- ICH GCP
- Register voor klinische proeven in de VS.
- Klinische proef NCT03270826
Physiological Behavior of Respiratory Maneuvers
Physiological Behavior of Respiratory Maneuvers Through Electrical Impedance Tomography and Optoelectronic Plethymography
Introduction: new methods of evaluation of respiratory function, such as electrical impedance tomography (EIT) and optoelectronic plethysmography (OEP), have been used to measure regional pulmonary ventilation and the variation of tricompartmental volumes of the thoracic cavity, respectively. Analysis of these instruments during maximal respiratory maneuvers with monitoring of esophageal pressure may probably provide additional information on the physiological behavior of the cardiorespiratory system during EIT and OEP maneuvers. Objectives: To describe the physiological behavior of maximal respiratory maneuvers through the electrical impedance tomography and optoelectronic plethysmography in healthy men.
METHODS: This is a cross-sectional study involving 10 healthy male volunteers. The development of the method will take place in 3 stages. The first step corresponds to the characterization of the inspiratory and expiratory curves in the respiratory cycle generated by the impedance variation (ΔZ), the mobility of the chest wall and the pulmonary volume curve during maximal respiratory maneuvers. 2nd stage: verification of the correlation between the variables Step 3: Estimate the dislocated blood volume of the lung through previous analyzes.
Studie Overzicht
Toestand
Conditie
Gedetailleerde beschrijving
Studietype
Inschrijving (Werkelijk)
Contacten en locaties
Studie Locaties
-
-
PE - Pernambuco
-
Recife, PE - Pernambuco, Brazilië, 50740300
- Universidade Federal de Pernambuco
-
-
Deelname Criteria
Geschiktheidscriteria
Leeftijden die in aanmerking komen voor studie
Accepteert gezonde vrijwilligers
Geslachten die in aanmerking komen voor studie
Bemonsteringsmethode
Studie Bevolking
Beschrijving
Inclusion Criteria:
- Will be included in the study male volunteers,
- BMI greater than or equal to 18.5 and less than 25 kg / m2, considered adequate or eutrophic (MS, 2011)
- Chest circumference between 44 and 55 cm if fitted to the electrical impedance tomography (EIT) strap size P or M;
- systolic blood pressure lower than 140 mmHg and greater than 100 mmHg
- diastolic blood pressure greater than 60 mmHg and lower than 90 mmHg (VI Brazilian Guidelines for Hypertension, 2010)
- without reports of cardiovascular or pulmonary diseases and symptoms Last month.
Exclusion Criteria:
- Volunteers who refuse to participate in the study will be excluded from the survey;
- Presence of cardiac dysfunction assessed by echocardiography;
- Altered pulmonary function by spirometry (PEREIRA et al, 2001) and manovacuometry according to predicted values for healthy individuals (PESSOA et al, 2014).
- Presence of tissue injury in the thorax;
- Dysautonomia that may indicate dysfunction of the autonomic nervous system (ANS), with following clinical manifestations: seizures; epilepsy; Anhydrosis and hyperhidrosis; Neurogenic bladder (CASTRO et al, 1992); (Stewart et al., 2004 and 2005)
- individuals who donated blood or had significant blood loss within 30 days prior to the start of the study (Navarro et al, 1997).
Studie plan
Hoe is de studie opgezet?
Ontwerpdetails
- Observatiemodellen: Ander
- Tijdsperspectieven: Dwarsdoorsnede
Wat meet het onderzoek?
Primaire uitkomstmaten
Uitkomstmaat |
Maatregel Beschrijving |
Tijdsspanne |
---|---|---|
Displacement of blood volume of the lung
Tijdsspanne: 09/03/2018
|
Volume displacement per unit time measured by electrical impedance tomography through the impedance variation in Ohm (Ω).
|
09/03/2018
|
Secundaire uitkomstmaten
Uitkomstmaat |
Maatregel Beschrijving |
Tijdsspanne |
---|---|---|
Variation of pulmonary electrical impedance
Tijdsspanne: 09/03/2018
|
Variation between the final and initial impedance measured by electrical impedance tomography through the impedance variation in Ohm (Ω).
|
09/03/2018
|
Andere uitkomstmaten
Uitkomstmaat |
Maatregel Beschrijving |
Tijdsspanne |
---|---|---|
Lung volume
Tijdsspanne: 09/03/2018
|
Measurement of the amount of air that the lungs may contain at various points in the respiratory cycle.
|
09/03/2018
|
Medewerkers en onderzoekers
Onderzoekers
- Hoofdonderzoeker: Cláudia Thais Pinto, Ms, UFPE
Studie record data
Bestudeer belangrijke data
Studie start (Werkelijk)
Primaire voltooiing (Werkelijk)
Studie voltooiing (Werkelijk)
Studieregistratiedata
Eerst ingediend
Eerst ingediend dat voldeed aan de QC-criteria
Eerst geplaatst (Werkelijk)
Updates van studierecords
Laatste update geplaatst (Werkelijk)
Laatste update ingediend die voldeed aan QC-criteria
Laatst geverifieerd
Meer informatie
Termen gerelateerd aan deze studie
Andere studie-ID-nummers
- 23031990
Plan Individuele Deelnemersgegevens (IPD)
Bent u van plan om gegevens van individuele deelnemers (IPD) te delen?
Informatie over medicijnen en apparaten, studiedocumenten
Bestudeert een door de Amerikaanse FDA gereguleerd geneesmiddel
Bestudeert een door de Amerikaanse FDA gereguleerd apparaatproduct
Deze informatie is zonder wijzigingen rechtstreeks van de website clinicaltrials.gov gehaald. Als u verzoeken heeft om uw onderzoeksgegevens te wijzigen, te verwijderen of bij te werken, neem dan contact op met register@clinicaltrials.gov. Zodra er een wijziging wordt doorgevoerd op clinicaltrials.gov, wordt deze ook automatisch bijgewerkt op onze website .
Klinische onderzoeken op Gezonde vrijwilligers
-
University of LeicesterNational Institute for Health Research, United KingdomVoltooidPatiënten met hartfalen en behouden ejectiefractie - HFpEF | Patiënten met hartfalen met verminderde ejectiefractie - HFrEF | Healthy Controls Group - Leeftijd en geslacht afgestemd
-
University Hospital, GrenobleUniversity Hospital, Clermont-Ferrand; Grenoble Institut des NeurosciencesBeëindigdZiekte van Parkinson | Healthy Controls Group - Leeftijd en geslacht afgestemdFrankrijk