Optimal Number of To-and-fro Motion in EUS-guided Fine Needle Aspiration for Pancreatic Masses
Optimal Number of To-and-fro Motion in EUS-guided Fine Needle Aspiration for Pancreatic Masses in Terms of Suction or Without Suction: Prospective Randomized Single Blinded Trial
Studieoversikt
Status
Forhold
Intervensjon / Behandling
Detaljert beskrivelse
For this prospective single-blinded randomized trial, two 10cc syringes was prepared. Two syringe was provided as same performance. However, one syringe is falsely made as suction syringe (fake one). During EUS-FNA, two syringe is randomly assigned and loaded by a nurse. Thus, operator was blinded which syringe is with suction or without suction.
First hypothesis: There is difference in the diagnostic accuracy of pancreatic masses according to EUS-FNA with suction or without suction/ different number of to-and-fro motion.
Second hypothesis: There is difference in the amount of blood in samples obtained by EUS-FNA with suction or without suction/ different number of to-and-fro motion.
Studietype
Registrering (Faktiske)
Fase
- Fase 3
Kontakter og plasseringer
Studiesteder
-
-
-
Seoul, Korea, Republikken, 138-736
- Asan Medical Center
-
-
Deltakelseskriterier
Kvalifikasjonskriterier
Alder som er kvalifisert for studier
Tar imot friske frivillige
Kjønn som er kvalifisert for studier
Beskrivelse
Inclusion Criteria:
- Age > 19 years Solid pancreatic mass lesions
Exclusion Criteria:
- Age < 19 years Coagulopathy Unable to consent
Studieplan
Hvordan er studiet utformet?
Designdetaljer
- Primært formål: Diagnostisk
- Tildeling: Randomisert
- Intervensjonsmodell: Parallell tildeling
- Masking: Dobbelt
Våpen og intervensjoner
Deltakergruppe / Arm |
Intervensjon / Behandling |
|---|---|
|
Aktiv komparator: EUS-FNA with suction
EUS-FNA with suction/10, 15, 20 to-and-fro motion vs. EUS-FNA with suction/10, 15, 20 to-and-fro motion Visual assessment as stoping rule: 20 to-and-fro motion at different site will be performed when EUS-FNA sampling with 10, 15, 20 to-and-fro motion is unsatisfactory.
|
For this prospective single-blinded randomized trial, two 10cc syringes was prepared.
Two syringe was provided as same performance.
However, one syringe is falsely made as suction syringe (fake one).
During EUS-FNA, two syringe is randomly assigned and loaded by a nurse.
Thus, operator was blinded which syringe is with suction or without suction.
Andre navn:
|
|
Aktiv komparator: EUS-FNA without suction
EUS-FNA with suction/10, 15, 20 to-and-fro motion vs. EUS-FNA without suction/10, 15, 20 to-and-fro motion Visual assessment as stoping rule: 20 to-and-fro motion at different site will be performed when EUS-FNA sampling with 10, 15, 20 to-and-fro motion is unsatisfactory.
|
EUS-FNA with suction/10, 15, 20 to-and-fro motion vs. EUS-FNA without suction/10, 15, 20 to-and-fro motion Visual assessment as stoping rule: 20 to-and-fro motion at different site will be performed when EUS-FNA sampling with 10, 15, 20 to-and-fro motion is unsatisfactory.
Andre navn:
For this prospective single-blinded randomized trial, two 10cc syringes was prepared.
Two syringe was provided as same performance.
However, one syringe is falsely made as suction syringe (fake one).
During EUS-FNA, two syringe is randomly assigned and loaded by a nurse.
Thus, operator was blinded which syringe is with suction or without suction.
Andre navn:
|
Hva måler studien?
Primære resultatmål
Resultatmål |
Tiltaksbeskrivelse |
Tidsramme |
|---|---|---|
|
Diagnostic accuracy
Tidsramme: 1 year
|
The diagnostic accuracy of pancreatic masses at each sample according to EUS-FNA with suction or without suction/ different number of to-and-fro motion will be measured. Diagnostic accuracy of EUS-FNA with suction and 10, 15, and 20 to-and-fro motion vs.Diagnostic accuracy of EUS-FNA without suction and 10, 15, and 20 to-and-fro motion. |
1 year
|
Sekundære resultatmål
Resultatmål |
Tiltaksbeskrivelse |
Tidsramme |
|---|---|---|
|
Blood contamination in each sample
Tidsramme: 1 year
|
The amount of blood contamination at each sample according to EUS-FNA with suction or without suction/ different number of to-and-fro motion will be measured. The amount of blood contamination of EUS-FNA with suction and 10, 15, and 20 to-and-fro motion vs. The amount of blood contamination of EUS-FNA without suction and 10, 15, and 20 to-and-fro motion. |
1 year
|
Samarbeidspartnere og etterforskere
Sponsor
Etterforskere
- Hovedetterforsker: Do Hyun Park, MD, PhD, Asan Medical Center
Studierekorddatoer
Studer hoveddatoer
Studiestart
Primær fullføring (Faktiske)
Studiet fullført (Faktiske)
Datoer for studieregistrering
Først innsendt
Først innsendt som oppfylte QC-kriteriene
Først lagt ut (Anslag)
Oppdateringer av studieposter
Sist oppdatering lagt ut (Anslag)
Siste oppdatering sendt inn som oppfylte QC-kriteriene
Sist bekreftet
Mer informasjon
Begreper knyttet til denne studien
Nøkkelord
Andre studie-ID-numre
- 2012-0018
Denne informasjonen ble hentet direkte fra nettstedet clinicaltrials.gov uten noen endringer. Hvis du har noen forespørsler om å endre, fjerne eller oppdatere studiedetaljene dine, vennligst kontakt register@clinicaltrials.gov. Så snart en endring er implementert på clinicaltrials.gov, vil denne også bli oppdatert automatisk på nettstedet vårt. .