Prospective Randomized Trial of Navigated and Conventional TKA
Prospective Randomized Trial of Navigated and Conventional TKA With Radiographic and CT Evaluations
Panoramica dello studio
Stato
Condizioni
Intervento / Trattamento
Descrizione dettagliata
Component position, kinematics After skin closure lateral x-rays were done in different flexion angles in order to evaluate the kinematic behaviour of the TKA.
A full-length standing and a lateral radiograph as well as CT scans of the hip, knee and ankle joint were performed 5 to 7 days postoperatively before discharge.
- clinical outcome Patient sociodemographic and anamnestic data were collected. The written interview was complemented by the EuroQol questionnaire (release EQ-5D) and the assessment of the patients' functional status (Knee Society Score) one week before surgery and 18 to 24 month after surgery.
Tipo di studio
Iscrizione (Effettivo)
Fase
- Non applicabile
Contatti e Sedi
Luoghi di studio
-
-
-
Dresden, Germania, 01307
- University Hospital Dresden, Orthopaedic Department
-
-
Criteri di partecipazione
Criteri di ammissibilità
Età idonea allo studio
Accetta volontari sani
Sessi ammissibili allo studio
Descrizione
Inclusion Criteria:
- primary or secondary osteoarthritis of the knee
- indication to TKA
- a mechanical axis between 20° varus and 5° valgus
- signed informed consent
Exclusion Criteria:
- previous hemi- or total arthroplasty
- severe instability that could not be treated with an unconstrained, cruciate-retaining TKA
Piano di studio
Come è strutturato lo studio?
Dettagli di progettazione
- Scopo principale: Trattamento
- Assegnazione: Randomizzato
- Modello interventistico: Assegnazione parallela
- Mascheramento: Nessuno (etichetta aperta)
Armi e interventi
Gruppo di partecipanti / Arm |
Intervento / Trattamento |
|---|---|
|
Comparatore attivo: navigated TKA
|
In all patients a cemented, unconstrained, cruciate-retaining TKA with a rotating platform (ScorpioTM PCS, Stryker Orthopaedics, Mahwah, NJ) was implanted. No patellar resurfacing was performed. A medial parapatellar approach with a femur-first preparation was done in all cases. The Stryker Navigation System, Knee Navigation Software V3.1 (Stryker Orthopaedics, Mahwah, NJ) was used for computer-assisted implantation. The conventional implantation was performed with femoral intramedullary and tibial extramedullary standard alignment guides.
Altri nomi:
|
|
Altro: conventional TKA
|
In all patients a cemented, unconstrained, cruciate-retaining TKA with a rotating platform (ScorpioTM PCS, Stryker Orthopaedics, Mahwah, NJ) was implanted. No patellar resurfacing was performed. A medial parapatellar approach with a femur-first preparation was done in all cases. The Stryker Navigation System, Knee Navigation Software V3.1 (Stryker Orthopaedics, Mahwah, NJ) was used for computer-assisted implantation. The conventional implantation was performed with femoral intramedullary and tibial extramedullary standard alignment guides.
Altri nomi:
|
Cosa sta misurando lo studio?
Misure di risultato primarie
Misura del risultato |
Lasso di tempo |
|---|---|
|
rotational component position
Lasso di tempo: postoperatively
|
postoperatively
|
Misure di risultato secondarie
Misura del risultato |
Lasso di tempo |
|---|---|
|
leg axis
Lasso di tempo: postoperatively
|
postoperatively
|
|
kinematics
Lasso di tempo: postoperatively
|
postoperatively
|
|
clinical outcome
Lasso di tempo: 18 to 24 month postoperatively
|
18 to 24 month postoperatively
|
Collaboratori e investigatori
Sponsor
Investigatori
- Direttore dello studio: Klaus-Peter Günther, MD, PhD, Orthopaedic Department, University Hospital Dresden
Pubblicazioni e link utili
Pubblicazioni generali
- Lutzner J, Krummenauer F, Wolf C, Gunther KP, Kirschner S. Computer-assisted and conventional total knee replacement: a comparative, prospective, randomised study with radiological and CT evaluation. J Bone Joint Surg Br. 2008 Aug;90(8):1039-44. doi: 10.1302/0301-620X.90B8.20553.
- Beyer F, Pape A, Lutzner C, Kirschner S, Lutzner J. Similar outcomes in computer-assisted and conventional total knee arthroplasty: ten-year results of a prospective randomized study. BMC Musculoskelet Disord. 2021 Aug 18;22(1):707. doi: 10.1186/s12891-021-04556-3.
- Harman MK, Banks SA, Kirschner S, Lutzner J. Prosthesis alignment affects axial rotation motion after total knee replacement: a prospective in vivo study combining computed tomography and fluoroscopic evaluations. BMC Musculoskelet Disord. 2012 Oct 23;13:206. doi: 10.1186/1471-2474-13-206.
- Lutzner J, Krummenauer F, Gunther KP, Kirschner S. Rotational alignment of the tibial component in total knee arthroplasty is better at the medial third of tibial tuberosity than at the medial border. BMC Musculoskelet Disord. 2010 Mar 25;11:57. doi: 10.1186/1471-2474-11-57.
Studiare le date dei record
Studia le date principali
Inizio studio
Completamento primario (Effettivo)
Completamento dello studio (Effettivo)
Date di iscrizione allo studio
Primo inviato
Primo inviato che soddisfa i criteri di controllo qualità
Primo Inserito (Stima)
Aggiornamenti dei record di studio
Ultimo aggiornamento pubblicato (Stima)
Ultimo aggiornamento inviato che soddisfa i criteri QC
Ultimo verificato
Maggiori informazioni
Termini relativi a questo studio
Parole chiave
Termini MeSH pertinenti aggiuntivi
Altri numeri di identificazione dello studio
- KneeNavy
Queste informazioni sono state recuperate direttamente dal sito web clinicaltrials.gov senza alcuna modifica. In caso di richieste di modifica, rimozione o aggiornamento dei dettagli dello studio, contattare register@clinicaltrials.gov. Non appena verrà implementata una modifica su clinicaltrials.gov, questa verrà aggiornata automaticamente anche sul nostro sito web .
Prove cliniche su Implantation of a Total Knee Arthroplasty
-
Zimmer BiometCompletatoArtrite reumatoide | Dolore al ginocchio | Osteoartrosi cronica | Necrosi avascolare del condilo femorale | Deformità moderate in varo, valgo o flessioneBelgio, Svizzera, Germania, Israele, Italia
-
Archus Orthopedics, Inc.SconosciutoLombalgia | Malattie della colonna vertebrale | Stenosi spinale lombare | Stenosi spinale | Spondilolistesi | Dolore alla gamba
-
DePuy InternationalAttivo, non reclutanteMalattia articolare degenerativa non infiammatoriaStati Uniti, Hong Kong, Malaysia, Australia, Austria, Belgio, Canada, Germania, Nuova Zelanda, Singapore, Regno Unito, Corea del Sud
-
Stryker OrthopaedicsCompletatoProtesi totale di ginocchioDanimarca, Finlandia, Germania, Spagna
-
Stryker OrthopaedicsTerminatoArtroplastica, Sostituzione, GinocchioLussemburgo, Germania, Regno Unito
-
Smith & Nephew, Inc.Nor ConsultCompletatoSistema di ginocchio totale Journey II CRStati Uniti
-
Stryker South PacificTerminatoMalattia articolare degenerativa non infiammatoriaAustralia
-
Zimmer BiometCompletato
-
Stryker South PacificAttivo, non reclutante
-
Stryker OrthopaedicsCompletatoArtroplastica, Sostituzione, GinocchioOlanda, Regno Unito, Austria, Germania