- ICH GCP
- Register voor klinische proeven in de VS.
- Klinische proef NCT01576497
Optimal Number of To-and-fro Motion in EUS-guided Fine Needle Aspiration for Pancreatic Masses
Optimal Number of To-and-fro Motion in EUS-guided Fine Needle Aspiration for Pancreatic Masses in Terms of Suction or Without Suction: Prospective Randomized Single Blinded Trial
Studie Overzicht
Toestand
Conditie
Interventie / Behandeling
Gedetailleerde beschrijving
For this prospective single-blinded randomized trial, two 10cc syringes was prepared. Two syringe was provided as same performance. However, one syringe is falsely made as suction syringe (fake one). During EUS-FNA, two syringe is randomly assigned and loaded by a nurse. Thus, operator was blinded which syringe is with suction or without suction.
First hypothesis: There is difference in the diagnostic accuracy of pancreatic masses according to EUS-FNA with suction or without suction/ different number of to-and-fro motion.
Second hypothesis: There is difference in the amount of blood in samples obtained by EUS-FNA with suction or without suction/ different number of to-and-fro motion.
Studietype
Inschrijving (Werkelijk)
Fase
- Fase 3
Contacten en locaties
Studie Locaties
-
-
-
Seoul, Korea, republiek van, 138-736
- Asan Medical Center
-
-
Deelname Criteria
Geschiktheidscriteria
Leeftijden die in aanmerking komen voor studie
Accepteert gezonde vrijwilligers
Geslachten die in aanmerking komen voor studie
Beschrijving
Inclusion Criteria:
- Age > 19 years Solid pancreatic mass lesions
Exclusion Criteria:
- Age < 19 years Coagulopathy Unable to consent
Studie plan
Hoe is de studie opgezet?
Ontwerpdetails
- Primair doel: Diagnostisch
- Toewijzing: Gerandomiseerd
- Interventioneel model: Parallelle opdracht
- Masker: Dubbele
Wapens en interventies
Deelnemersgroep / Arm |
Interventie / Behandeling |
|---|---|
|
Actieve vergelijker: EUS-FNA with suction
EUS-FNA with suction/10, 15, 20 to-and-fro motion vs. EUS-FNA with suction/10, 15, 20 to-and-fro motion Visual assessment as stoping rule: 20 to-and-fro motion at different site will be performed when EUS-FNA sampling with 10, 15, 20 to-and-fro motion is unsatisfactory.
|
For this prospective single-blinded randomized trial, two 10cc syringes was prepared.
Two syringe was provided as same performance.
However, one syringe is falsely made as suction syringe (fake one).
During EUS-FNA, two syringe is randomly assigned and loaded by a nurse.
Thus, operator was blinded which syringe is with suction or without suction.
Andere namen:
|
|
Actieve vergelijker: EUS-FNA without suction
EUS-FNA with suction/10, 15, 20 to-and-fro motion vs. EUS-FNA without suction/10, 15, 20 to-and-fro motion Visual assessment as stoping rule: 20 to-and-fro motion at different site will be performed when EUS-FNA sampling with 10, 15, 20 to-and-fro motion is unsatisfactory.
|
EUS-FNA with suction/10, 15, 20 to-and-fro motion vs. EUS-FNA without suction/10, 15, 20 to-and-fro motion Visual assessment as stoping rule: 20 to-and-fro motion at different site will be performed when EUS-FNA sampling with 10, 15, 20 to-and-fro motion is unsatisfactory.
Andere namen:
For this prospective single-blinded randomized trial, two 10cc syringes was prepared.
Two syringe was provided as same performance.
However, one syringe is falsely made as suction syringe (fake one).
During EUS-FNA, two syringe is randomly assigned and loaded by a nurse.
Thus, operator was blinded which syringe is with suction or without suction.
Andere namen:
|
Wat meet het onderzoek?
Primaire uitkomstmaten
Uitkomstmaat |
Maatregel Beschrijving |
Tijdsspanne |
|---|---|---|
|
Diagnostic accuracy
Tijdsspanne: 1 year
|
The diagnostic accuracy of pancreatic masses at each sample according to EUS-FNA with suction or without suction/ different number of to-and-fro motion will be measured. Diagnostic accuracy of EUS-FNA with suction and 10, 15, and 20 to-and-fro motion vs.Diagnostic accuracy of EUS-FNA without suction and 10, 15, and 20 to-and-fro motion. |
1 year
|
Secundaire uitkomstmaten
Uitkomstmaat |
Maatregel Beschrijving |
Tijdsspanne |
|---|---|---|
|
Blood contamination in each sample
Tijdsspanne: 1 year
|
The amount of blood contamination at each sample according to EUS-FNA with suction or without suction/ different number of to-and-fro motion will be measured. The amount of blood contamination of EUS-FNA with suction and 10, 15, and 20 to-and-fro motion vs. The amount of blood contamination of EUS-FNA without suction and 10, 15, and 20 to-and-fro motion. |
1 year
|
Medewerkers en onderzoekers
Sponsor
Onderzoekers
- Hoofdonderzoeker: Do Hyun Park, MD, PhD, Asan Medical Center
Studie record data
Bestudeer belangrijke data
Studie start
Primaire voltooiing (Werkelijk)
Studie voltooiing (Werkelijk)
Studieregistratiedata
Eerst ingediend
Eerst ingediend dat voldeed aan de QC-criteria
Eerst geplaatst (Schatting)
Updates van studierecords
Laatste update geplaatst (Schatting)
Laatste update ingediend die voldeed aan QC-criteria
Laatst geverifieerd
Meer informatie
Termen gerelateerd aan deze studie
Trefwoorden
Andere studie-ID-nummers
- 2012-0018
Deze informatie is zonder wijzigingen rechtstreeks van de website clinicaltrials.gov gehaald. Als u verzoeken heeft om uw onderzoeksgegevens te wijzigen, te verwijderen of bij te werken, neem dan contact op met register@clinicaltrials.gov. Zodra er een wijziging wordt doorgevoerd op clinicaltrials.gov, wordt deze ook automatisch bijgewerkt op onze website .