此页面是自动翻译的,不保证翻译的准确性。请参阅 英文版 对于源文本。

Optimal Number of To-and-fro Motion in EUS-guided Fine Needle Aspiration for Pancreatic Masses

2014年5月28日 更新者:Do Hyun Park、Asan Medical Center

Optimal Number of To-and-fro Motion in EUS-guided Fine Needle Aspiration for Pancreatic Masses in Terms of Suction or Without Suction: Prospective Randomized Single Blinded Trial

EUS-FNA is the standard of care for diagnosing pancreatic masses. According to the operator's preference, EUS-FNA with suction or without suction technique has been used. To date, little is known about optimal number of to-and-fro motion during each needle pass. As usual 10-15 to-and-fro motions was used for EUS-FNA with suction technique. Theoretically, more number of to-and-fro motions may be required in EUS-FNA without suction. In this circumstance, the contamination of blood in specimen and possible adverse event may occur. To determine optimal number of to-and-fro motion in EUS-guided FNA for pancreatic masses in terms of with suction or without suction, this prospective single-blinded randomized trial was conducted.

研究概览

详细说明

For this prospective single-blinded randomized trial, two 10cc syringes was prepared. Two syringe was provided as same performance. However, one syringe is falsely made as suction syringe (fake one). During EUS-FNA, two syringe is randomly assigned and loaded by a nurse. Thus, operator was blinded which syringe is with suction or without suction.

First hypothesis: There is difference in the diagnostic accuracy of pancreatic masses according to EUS-FNA with suction or without suction/ different number of to-and-fro motion.

Second hypothesis: There is difference in the amount of blood in samples obtained by EUS-FNA with suction or without suction/ different number of to-and-fro motion.

研究类型

介入性

注册 (实际的)

193

阶段

  • 第三阶段

联系人和位置

本节提供了进行研究的人员的详细联系信息,以及有关进行该研究的地点的信息。

学习地点

      • Seoul、大韩民国、138-736
        • Asan Medical Center

参与标准

研究人员寻找符合特定描述的人,称为资格标准。这些标准的一些例子是一个人的一般健康状况或先前的治疗。

资格标准

适合学习的年龄

18年 至 85年 (成人、年长者)

接受健康志愿者

不

有资格学习的性别

全部

描述

Inclusion Criteria:

  • Age > 19 years Solid pancreatic mass lesions

Exclusion Criteria:

  • Age < 19 years Coagulopathy Unable to consent

学习计划

本节提供研究计划的详细信息,包括研究的设计方式和研究的衡量标准。

研究是如何设计的?

设计细节

  • 主要用途:诊断
  • 分配:随机化
  • 介入模型:并行分配
  • 屏蔽:双倍的

武器和干预

参与者组/臂
干预/治疗
有源比较器:EUS-FNA with suction
EUS-FNA with suction/10, 15, 20 to-and-fro motion vs. EUS-FNA with suction/10, 15, 20 to-and-fro motion Visual assessment as stoping rule: 20 to-and-fro motion at different site will be performed when EUS-FNA sampling with 10, 15, 20 to-and-fro motion is unsatisfactory.
For this prospective single-blinded randomized trial, two 10cc syringes was prepared. Two syringe was provided as same performance. However, one syringe is falsely made as suction syringe (fake one). During EUS-FNA, two syringe is randomly assigned and loaded by a nurse. Thus, operator was blinded which syringe is with suction or without suction.
其他名称:
  • FNA with suction
有源比较器:EUS-FNA without suction
EUS-FNA with suction/10, 15, 20 to-and-fro motion vs. EUS-FNA without suction/10, 15, 20 to-and-fro motion Visual assessment as stoping rule: 20 to-and-fro motion at different site will be performed when EUS-FNA sampling with 10, 15, 20 to-and-fro motion is unsatisfactory.
EUS-FNA with suction/10, 15, 20 to-and-fro motion vs. EUS-FNA without suction/10, 15, 20 to-and-fro motion Visual assessment as stoping rule: 20 to-and-fro motion at different site will be performed when EUS-FNA sampling with 10, 15, 20 to-and-fro motion is unsatisfactory.
其他名称:
  • FNA with or without suction
For this prospective single-blinded randomized trial, two 10cc syringes was prepared. Two syringe was provided as same performance. However, one syringe is falsely made as suction syringe (fake one). During EUS-FNA, two syringe is randomly assigned and loaded by a nurse. Thus, operator was blinded which syringe is with suction or without suction.
其他名称:
  • FNA without suction

研究衡量的是什么?

主要结果指标

结果测量
措施说明
大体时间
Diagnostic accuracy
大体时间:1 year

The diagnostic accuracy of pancreatic masses at each sample according to EUS-FNA with suction or without suction/ different number of to-and-fro motion will be measured.

Diagnostic accuracy of EUS-FNA with suction and 10, 15, and 20 to-and-fro motion vs.Diagnostic accuracy of EUS-FNA without suction and 10, 15, and 20 to-and-fro motion.

1 year

次要结果测量

结果测量
措施说明
大体时间
Blood contamination in each sample
大体时间:1 year

The amount of blood contamination at each sample according to EUS-FNA with suction or without suction/ different number of to-and-fro motion will be measured.

The amount of blood contamination of EUS-FNA with suction and 10, 15, and 20 to-and-fro motion vs. The amount of blood contamination of EUS-FNA without suction and 10, 15, and 20 to-and-fro motion.

1 year

合作者和调查者

在这里您可以找到参与这项研究的人员和组织。

调查人员

  • 首席研究员:Do Hyun Park, MD, PhD、Asan Medical Center

研究记录日期

这些日期跟踪向 ClinicalTrials.gov 提交研究记录和摘要结果的进度。研究记录和报告的结果由国家医学图书馆 (NLM) 审查,以确保它们在发布到公共网站之前符合特定的质量控制标准。

研究主要日期

学习开始

2012年4月1日

初级完成 (实际的)

2012年10月1日

研究完成 (实际的)

2013年3月1日

研究注册日期

首次提交

2012年4月7日

首先提交符合 QC 标准的

2012年4月11日

首次发布 (估计)

2012年4月12日

研究记录更新

最后更新发布 (估计)

2014年5月29日

上次提交的符合 QC 标准的更新

2014年5月28日

最后验证

2012年4月1日

更多信息

与本研究相关的术语

其他研究编号

  • 2012-0018

此信息直接从 clinicaltrials.gov 网站检索,没有任何更改。如果您有任何更改、删除或更新研究详细信息的请求,请联系 register@clinicaltrials.gov. clinicaltrials.gov 上实施更改,我们的网站上也会自动更新.

订阅