- ICH GCP
- Register voor klinische proeven in de VS.
- Klinische proef NCT01022099
Prospective Randomized Trial of Navigated and Conventional TKA
Prospective Randomized Trial of Navigated and Conventional TKA With Radiographic and CT Evaluations
Studie Overzicht
Toestand
Conditie
Interventie / Behandeling
Gedetailleerde beschrijving
Component position, kinematics After skin closure lateral x-rays were done in different flexion angles in order to evaluate the kinematic behaviour of the TKA.
A full-length standing and a lateral radiograph as well as CT scans of the hip, knee and ankle joint were performed 5 to 7 days postoperatively before discharge.
- clinical outcome Patient sociodemographic and anamnestic data were collected. The written interview was complemented by the EuroQol questionnaire (release EQ-5D) and the assessment of the patients' functional status (Knee Society Score) one week before surgery and 18 to 24 month after surgery.
Studietype
Inschrijving (Werkelijk)
Fase
- Niet toepasbaar
Contacten en locaties
Studie Locaties
-
-
-
Dresden, Duitsland, 01307
- University Hospital Dresden, Orthopaedic Department
-
-
Deelname Criteria
Geschiktheidscriteria
Leeftijden die in aanmerking komen voor studie
Accepteert gezonde vrijwilligers
Geslachten die in aanmerking komen voor studie
Beschrijving
Inclusion Criteria:
- primary or secondary osteoarthritis of the knee
- indication to TKA
- a mechanical axis between 20° varus and 5° valgus
- signed informed consent
Exclusion Criteria:
- previous hemi- or total arthroplasty
- severe instability that could not be treated with an unconstrained, cruciate-retaining TKA
Studie plan
Hoe is de studie opgezet?
Ontwerpdetails
- Primair doel: Behandeling
- Toewijzing: Gerandomiseerd
- Interventioneel model: Parallelle opdracht
- Masker: Geen (open label)
Wapens en interventies
Deelnemersgroep / Arm |
Interventie / Behandeling |
|---|---|
|
Actieve vergelijker: navigated TKA
|
In all patients a cemented, unconstrained, cruciate-retaining TKA with a rotating platform (ScorpioTM PCS, Stryker Orthopaedics, Mahwah, NJ) was implanted. No patellar resurfacing was performed. A medial parapatellar approach with a femur-first preparation was done in all cases. The Stryker Navigation System, Knee Navigation Software V3.1 (Stryker Orthopaedics, Mahwah, NJ) was used for computer-assisted implantation. The conventional implantation was performed with femoral intramedullary and tibial extramedullary standard alignment guides.
Andere namen:
|
|
Ander: conventional TKA
|
In all patients a cemented, unconstrained, cruciate-retaining TKA with a rotating platform (ScorpioTM PCS, Stryker Orthopaedics, Mahwah, NJ) was implanted. No patellar resurfacing was performed. A medial parapatellar approach with a femur-first preparation was done in all cases. The Stryker Navigation System, Knee Navigation Software V3.1 (Stryker Orthopaedics, Mahwah, NJ) was used for computer-assisted implantation. The conventional implantation was performed with femoral intramedullary and tibial extramedullary standard alignment guides.
Andere namen:
|
Wat meet het onderzoek?
Primaire uitkomstmaten
Uitkomstmaat |
Tijdsspanne |
|---|---|
|
rotational component position
Tijdsspanne: postoperatively
|
postoperatively
|
Secundaire uitkomstmaten
Uitkomstmaat |
Tijdsspanne |
|---|---|
|
leg axis
Tijdsspanne: postoperatively
|
postoperatively
|
|
kinematics
Tijdsspanne: postoperatively
|
postoperatively
|
|
clinical outcome
Tijdsspanne: 18 to 24 month postoperatively
|
18 to 24 month postoperatively
|
Medewerkers en onderzoekers
Sponsor
Onderzoekers
- Studie directeur: Klaus-Peter Günther, MD, PhD, Orthopaedic Department, University Hospital Dresden
Publicaties en nuttige links
Algemene publicaties
- Lutzner J, Krummenauer F, Wolf C, Gunther KP, Kirschner S. Computer-assisted and conventional total knee replacement: a comparative, prospective, randomised study with radiological and CT evaluation. J Bone Joint Surg Br. 2008 Aug;90(8):1039-44. doi: 10.1302/0301-620X.90B8.20553.
- Beyer F, Pape A, Lutzner C, Kirschner S, Lutzner J. Similar outcomes in computer-assisted and conventional total knee arthroplasty: ten-year results of a prospective randomized study. BMC Musculoskelet Disord. 2021 Aug 18;22(1):707. doi: 10.1186/s12891-021-04556-3.
- Harman MK, Banks SA, Kirschner S, Lutzner J. Prosthesis alignment affects axial rotation motion after total knee replacement: a prospective in vivo study combining computed tomography and fluoroscopic evaluations. BMC Musculoskelet Disord. 2012 Oct 23;13:206. doi: 10.1186/1471-2474-13-206.
- Lutzner J, Krummenauer F, Gunther KP, Kirschner S. Rotational alignment of the tibial component in total knee arthroplasty is better at the medial third of tibial tuberosity than at the medial border. BMC Musculoskelet Disord. 2010 Mar 25;11:57. doi: 10.1186/1471-2474-11-57.
Studie record data
Bestudeer belangrijke data
Studie start
Primaire voltooiing (Werkelijk)
Studie voltooiing (Werkelijk)
Studieregistratiedata
Eerst ingediend
Eerst ingediend dat voldeed aan de QC-criteria
Eerst geplaatst (Schatting)
Updates van studierecords
Laatste update geplaatst (Schatting)
Laatste update ingediend die voldeed aan QC-criteria
Laatst geverifieerd
Meer informatie
Termen gerelateerd aan deze studie
Trefwoorden
Aanvullende relevante MeSH-voorwaarden
Andere studie-ID-nummers
- KneeNavy
Deze informatie is zonder wijzigingen rechtstreeks van de website clinicaltrials.gov gehaald. Als u verzoeken heeft om uw onderzoeksgegevens te wijzigen, te verwijderen of bij te werken, neem dan contact op met register@clinicaltrials.gov. Zodra er een wijziging wordt doorgevoerd op clinicaltrials.gov, wordt deze ook automatisch bijgewerkt op onze website .