Spirometry Using Electrical Impedance Tomography (EIT)
Realization of Spirometry Measurement Using Electrical Impedance Tomography (EIT)
The main aim of this study is to test spirometry measurements using EIT with a calibration using tidal volume obtained from the simultaneous standard spirometry measurement. Another goal is to compare, based on the calibration, the spirometry parameters obtained from separate measurements using EIT and the standard spirometry using a pneumotachograph.
All spirometry measurements will be conducted in accordance with the latest available standards of the American Thoracic Society (ATS) and European Respiratory Society (ERS) from the year 2005, including their emendation from 2017.
Tutkimuksen yleiskatsaus
Tila
Ehdot
Yksityiskohtainen kuvaus
Opintotyyppi
Ilmoittautuminen (Todellinen)
Vaihe
- Ei sovellettavissa
Yhteystiedot ja paikat
Opiskelupaikat
-
-
Czech Republic
-
Kladno, Czech Republic, Tšekki, 272 01
- Department of Biomedical Technology Faculty of Biomedical Engineering Czech Technical University in Prague
-
-
Osallistumiskriteerit
Kelpoisuusvaatimukset
Opintokelpoiset iät
Hyväksyy terveitä vapaaehtoisia
Sukupuolet, jotka voivat opiskella
Kuvaus
Inclusion Criteria:
- Healthy males and females > 18 years old
- Signed informed consent has been obtained
Exclusion Criteria:
- Pregnancy
- Cardiac pacemakers
- Electrically active implant
- Critical illness
- Intrathoracic metal implants
- Value of body mass index (BMI)>50
Opintosuunnitelma
Miten tutkimus on suunniteltu?
Suunnittelun yksityiskohdat
- Ensisijainen käyttötarkoitus: Tukevaa hoitoa
- Jako: Satunnaistettu
- Inventiomalli: Rinnakkaistehtävä
- Naamiointi: Ei mitään (avoin tarra)
Aseet ja interventiot
Osallistujaryhmä / Arm |
Interventio / Hoito |
|---|---|
|
Ei väliintuloa: Standard spirometry
Standard spirometry measurement with a pneumotachograph alone.
|
|
|
Kokeellinen: EIT alone
Spirometric examinations realized using the EIT
|
Spirometric examinations will be realized using the EIT alone.
|
|
Kokeellinen: Simultaneous standard spirometry and EIT
Simultaneous measurement by spirometer and EIT
|
Spirometric examinations will be realized using the simultaneous measurement by spirometer and EIT
|
Mitä tutkimuksessa mitataan?
Ensisijaiset tulostoimenpiteet
Tulosmittaus |
Toimenpiteen kuvaus |
Aikaikkuna |
|---|---|---|
|
FVC
Aikaikkuna: through study completion, an average of 1 year
|
forced vital capacity (L)
|
through study completion, an average of 1 year
|
|
FEV1
Aikaikkuna: through study completion, an average of 1 year
|
forced expiratory volume exhaled in the first second of a forced expiration (L)
|
through study completion, an average of 1 year
|
|
TI
Aikaikkuna: through study completion, an average of 1 year
|
ratio of FEV1/FVC called Tiffeneau index (-)
|
through study completion, an average of 1 year
|
Yhteistyökumppanit ja tutkijat
Sponsori
Tutkijat
- Päätutkija: Karel Roubík, prof., Czech Technical University in Prague, FBMI
Julkaisuja ja hyödyllisiä linkkejä
Yleiset julkaisut
- Ngo C, Leonhardt S, Zhang T, Luken M, Misgeld B, Vollmer T, Tenbrock K, Lehmann S. Linearity of electrical impedance tomography during maximum effort breathing and forced expiration maneuvers. Physiol Meas. 2017 Jan;38(1):77-86. doi: 10.1088/1361-6579/38/1/77. Epub 2016 Dec 22.
- Vogt B, Lohr S, Zhao Z, Falkenberg C, Ankermann T, Weiler N, Frerichs I. Regional lung function testing in children using electrical impedance tomography. Pediatr Pulmonol. 2018 Mar;53(3):293-301. doi: 10.1002/ppul.23912. Epub 2017 Nov 14.
- Lehmann S, Leonhardt S, Ngo C, Bergmann L, Ayed I, Schrading S, Tenbrock K. Global and regional lung function in cystic fibrosis measured by electrical impedance tomography. Pediatr Pulmonol. 2016 Nov;51(11):1191-1199. doi: 10.1002/ppul.23444. Epub 2016 Apr 29.
- Vogt B, Zhao Z, Zabel P, Weiler N, Frerichs I. Regional lung response to bronchodilator reversibility testing determined by electrical impedance tomography in chronic obstructive pulmonary disease. Am J Physiol Lung Cell Mol Physiol. 2016 Jul 1;311(1):L8-L19. doi: 10.1152/ajplung.00463.2015. Epub 2016 May 17.
Opintojen ennätyspäivät
Opi tärkeimmät päivämäärät
Opiskelun aloitus (Todellinen)
Ensisijainen valmistuminen (Todellinen)
Opintojen valmistuminen (Todellinen)
Opintoihin ilmoittautumispäivät
Ensimmäinen lähetetty
Ensimmäinen toimitettu, joka täytti QC-kriteerit
Ensimmäinen Lähetetty (Todellinen)
Tutkimustietojen päivitykset
Viimeisin päivitys julkaistu (Todellinen)
Viimeisin lähetetty päivitys, joka täytti QC-kriteerit
Viimeksi vahvistettu
Lisää tietoa
Tähän tutkimukseen liittyvät termit
Muut tutkimustunnusnumerot
- EITspiro
Yksittäisten osallistujien tietojen suunnitelma (IPD)
Aiotko jakaa yksittäisten osallistujien tietoja (IPD)?
IPD-suunnitelman kuvaus
Lääke- ja laitetiedot, tutkimusasiakirjat
Tutkii yhdysvaltalaista FDA sääntelemää lääkevalmistetta
Tutkii yhdysvaltalaista FDA sääntelemää laitetuotetta
Nämä tiedot haettiin suoraan verkkosivustolta clinicaltrials.gov ilman muutoksia. Jos sinulla on pyyntöjä muuttaa, poistaa tai päivittää tutkimustietojasi, ota yhteyttä register@clinicaltrials.gov. Heti kun muutos on otettu käyttöön osoitteessa clinicaltrials.gov, se päivitetään automaattisesti myös verkkosivustollemme .