Deze pagina is automatisch vertaald en de nauwkeurigheid van de vertaling kan niet worden gegarandeerd. Raadpleeg de Engelse versie voor een brontekst.

The Feasibility of Florbetapir Quantitation

1 juni 2015 bijgewerkt door: Avid Radiopharmaceuticals

The Feasibility and Reliability of Utilizing Commercially Available Quantitative Analysis Software as an Adjunct to the Clinical Qualitative Interpretation of Amyvid Brain Scans

The overall objective of the study is to assess the feasibility of implementing a quantitative process of florbetapir F 18 scan interpretation. The hypothesis is that the use of quantitative analysis will increase the accuracy of florbetapir F 18 scan interpretation.

Studie Overzicht

Toestand

Voltooid

Interventie / Behandeling

Studietype

Ingrijpend

Inschrijving (Werkelijk)

96

Fase

  • Fase 4

Contacten en locaties

In dit gedeelte vindt u de contactgegevens van degenen die het onderzoek uitvoeren en informatie over waar dit onderzoek wordt uitgevoerd.

Studie Locaties

    • Pennsylvania
      • Philadelphia, Pennsylvania, Verenigde Staten, 19103
        • Research Site

Deelname Criteria

Onderzoekers zoeken naar mensen die aan een bepaalde beschrijving voldoen, de zogenaamde geschiktheidscriteria. Enkele voorbeelden van deze criteria zijn iemands algemene gezondheidstoestand of eerdere behandelingen.

Geschiktheidscriteria

Leeftijden die in aanmerking komen voor studie

  • Kind
  • Volwassen
  • Oudere volwassene

Accepteert gezonde vrijwilligers

Nee

Geslachten die in aanmerking komen voor studie

Allemaal

Beschrijving

Inclusion Criteria:

  • Readers have undergone Amyvid reader training
  • Readers have minimal experience with quantitation of amyloid PET scans

Exclusion Criteria:

  • Readers have previously been trained to quantitate amyloid PET scans

Studie plan

Dit gedeelte bevat details van het studieplan, inclusief hoe de studie is opgezet en wat de studie meet.

Hoe is de studie opgezet?

Ontwerpdetails

  • Primair doel: Diagnostisch
  • Toewijzing: NVT
  • Interventioneel model: Opdracht voor een enkele groep
  • Masker: Enkel

Wapens en interventies

Deelnemersgroep / Arm
Interventie / Behandeling
Experimenteel: Physician Readers
Physician readers will interpret Amyvid scans using qualitative analysis followed by the use of quantitation. No subjects will be exposed to Florbetapir F 18 as part of this study.
No Florbetapir F 18 will be administered in this study.
Andere namen:
  • Amyvid
  • 18F-AV-45
  • florbetapir

Wat meet het onderzoek?

Primaire uitkomstmaten

Uitkomstmaat
Maatregel Beschrijving
Tijdsspanne
Change in Total Accuracy (MIMNeuro Software, Low Accuracy Readers)
Tijdsspanne: Scan acquired 50-60 min post-injection
Evaluate whether the addition of quantitation as an adjunct to qualitative interpretations (VisQ) significantly improved the total accuracy of Amyvid scan interpretation in lower accuracy readers. Only the 46 scans with autopsy from A07/A16 are used for this outcome measure.
Scan acquired 50-60 min post-injection
Change in Total Accuracy (Siemens Syngo.PET Software, Experimental Arm Low Accuracy Readers)
Tijdsspanne: Scan acquired 50-60 min post-injection
Evaluate whether the addition of quantitation as an adjunct to qualitative interpretations (VisQ) significantly improved the total accuracy of Amyvid scan interpretation in lower accuracy readers. Only the 46 scans with autopsy from A07/A16 are used for this outcome measure.
Scan acquired 50-60 min post-injection

Secundaire uitkomstmaten

Uitkomstmaat
Maatregel Beschrijving
Tijdsspanne
Change in Total Accuracy (MIMNeuro Software, All Readers)
Tijdsspanne: Scan acquired 50-60 min post-injection
Evaluate whether the total accuracy of Amyvid VisQ interpretation was non-inferior to the qualitative scan interpretation alone. Only the 46 scans with autopsy from A07/A16 are used for this outcome measure.
Scan acquired 50-60 min post-injection
Change in Reliability (MIMNeuro Software)
Tijdsspanne: Scan acquired 50-60 min post-injection
Evaluate whether VisQ interpretation significantly improved the reliability of Amyvid scan interpretation compared with qualitative scan interpretation alone. The scan interpretation reliability will be evaluated using Fleiss' Kappa statistics.
Scan acquired 50-60 min post-injection
Change in Total Accuracy (Siemens Syngo.PET Software, Experimental Arm All Readers)
Tijdsspanne: Scan acquired 50-60 min post-injection
Evaluate whether the total accuracy of Amyvid VisQ interpretation was non-inferior to the qualitative scan interpretation alone. Only the 46 scans with autopsy from A07/A16 are used for this outcome measure.
Scan acquired 50-60 min post-injection
Change in Reliability (Siemens Syngo.PET Software)
Tijdsspanne: Scan acquired 50-60 min post-injection
Evaluate whether VisQ interpretation significantly improved the reliability of Amyvid scan interpretation compared with qualitative scan interpretations alone. The scan interpretation reliability will be evaluated using Fleiss' Kappa statistics.
Scan acquired 50-60 min post-injection

Medewerkers en onderzoekers

Hier vindt u mensen en organisaties die betrokken zijn bij dit onderzoek.

Studie record data

Deze datums volgen de voortgang van het onderzoeksdossier en de samenvatting van de ingediende resultaten bij ClinicalTrials.gov. Studieverslagen en gerapporteerde resultaten worden beoordeeld door de National Library of Medicine (NLM) om er zeker van te zijn dat ze voldoen aan specifieke kwaliteitscontrolenormen voordat ze op de openbare website worden geplaatst.

Bestudeer belangrijke data

Studie start

1 augustus 2013

Primaire voltooiing (Werkelijk)

1 april 2014

Studie voltooiing (Werkelijk)

1 april 2014

Studieregistratiedata

Eerst ingediend

17 september 2013

Eerst ingediend dat voldeed aan de QC-criteria

18 september 2013

Eerst geplaatst (Schatting)

19 september 2013

Updates van studierecords

Laatste update geplaatst (Schatting)

29 juni 2015

Laatste update ingediend die voldeed aan QC-criteria

1 juni 2015

Laatst geverifieerd

1 juni 2015

Meer informatie

Deze informatie is zonder wijzigingen rechtstreeks van de website clinicaltrials.gov gehaald. Als u verzoeken heeft om uw onderzoeksgegevens te wijzigen, te verwijderen of bij te werken, neem dan contact op met register@clinicaltrials.gov. Zodra er een wijziging wordt doorgevoerd op clinicaltrials.gov, wordt deze ook automatisch bijgewerkt op onze website .

Abonneren