- ICH GCP
- 미국 임상 시험 레지스트리
- 임상시험 NCT03746795
Spirometry Using Electrical Impedance Tomography (EIT)
Realization of Spirometry Measurement Using Electrical Impedance Tomography (EIT)
The main aim of this study is to test spirometry measurements using EIT with a calibration using tidal volume obtained from the simultaneous standard spirometry measurement. Another goal is to compare, based on the calibration, the spirometry parameters obtained from separate measurements using EIT and the standard spirometry using a pneumotachograph.
All spirometry measurements will be conducted in accordance with the latest available standards of the American Thoracic Society (ATS) and European Respiratory Society (ERS) from the year 2005, including their emendation from 2017.
연구 개요
상태
정황
상세 설명
연구 유형
등록 (실제)
단계
- 해당 없음
연락처 및 위치
연구 장소
-
-
Czech Republic
-
Kladno, Czech Republic, 체코, 272 01
- Department of Biomedical Technology Faculty of Biomedical Engineering Czech Technical University in Prague
-
-
참여기준
자격 기준
공부할 수 있는 나이
건강한 자원 봉사자를 받아들입니다
연구 대상 성별
설명
Inclusion Criteria:
- Healthy males and females > 18 years old
- Signed informed consent has been obtained
Exclusion Criteria:
- Pregnancy
- Cardiac pacemakers
- Electrically active implant
- Critical illness
- Intrathoracic metal implants
- Value of body mass index (BMI)>50
공부 계획
연구는 어떻게 설계됩니까?
디자인 세부사항
- 주 목적: 지지 요법
- 할당: 무작위
- 중재 모델: 병렬 할당
- 마스킹: 없음(오픈 라벨)
무기와 개입
참가자 그룹 / 팔 |
개입 / 치료 |
---|---|
간섭 없음: Standard spirometry
Standard spirometry measurement with a pneumotachograph alone.
|
|
실험적: EIT alone
Spirometric examinations realized using the EIT
|
Spirometric examinations will be realized using the EIT alone.
|
실험적: Simultaneous standard spirometry and EIT
Simultaneous measurement by spirometer and EIT
|
Spirometric examinations will be realized using the simultaneous measurement by spirometer and EIT
|
연구는 무엇을 측정합니까?
주요 결과 측정
결과 측정 |
측정값 설명 |
기간 |
---|---|---|
FVC
기간: through study completion, an average of 1 year
|
forced vital capacity (L)
|
through study completion, an average of 1 year
|
FEV1
기간: through study completion, an average of 1 year
|
forced expiratory volume exhaled in the first second of a forced expiration (L)
|
through study completion, an average of 1 year
|
TI
기간: through study completion, an average of 1 year
|
ratio of FEV1/FVC called Tiffeneau index (-)
|
through study completion, an average of 1 year
|
공동 작업자 및 조사자
수사관
- 수석 연구원: Karel Roubík, prof., Czech Technical University in Prague, FBMI
간행물 및 유용한 링크
일반 간행물
- Ngo C, Leonhardt S, Zhang T, Luken M, Misgeld B, Vollmer T, Tenbrock K, Lehmann S. Linearity of electrical impedance tomography during maximum effort breathing and forced expiration maneuvers. Physiol Meas. 2017 Jan;38(1):77-86. doi: 10.1088/1361-6579/38/1/77. Epub 2016 Dec 22.
- Vogt B, Lohr S, Zhao Z, Falkenberg C, Ankermann T, Weiler N, Frerichs I. Regional lung function testing in children using electrical impedance tomography. Pediatr Pulmonol. 2018 Mar;53(3):293-301. doi: 10.1002/ppul.23912. Epub 2017 Nov 14.
- Lehmann S, Leonhardt S, Ngo C, Bergmann L, Ayed I, Schrading S, Tenbrock K. Global and regional lung function in cystic fibrosis measured by electrical impedance tomography. Pediatr Pulmonol. 2016 Nov;51(11):1191-1199. doi: 10.1002/ppul.23444. Epub 2016 Apr 29.
- Vogt B, Zhao Z, Zabel P, Weiler N, Frerichs I. Regional lung response to bronchodilator reversibility testing determined by electrical impedance tomography in chronic obstructive pulmonary disease. Am J Physiol Lung Cell Mol Physiol. 2016 Jul 1;311(1):L8-L19. doi: 10.1152/ajplung.00463.2015. Epub 2016 May 17.
연구 기록 날짜
연구 주요 날짜
연구 시작 (실제)
기본 완료 (실제)
연구 완료 (실제)
연구 등록 날짜
최초 제출
QC 기준을 충족하는 최초 제출
처음 게시됨 (실제)
연구 기록 업데이트
마지막 업데이트 게시됨 (실제)
QC 기준을 충족하는 마지막 업데이트 제출
마지막으로 확인됨
추가 정보
이 연구와 관련된 용어
기타 연구 ID 번호
- EITspiro
개별 참가자 데이터(IPD) 계획
개별 참가자 데이터(IPD)를 공유할 계획입니까?
IPD 계획 설명
약물 및 장치 정보, 연구 문서
미국 FDA 규제 의약품 연구
미국 FDA 규제 기기 제품 연구
이 정보는 변경 없이 clinicaltrials.gov 웹사이트에서 직접 가져온 것입니다. 귀하의 연구 세부 정보를 변경, 제거 또는 업데이트하도록 요청하는 경우 register@clinicaltrials.gov. 문의하십시오. 변경 사항이 clinicaltrials.gov에 구현되는 즉시 저희 웹사이트에도 자동으로 업데이트됩니다. .