Optimal Number of To-and-fro Motion in EUS-guided Fine Needle Aspiration for Pancreatic Masses
Optimal Number of To-and-fro Motion in EUS-guided Fine Needle Aspiration for Pancreatic Masses in Terms of Suction or Without Suction: Prospective Randomized Single Blinded Trial
Aperçu de l'étude
Statut
Les conditions
Intervention / Traitement
Description détaillée
For this prospective single-blinded randomized trial, two 10cc syringes was prepared. Two syringe was provided as same performance. However, one syringe is falsely made as suction syringe (fake one). During EUS-FNA, two syringe is randomly assigned and loaded by a nurse. Thus, operator was blinded which syringe is with suction or without suction.
First hypothesis: There is difference in the diagnostic accuracy of pancreatic masses according to EUS-FNA with suction or without suction/ different number of to-and-fro motion.
Second hypothesis: There is difference in the amount of blood in samples obtained by EUS-FNA with suction or without suction/ different number of to-and-fro motion.
Type d'étude
Inscription (Réel)
Phase
- Phase 3
Contacts et emplacements
Lieux d'étude
-
-
-
Seoul, Corée, République de, 138-736
- Asan Medical Center
-
-
Critères de participation
Critère d'éligibilité
Âges éligibles pour étudier
Accepte les volontaires sains
Sexes éligibles pour l'étude
La description
Inclusion Criteria:
- Age > 19 years Solid pancreatic mass lesions
Exclusion Criteria:
- Age < 19 years Coagulopathy Unable to consent
Plan d'étude
Comment l'étude est-elle conçue ?
Détails de conception
- Objectif principal: Diagnostique
- Répartition: Randomisé
- Modèle interventionnel: Affectation parallèle
- Masquage: Double
Armes et Interventions
Groupe de participants / Bras |
Intervention / Traitement |
|---|---|
|
Comparateur actif: EUS-FNA with suction
EUS-FNA with suction/10, 15, 20 to-and-fro motion vs. EUS-FNA with suction/10, 15, 20 to-and-fro motion Visual assessment as stoping rule: 20 to-and-fro motion at different site will be performed when EUS-FNA sampling with 10, 15, 20 to-and-fro motion is unsatisfactory.
|
For this prospective single-blinded randomized trial, two 10cc syringes was prepared.
Two syringe was provided as same performance.
However, one syringe is falsely made as suction syringe (fake one).
During EUS-FNA, two syringe is randomly assigned and loaded by a nurse.
Thus, operator was blinded which syringe is with suction or without suction.
Autres noms:
|
|
Comparateur actif: EUS-FNA without suction
EUS-FNA with suction/10, 15, 20 to-and-fro motion vs. EUS-FNA without suction/10, 15, 20 to-and-fro motion Visual assessment as stoping rule: 20 to-and-fro motion at different site will be performed when EUS-FNA sampling with 10, 15, 20 to-and-fro motion is unsatisfactory.
|
EUS-FNA with suction/10, 15, 20 to-and-fro motion vs. EUS-FNA without suction/10, 15, 20 to-and-fro motion Visual assessment as stoping rule: 20 to-and-fro motion at different site will be performed when EUS-FNA sampling with 10, 15, 20 to-and-fro motion is unsatisfactory.
Autres noms:
For this prospective single-blinded randomized trial, two 10cc syringes was prepared.
Two syringe was provided as same performance.
However, one syringe is falsely made as suction syringe (fake one).
During EUS-FNA, two syringe is randomly assigned and loaded by a nurse.
Thus, operator was blinded which syringe is with suction or without suction.
Autres noms:
|
Que mesure l'étude ?
Principaux critères de jugement
Mesure des résultats |
Description de la mesure |
Délai |
|---|---|---|
|
Diagnostic accuracy
Délai: 1 year
|
The diagnostic accuracy of pancreatic masses at each sample according to EUS-FNA with suction or without suction/ different number of to-and-fro motion will be measured. Diagnostic accuracy of EUS-FNA with suction and 10, 15, and 20 to-and-fro motion vs.Diagnostic accuracy of EUS-FNA without suction and 10, 15, and 20 to-and-fro motion. |
1 year
|
Mesures de résultats secondaires
Mesure des résultats |
Description de la mesure |
Délai |
|---|---|---|
|
Blood contamination in each sample
Délai: 1 year
|
The amount of blood contamination at each sample according to EUS-FNA with suction or without suction/ different number of to-and-fro motion will be measured. The amount of blood contamination of EUS-FNA with suction and 10, 15, and 20 to-and-fro motion vs. The amount of blood contamination of EUS-FNA without suction and 10, 15, and 20 to-and-fro motion. |
1 year
|
Collaborateurs et enquêteurs
Parrainer
Les enquêteurs
- Chercheur principal: Do Hyun Park, MD, PhD, Asan Medical Center
Dates d'enregistrement des études
Dates principales de l'étude
Début de l'étude
Achèvement primaire (Réel)
Achèvement de l'étude (Réel)
Dates d'inscription aux études
Première soumission
Première soumission répondant aux critères de contrôle qualité
Première publication (Estimation)
Mises à jour des dossiers d'étude
Dernière mise à jour publiée (Estimation)
Dernière mise à jour soumise répondant aux critères de contrôle qualité
Dernière vérification
Plus d'information
Termes liés à cette étude
Mots clés
Autres numéros d'identification d'étude
- 2012-0018
Ces informations ont été extraites directement du site Web clinicaltrials.gov sans aucune modification. Si vous avez des demandes de modification, de suppression ou de mise à jour des détails de votre étude, veuillez contacter register@clinicaltrials.gov. Dès qu'un changement est mis en œuvre sur clinicaltrials.gov, il sera également mis à jour automatiquement sur notre site Web .