Spirometry Using Electrical Impedance Tomography (EIT)
Realization of Spirometry Measurement Using Electrical Impedance Tomography (EIT)
The main aim of this study is to test spirometry measurements using EIT with a calibration using tidal volume obtained from the simultaneous standard spirometry measurement. Another goal is to compare, based on the calibration, the spirometry parameters obtained from separate measurements using EIT and the standard spirometry using a pneumotachograph.
All spirometry measurements will be conducted in accordance with the latest available standards of the American Thoracic Society (ATS) and European Respiratory Society (ERS) from the year 2005, including their emendation from 2017.
研究概览
地位
条件
详细说明
研究类型
注册 (实际的)
阶段
- 不适用
联系人和位置
学习地点
-
-
Czech Republic
-
Kladno、Czech Republic、捷克语、272 01
- Department of Biomedical Technology Faculty of Biomedical Engineering Czech Technical University in Prague
-
-
参与标准
资格标准
适合学习的年龄
接受健康志愿者
有资格学习的性别
描述
Inclusion Criteria:
- Healthy males and females > 18 years old
- Signed informed consent has been obtained
Exclusion Criteria:
- Pregnancy
- Cardiac pacemakers
- Electrically active implant
- Critical illness
- Intrathoracic metal implants
- Value of body mass index (BMI)>50
学习计划
研究是如何设计的?
设计细节
- 主要用途:支持治疗
- 分配:随机化
- 介入模型:并行分配
- 屏蔽:无(打开标签)
武器和干预
参与者组/臂 |
干预/治疗 |
|---|---|
|
无干预:Standard spirometry
Standard spirometry measurement with a pneumotachograph alone.
|
|
|
实验性的:EIT alone
Spirometric examinations realized using the EIT
|
Spirometric examinations will be realized using the EIT alone.
|
|
实验性的:Simultaneous standard spirometry and EIT
Simultaneous measurement by spirometer and EIT
|
Spirometric examinations will be realized using the simultaneous measurement by spirometer and EIT
|
研究衡量的是什么?
主要结果指标
结果测量 |
措施说明 |
大体时间 |
|---|---|---|
|
FVC
大体时间:through study completion, an average of 1 year
|
forced vital capacity (L)
|
through study completion, an average of 1 year
|
|
FEV1
大体时间:through study completion, an average of 1 year
|
forced expiratory volume exhaled in the first second of a forced expiration (L)
|
through study completion, an average of 1 year
|
|
TI
大体时间:through study completion, an average of 1 year
|
ratio of FEV1/FVC called Tiffeneau index (-)
|
through study completion, an average of 1 year
|
合作者和调查者
调查人员
- 首席研究员:Karel Roubík, prof.、Czech Technical University in Prague, FBMI
出版物和有用的链接
一般刊物
- Ngo C, Leonhardt S, Zhang T, Luken M, Misgeld B, Vollmer T, Tenbrock K, Lehmann S. Linearity of electrical impedance tomography during maximum effort breathing and forced expiration maneuvers. Physiol Meas. 2017 Jan;38(1):77-86. doi: 10.1088/1361-6579/38/1/77. Epub 2016 Dec 22.
- Vogt B, Lohr S, Zhao Z, Falkenberg C, Ankermann T, Weiler N, Frerichs I. Regional lung function testing in children using electrical impedance tomography. Pediatr Pulmonol. 2018 Mar;53(3):293-301. doi: 10.1002/ppul.23912. Epub 2017 Nov 14.
- Lehmann S, Leonhardt S, Ngo C, Bergmann L, Ayed I, Schrading S, Tenbrock K. Global and regional lung function in cystic fibrosis measured by electrical impedance tomography. Pediatr Pulmonol. 2016 Nov;51(11):1191-1199. doi: 10.1002/ppul.23444. Epub 2016 Apr 29.
- Vogt B, Zhao Z, Zabel P, Weiler N, Frerichs I. Regional lung response to bronchodilator reversibility testing determined by electrical impedance tomography in chronic obstructive pulmonary disease. Am J Physiol Lung Cell Mol Physiol. 2016 Jul 1;311(1):L8-L19. doi: 10.1152/ajplung.00463.2015. Epub 2016 May 17.
研究记录日期
研究主要日期
学习开始 (实际的)
初级完成 (实际的)
研究完成 (实际的)
研究注册日期
首次提交
首先提交符合 QC 标准的
首次发布 (实际的)
研究记录更新
最后更新发布 (实际的)
上次提交的符合 QC 标准的更新
最后验证
更多信息
与本研究相关的术语
其他研究编号
- EITspiro
计划个人参与者数据 (IPD)
计划共享个人参与者数据 (IPD)?
IPD 计划说明
药物和器械信息、研究文件
研究美国 FDA 监管的药品
研究美国 FDA 监管的设备产品