman MK, Banks SA, Kirschner S, Lutzner J. Prosthesis alignment affects axial rotation motion after total knee replacement: a prospective in vivo study combining computed tomography and fluoroscopic evaluations. BMC Musculoskelet Disord. 2012 Oct 23;13:206. doi: 10.1186/1471-2474-13-206.
- Lutzner J, Krummenauer F, Gunther KP, Kirschner S. Rotational alignment of the tibial component in total knee arthroplasty is better at the medial third of tibial tuberosity than at the medial border. BMC Musculoskelet Disord. 2010 Mar 25;11:57. doi: 10.1186/1471-2474-11-57.
Opintojen ennätyspäivät
Opi tärkeimmät päivämäärät
Opiskelun aloitus
Ensisijainen valmistuminen (Todellinen)
Opintojen valmistuminen (Todellinen)
Opintoihin ilmoittautumispäivät
Ensimmäinen lähetetty
Ensimmäinen toimitettu, joka täytti QC-kriteerit
Ensimmäinen Lähetetty (Arvio)
Tutkimustietojen päivitykset
Viimeisin päivitys julkaistu (Arvio)
Viimeisin lähetetty päivitys, joka täytti QC-kriteerit
Viimeksi vahvistettu
Lisää tietoa
Tähän tutkimukseen liittyvät termit
Avainsanat
Muita asiaankuuluvia MeSH-ehtoja
Muut tutkimustunnusnumerot
- KneeNavy
Nämä tiedot haettiin suoraan verkkosivustolta clinicaltrials.gov ilman muutoksia. Jos sinulla on pyyntöjä muuttaa, poistaa tai päivittää tutkimustietojasi, ota yhteyttä register@clinicaltrials.gov. Heti kun muutos on otettu käyttöön osoitteessa clinicaltrials.gov, se päivitetään automaattisesti myös verkkosivustollemme .