此页面是自动翻译的,不保证翻译的准确性。请参阅 英文版 对于源文本。

The Feasibility of Florbetapir Quantitation

2015年6月1日 更新者:Avid Radiopharmaceuticals

The Feasibility and Reliability of Utilizing Commercially Available Quantitative Analysis Software as an Adjunct to the Clinical Qualitative Interpretation of Amyvid Brain Scans

The overall objective of the study is to assess the feasibility of implementing a quantitative process of florbetapir F 18 scan interpretation. The hypothesis is that the use of quantitative analysis will increase the accuracy of florbetapir F 18 scan interpretation.

研究概览

地位

完全的

研究类型

介入性

注册 (实际的)

96

阶段

  • 第四阶段

联系人和位置

本节提供了进行研究的人员的详细联系信息,以及有关进行该研究的地点的信息。

学习地点

    • Pennsylvania
      • Philadelphia、Pennsylvania、美国、19103
        • Research Site

参与标准

研究人员寻找符合特定描述的人,称为资格标准。这些标准的一些例子是一个人的一般健康状况或先前的治疗。

资格标准

适合学习的年龄

  • 孩子
  • 成人
  • 年长者

接受健康志愿者

不

有资格学习的性别

全部

描述

Inclusion Criteria:

  • Readers have undergone Amyvid reader training
  • Readers have minimal experience with quantitation of amyloid PET scans

Exclusion Criteria:

  • Readers have previously been trained to quantitate amyloid PET scans

学习计划

本节提供研究计划的详细信息,包括研究的设计方式和研究的衡量标准。

研究是如何设计的?

设计细节

  • 主要用途:诊断
  • 分配:不适用
  • 介入模型:单组作业
  • 屏蔽:单身的

武器和干预

参与者组/臂
干预/治疗
实验性的:Physician Readers
Physician readers will interpret Amyvid scans using qualitative analysis followed by the use of quantitation. No subjects will be exposed to Florbetapir F 18 as part of this study.
No Florbetapir F 18 will be administered in this study.
其他名称:
  • 艾米维
  • 18F-AV-45
  • florbetapir

研究衡量的是什么?

主要结果指标

结果测量
措施说明
大体时间
Change in Total Accuracy (MIMNeuro Software, Low Accuracy Readers)
大体时间:Scan acquired 50-60 min post-injection
Evaluate whether the addition of quantitation as an adjunct to qualitative interpretations (VisQ) significantly improved the total accuracy of Amyvid scan interpretation in lower accuracy readers. Only the 46 scans with autopsy from A07/A16 are used for this outcome measure.
Scan acquired 50-60 min post-injection
Change in Total Accuracy (Siemens Syngo.PET Software, Experimental Arm Low Accuracy Readers)
大体时间:Scan acquired 50-60 min post-injection
Evaluate whether the addition of quantitation as an adjunct to qualitative interpretations (VisQ) significantly improved the total accuracy of Amyvid scan interpretation in lower accuracy readers. Only the 46 scans with autopsy from A07/A16 are used for this outcome measure.
Scan acquired 50-60 min post-injection

次要结果测量

结果测量
措施说明
大体时间
Change in Total Accuracy (MIMNeuro Software, All Readers)
大体时间:Scan acquired 50-60 min post-injection
Evaluate whether the total accuracy of Amyvid VisQ interpretation was non-inferior to the qualitative scan interpretation alone. Only the 46 scans with autopsy from A07/A16 are used for this outcome measure.
Scan acquired 50-60 min post-injection
Change in Reliability (MIMNeuro Software)
大体时间:Scan acquired 50-60 min post-injection
Evaluate whether VisQ interpretation significantly improved the reliability of Amyvid scan interpretation compared with qualitative scan interpretation alone. The scan interpretation reliability will be evaluated using Fleiss' Kappa statistics.
Scan acquired 50-60 min post-injection
Change in Total Accuracy (Siemens Syngo.PET Software, Experimental Arm All Readers)
大体时间:Scan acquired 50-60 min post-injection
Evaluate whether the total accuracy of Amyvid VisQ interpretation was non-inferior to the qualitative scan interpretation alone. Only the 46 scans with autopsy from A07/A16 are used for this outcome measure.
Scan acquired 50-60 min post-injection
Change in Reliability (Siemens Syngo.PET Software)
大体时间:Scan acquired 50-60 min post-injection
Evaluate whether VisQ interpretation significantly improved the reliability of Amyvid scan interpretation compared with qualitative scan interpretations alone. The scan interpretation reliability will be evaluated using Fleiss' Kappa statistics.
Scan acquired 50-60 min post-injection

合作者和调查者

在这里您可以找到参与这项研究的人员和组织。

研究记录日期

这些日期跟踪向 ClinicalTrials.gov 提交研究记录和摘要结果的进度。研究记录和报告的结果由国家医学图书馆 (NLM) 审查,以确保它们在发布到公共网站之前符合特定的质量控制标准。

研究主要日期

学习开始

2013年8月1日

初级完成 (实际的)

2014年4月1日

研究完成 (实际的)

2014年4月1日

研究注册日期

首次提交

2013年9月17日

首先提交符合 QC 标准的

2013年9月18日

首次发布 (估计)

2013年9月19日

研究记录更新

最后更新发布 (估计)

2015年6月29日

上次提交的符合 QC 标准的更新

2015年6月1日

最后验证

2015年6月1日

更多信息

与本研究相关的术语

此信息直接从 clinicaltrials.gov 网站检索,没有任何更改。如果您有任何更改、删除或更新研究详细信息的请求,请联系 register@clinicaltrials.gov. clinicaltrials.gov 上实施更改,我们的网站上也会自动更新.

订阅