- ICH GCP
- Registro de ensaios clínicos dos EUA
- Ensaio Clínico NCT03746795
Spirometry Using Electrical Impedance Tomography (EIT)
Realization of Spirometry Measurement Using Electrical Impedance Tomography (EIT)
The main aim of this study is to test spirometry measurements using EIT with a calibration using tidal volume obtained from the simultaneous standard spirometry measurement. Another goal is to compare, based on the calibration, the spirometry parameters obtained from separate measurements using EIT and the standard spirometry using a pneumotachograph.
All spirometry measurements will be conducted in accordance with the latest available standards of the American Thoracic Society (ATS) and European Respiratory Society (ERS) from the year 2005, including their emendation from 2017.
Visão geral do estudo
Status
Condições
Descrição detalhada
Tipo de estudo
Inscrição (Real)
Estágio
- Não aplicável
Contactos e Locais
Locais de estudo
-
-
Czech Republic
-
Kladno, Czech Republic, Tcheca, 272 01
- Department of Biomedical Technology Faculty of Biomedical Engineering Czech Technical University in Prague
-
-
Critérios de participação
Critérios de elegibilidade
Idades elegíveis para estudo
Aceita Voluntários Saudáveis
Gêneros Elegíveis para o Estudo
Descrição
Inclusion Criteria:
- Healthy males and females > 18 years old
- Signed informed consent has been obtained
Exclusion Criteria:
- Pregnancy
- Cardiac pacemakers
- Electrically active implant
- Critical illness
- Intrathoracic metal implants
- Value of body mass index (BMI)>50
Plano de estudo
Como o estudo é projetado?
Detalhes do projeto
- Finalidade Principal: Cuidados de suporte
- Alocação: Randomizado
- Modelo Intervencional: Atribuição Paralela
- Mascaramento: Nenhum (rótulo aberto)
Armas e Intervenções
Grupo de Participantes / Braço |
Intervenção / Tratamento |
---|---|
Sem intervenção: Standard spirometry
Standard spirometry measurement with a pneumotachograph alone.
|
|
Experimental: EIT alone
Spirometric examinations realized using the EIT
|
Spirometric examinations will be realized using the EIT alone.
|
Experimental: Simultaneous standard spirometry and EIT
Simultaneous measurement by spirometer and EIT
|
Spirometric examinations will be realized using the simultaneous measurement by spirometer and EIT
|
O que o estudo está medindo?
Medidas de resultados primários
Medida de resultado |
Descrição da medida |
Prazo |
---|---|---|
FVC
Prazo: through study completion, an average of 1 year
|
forced vital capacity (L)
|
through study completion, an average of 1 year
|
FEV1
Prazo: through study completion, an average of 1 year
|
forced expiratory volume exhaled in the first second of a forced expiration (L)
|
through study completion, an average of 1 year
|
TI
Prazo: through study completion, an average of 1 year
|
ratio of FEV1/FVC called Tiffeneau index (-)
|
through study completion, an average of 1 year
|
Colaboradores e Investigadores
Patrocinador
Investigadores
- Investigador principal: Karel Roubík, prof., Czech Technical University in Prague, FBMI
Publicações e links úteis
Publicações Gerais
- Ngo C, Leonhardt S, Zhang T, Luken M, Misgeld B, Vollmer T, Tenbrock K, Lehmann S. Linearity of electrical impedance tomography during maximum effort breathing and forced expiration maneuvers. Physiol Meas. 2017 Jan;38(1):77-86. doi: 10.1088/1361-6579/38/1/77. Epub 2016 Dec 22.
- Vogt B, Lohr S, Zhao Z, Falkenberg C, Ankermann T, Weiler N, Frerichs I. Regional lung function testing in children using electrical impedance tomography. Pediatr Pulmonol. 2018 Mar;53(3):293-301. doi: 10.1002/ppul.23912. Epub 2017 Nov 14.
- Lehmann S, Leonhardt S, Ngo C, Bergmann L, Ayed I, Schrading S, Tenbrock K. Global and regional lung function in cystic fibrosis measured by electrical impedance tomography. Pediatr Pulmonol. 2016 Nov;51(11):1191-1199. doi: 10.1002/ppul.23444. Epub 2016 Apr 29.
- Vogt B, Zhao Z, Zabel P, Weiler N, Frerichs I. Regional lung response to bronchodilator reversibility testing determined by electrical impedance tomography in chronic obstructive pulmonary disease. Am J Physiol Lung Cell Mol Physiol. 2016 Jul 1;311(1):L8-L19. doi: 10.1152/ajplung.00463.2015. Epub 2016 May 17.
Datas de registro do estudo
Datas Principais do Estudo
Início do estudo (Real)
Conclusão Primária (Real)
Conclusão do estudo (Real)
Datas de inscrição no estudo
Enviado pela primeira vez
Enviado pela primeira vez que atendeu aos critérios de CQ
Primeira postagem (Real)
Atualizações de registro de estudo
Última Atualização Postada (Real)
Última atualização enviada que atendeu aos critérios de controle de qualidade
Última verificação
Mais Informações
Termos relacionados a este estudo
Palavras-chave
Outros números de identificação do estudo
- EITspiro
Plano para dados de participantes individuais (IPD)
Planeja compartilhar dados de participantes individuais (IPD)?
Descrição do plano IPD
Informações sobre medicamentos e dispositivos, documentos de estudo
Estuda um medicamento regulamentado pela FDA dos EUA
Estuda um produto de dispositivo regulamentado pela FDA dos EUA
Essas informações foram obtidas diretamente do site clinicaltrials.gov sem nenhuma alteração. Se você tiver alguma solicitação para alterar, remover ou atualizar os detalhes do seu estudo, entre em contato com register@clinicaltrials.gov. Assim que uma alteração for implementada em clinicaltrials.gov, ela também será atualizada automaticamente em nosso site .