Physiological Behavior of Respiratory Maneuvers

2018年5月1日 更新者:Cláudia Thais Pereira Pinto、Universidade Federal de Pernambuco

Physiological Behavior of Respiratory Maneuvers Through Electrical Impedance Tomography and Optoelectronic Plethymography

Introduction: new methods of evaluation of respiratory function, such as electrical impedance tomography (EIT) and optoelectronic plethysmography (OEP), have been used to measure regional pulmonary ventilation and the variation of tricompartmental volumes of the thoracic cavity, respectively. Analysis of these instruments during maximal respiratory maneuvers with monitoring of esophageal pressure may probably provide additional information on the physiological behavior of the cardiorespiratory system during EIT and OEP maneuvers. Objectives: To describe the physiological behavior of maximal respiratory maneuvers through the electrical impedance tomography and optoelectronic plethysmography in healthy men.

METHODS: This is a cross-sectional study involving 10 healthy male volunteers. The development of the method will take place in 3 stages. The first step corresponds to the characterization of the inspiratory and expiratory curves in the respiratory cycle generated by the impedance variation (ΔZ), the mobility of the chest wall and the pulmonary volume curve during maximal respiratory maneuvers. 2nd stage: verification of the correlation between the variables Step 3: Estimate the dislocated blood volume of the lung through previous analyzes.

研究概览

地位

完全的

详细说明

The physiological repercussions resulting from the maximal respiratory maneuvers together with the synchronized analysis of the chest cavity mobility, pulmonary volume , pulmonary impedance and measurement of Oesophageal pressure is not known. Therefore, this study aims to describe the physiological behavior of maximal respiratory maneuvers through the synchronization between electrical impedance tomography and optoelectronic plethysmography in healthy men.

研究类型

观察性的

注册 (实际的)

10

联系人和位置

本节提供了进行研究的人员的详细联系信息,以及有关进行该研究的地点的信息。

学习地点

    • PE - Pernambuco
      • Recife、PE - Pernambuco、巴西、50740300
        • Universidade Federal de Pernambuco

参与标准

研究人员寻找符合特定描述的人,称为资格标准。这些标准的一些例子是一个人的一般健康状况或先前的治疗。

资格标准

适合学习的年龄

18年 至 35年 (成人)

接受健康志愿者

有资格学习的性别

男性

取样方法

非概率样本

研究人群

The study sample will be composed of healthy male volunteers.

描述

Inclusion Criteria:

  • Will be included in the study male volunteers,
  • BMI greater than or equal to 18.5 and less than 25 kg / m2, considered adequate or eutrophic (MS, 2011)
  • Chest circumference between 44 and 55 cm if fitted to the electrical impedance tomography (EIT) strap size P or M;
  • systolic blood pressure lower than 140 mmHg and greater than 100 mmHg
  • diastolic blood pressure greater than 60 mmHg and lower than 90 mmHg (VI Brazilian Guidelines for Hypertension, 2010)
  • without reports of cardiovascular or pulmonary diseases and symptoms Last month.

Exclusion Criteria:

  • Volunteers who refuse to participate in the study will be excluded from the survey;
  • Presence of cardiac dysfunction assessed by echocardiography;
  • Altered pulmonary function by spirometry (PEREIRA et al, 2001) and manovacuometry according to predicted values for healthy individuals (PESSOA et al, 2014).
  • Presence of tissue injury in the thorax;
  • Dysautonomia that may indicate dysfunction of the autonomic nervous system (ANS), with following clinical manifestations: seizures; epilepsy; Anhydrosis and hyperhidrosis; Neurogenic bladder (CASTRO et al, 1992); (Stewart et al., 2004 and 2005)
  • individuals who donated blood or had significant blood loss within 30 days prior to the start of the study (Navarro et al, 1997).

学习计划

本节提供研究计划的详细信息,包括研究的设计方式和研究的衡量标准。

研究是如何设计的?

设计细节

  • 观测模型:其他
  • 时间观点:横截面

研究衡量的是什么?

主要结果指标

结果测量
措施说明
大体时间
Displacement of blood volume of the lung
大体时间:09/03/2018
Volume displacement per unit time measured by electrical impedance tomography through the impedance variation in Ohm (Ω).
09/03/2018

次要结果测量

结果测量
措施说明
大体时间
Variation of pulmonary electrical impedance
大体时间:09/03/2018
Variation between the final and initial impedance measured by electrical impedance tomography through the impedance variation in Ohm (Ω).
09/03/2018

其他结果措施

结果测量
措施说明
大体时间
Lung volume
大体时间:09/03/2018
Measurement of the amount of air that the lungs may contain at various points in the respiratory cycle.
09/03/2018

合作者和调查者

在这里您可以找到参与这项研究的人员和组织。

调查人员

  • 首席研究员:Cláudia Thais Pinto, Ms、UFPE

研究记录日期

这些日期跟踪向 ClinicalTrials.gov 提交研究记录和摘要结果的进度。研究记录和报告的结果由国家医学图书馆 (NLM) 审查,以确保它们在发布到公共网站之前符合特定的质量控制标准。

研究主要日期

学习开始 (实际的)

2017年4月7日

初级完成 (实际的)

2018年2月20日

研究完成 (实际的)

2018年3月23日

研究注册日期

首次提交

2017年6月16日

首先提交符合 QC 标准的

2017年8月30日

首次发布 (实际的)

2017年9月1日

研究记录更新

最后更新发布 (实际的)

2018年5月4日

上次提交的符合 QC 标准的更新

2018年5月1日

最后验证

2018年5月1日

更多信息

与本研究相关的术语

其他研究编号

  • 23031990

计划个人参与者数据 (IPD)

计划共享个人参与者数据 (IPD)?

药物和器械信息、研究文件

研究美国 FDA 监管的药品

研究美国 FDA 监管的设备产品

此信息直接从 clinicaltrials.gov 网站检索,没有任何更改。如果您有任何更改、删除或更新研究详细信息的请求,请联系 register@clinicaltrials.gov. clinicaltrials.gov 上实施更改,我们的网站上也会自动更新.

3
订阅