Outcomes of High Power Application in Catheter Ablation of Paroxysmal Atrial Fibrillation Guided by Unipolar Signal Modification.
Pulmonary vein isolation (PVI) is the cornerstone of catheter ablation procedures in patients with paroxysmal atrial fibrillation (PAF) [1]. However, the incidence of atrial fibrillation (AF) recurrence remains high [2], mostly due to pulmonary vein (PV) reconnection [1], emphasizing the formation of transmural lesions to achieve complete conduction block along the ablation lines [3].
Previous studies have shown that elimination of the negative component of the unipolar electrogram (UP-EGM) during radiofrequency applications reflects transmural lesions. The persistence of such a negative component consistently corresponds to non-trans mural lesions [4].
研究概览
详细说明
Pulmonary vein isolation (PVI) is the cornerstone of catheter ablation procedures in patients with paroxysmal atrial fibrillation (PAF) [1]. However, the incidence of atrial fibrillation (AF) recurrence remains high [2], mostly due to pulmonary vein (PV) reconnection [1], emphasizing the formation of transmural lesions to achieve complete conduction block along the ablation lines [3].
Previous studies have shown that elimination of the negative component of the unipolar electrogram (UP-EGM) during radiofrequency applications reflects transmural lesions. The persistence of such a negative component consistently corresponds to non-trans mural lesions [4].
The high-power short duration (HPSD) RF application applies to all RF energies delivered at more than 40 W [5]. Higher the power more is the resistive heating causing wider tissue injury [5]. The lesion size with HPSD is larger in width but lesser in depth compared to lower powers with longer duration [5]. In contrast, RF applications of lower power and longer duration result in larger dissipation of RF energies deep into the tissues due to conductive heating causing tissue destruction at greater depths [6]. Hence, there is a risk of collateral tissue damage [5].
HPSD ablation has been advocated as a means to minimize the risk of collateral organ damage as the lesions are smaller in depth. However, Maintaining a high power for a constant duration in the absence of a guide may not be the right strategy [5].
Unipolar waveform modification by complete elimination of the negative component may serve as a guide for HPSD ablation [5].
研究类型
注册 (预期的)
阶段
- 不适用
参与标准
资格标准
适合学习的年龄
接受健康志愿者
有资格学习的性别
描述
Inclusion Criteria:
- Paroxysmal atrial fibrillation
Exclusion Criteria:
- Age< 18 or > 80 years old,
- Atrium (LA) diameter > 50 mm,
- The presence of a mechanical mitral valve prosthesis,
- Left ventricular ejection fraction < 40%,
- Abnormal thyroid function,
- Contraindication to anticoagulant therapy,
- Current malignancy,
- Prior catheter or surgical AF ablation.
学习计划
研究是如何设计的?
设计细节
- 主要用途:治疗
- 分配:随机化
- 介入模型:并行分配
- 屏蔽:单身的
武器和干预
参与者组/臂 |
干预/治疗 |
|---|---|
|
有源比较器:Standard power application
|
Standard power application
|
|
有源比较器:High power application
|
Radiofrequency delivery was performed in a point-by point fashion and continuously (an inter-lesion distance of 6 mm) with 50 W and 70 W and the ablation time for each point is limited to 7s and repeated if needed till the Unipolar signal modification turn to complete positive R wave.
|
研究衡量的是什么?
主要结果指标
结果测量 |
措施说明 |
大体时间 |
|---|---|---|
|
Ablation success at 6-month after the index procedure
大体时间:6 months
|
Ablation success is defined as no recurrence with no anti-arrhythmic drugs by taking history of symptoms from the patient and by Holter 48 Hours.
|
6 months
|
合作者和调查者
出版物和有用的链接
研究记录日期
研究主要日期
学习开始 (预期的)
初级完成 (预期的)
研究完成 (预期的)
研究注册日期
首次提交
首先提交符合 QC 标准的
首次发布 (实际的)
研究记录更新
最后更新发布 (实际的)
上次提交的符合 QC 标准的更新
最后验证
更多信息
此信息直接从 clinicaltrials.gov 网站检索,没有任何更改。如果您有任何更改、删除或更新研究详细信息的请求,请联系 register@clinicaltrials.gov. clinicaltrials.gov 上实施更改,我们的网站上也会自动更新.