Denne side blev automatisk oversat, og nøjagtigheden af ​​oversættelsen er ikke garanteret. Der henvises til engelsk version for en kildetekst.

Outcomes of High Power Application in Catheter Ablation of Paroxysmal Atrial Fibrillation Guided by Unipolar Signal Modification.

12. januar 2021 opdateret af: Ahmad Abdelrady Abdelsalam Farghaly, Assiut University

Pulmonary vein isolation (PVI) is the cornerstone of catheter ablation procedures in patients with paroxysmal atrial fibrillation (PAF) [1]. However, the incidence of atrial fibrillation (AF) recurrence remains high [2], mostly due to pulmonary vein (PV) reconnection [1], emphasizing the formation of transmural lesions to achieve complete conduction block along the ablation lines [3].

Previous studies have shown that elimination of the negative component of the unipolar electrogram (UP-EGM) during radiofrequency applications reflects transmural lesions. The persistence of such a negative component consistently corresponds to non-trans mural lesions [4].

Studieoversigt

Status

Ikke rekrutterer endnu

Detaljeret beskrivelse

Pulmonary vein isolation (PVI) is the cornerstone of catheter ablation procedures in patients with paroxysmal atrial fibrillation (PAF) [1]. However, the incidence of atrial fibrillation (AF) recurrence remains high [2], mostly due to pulmonary vein (PV) reconnection [1], emphasizing the formation of transmural lesions to achieve complete conduction block along the ablation lines [3].

Previous studies have shown that elimination of the negative component of the unipolar electrogram (UP-EGM) during radiofrequency applications reflects transmural lesions. The persistence of such a negative component consistently corresponds to non-trans mural lesions [4].

The high-power short duration (HPSD) RF application applies to all RF energies delivered at more than 40 W [5]. Higher the power more is the resistive heating causing wider tissue injury [5]. The lesion size with HPSD is larger in width but lesser in depth compared to lower powers with longer duration [5]. In contrast, RF applications of lower power and longer duration result in larger dissipation of RF energies deep into the tissues due to conductive heating causing tissue destruction at greater depths [6]. Hence, there is a risk of collateral tissue damage [5].

HPSD ablation has been advocated as a means to minimize the risk of collateral organ damage as the lesions are smaller in depth. However, Maintaining a high power for a constant duration in the absence of a guide may not be the right strategy [5].

Unipolar waveform modification by complete elimination of the negative component may serve as a guide for HPSD ablation [5].

Undersøgelsestype

Interventionel

Tilmelding (Forventet)

50

Fase

  • Ikke anvendelig

Deltagelseskriterier

Forskere leder efter personer, der passer til en bestemt beskrivelse, kaldet berettigelseskriterier. Nogle eksempler på disse kriterier er en persons generelle helbredstilstand eller tidligere behandlinger.

Berettigelseskriterier

Aldre berettiget til at studere

18 år til 80 år (Voksen, Ældre voksen)

Tager imod sunde frivillige

Ingen

Køn, der er berettiget til at studere

Alle

Beskrivelse

Inclusion Criteria:

  • Paroxysmal atrial fibrillation

Exclusion Criteria:

  • Age< 18 or > 80 years old,
  • Atrium (LA) diameter > 50 mm,
  • The presence of a mechanical mitral valve prosthesis,
  • Left ventricular ejection fraction < 40%,
  • Abnormal thyroid function,
  • Contraindication to anticoagulant therapy,
  • Current malignancy,
  • Prior catheter or surgical AF ablation.

Studieplan

Dette afsnit indeholder detaljer om studieplanen, herunder hvordan undersøgelsen er designet, og hvad undersøgelsen måler.

Hvordan er undersøgelsen tilrettelagt?

Design detaljer

  • Primært formål: Behandling
  • Tildeling: Randomiseret
  • Interventionel model: Parallel tildeling
  • Maskning: Enkelt

Våben og indgreb

Deltagergruppe / Arm
Intervention / Behandling
Aktiv komparator: Standard power application
Standard power application
Aktiv komparator: High power application
Radiofrequency delivery was performed in a point-by point fashion and continuously (an inter-lesion distance of 6 mm) with 50 W and 70 W and the ablation time for each point is limited to 7s and repeated if needed till the Unipolar signal modification turn to complete positive R wave.

Hvad måler undersøgelsen?

Primære resultatmål

Resultatmål
Foranstaltningsbeskrivelse
Tidsramme
Ablation success at 6-month after the index procedure
Tidsramme: 6 months
Ablation success is defined as no recurrence with no anti-arrhythmic drugs by taking history of symptoms from the patient and by Holter 48 Hours.
6 months

Samarbejdspartnere og efterforskere

Det er her, du vil finde personer og organisationer, der er involveret i denne undersøgelse.

Publikationer og nyttige links

Den person, der er ansvarlig for at indtaste oplysninger om undersøgelsen, leverer frivilligt disse publikationer. Disse kan handle om alt relateret til undersøgelsen.

Datoer for undersøgelser

Disse datoer sporer fremskridtene for indsendelser af undersøgelsesrekord og resumeresultater til ClinicalTrials.gov. Studieregistreringer og rapporterede resultater gennemgås af National Library of Medicine (NLM) for at sikre, at de opfylder specifikke kvalitetskontrolstandarder, før de offentliggøres på den offentlige hjemmeside.

Studer store datoer

Studiestart (Forventet)

20. september 2021

Primær færdiggørelse (Forventet)

1. oktober 2022

Studieafslutning (Forventet)

20. marts 2023

Datoer for studieregistrering

Først indsendt

23. juni 2020

Først indsendt, der opfyldte QC-kriterier

24. juni 2020

Først opslået (Faktiske)

25. juni 2020

Opdateringer af undersøgelsesjournaler

Sidste opdatering sendt (Faktiske)

13. januar 2021

Sidste opdatering indsendt, der opfyldte kvalitetskontrolkriterier

12. januar 2021

Sidst verificeret

1. januar 2021

Mere information

Begreber relateret til denne undersøgelse

Andre undersøgelses-id-numre

  • atrial fibrillation ablation

Plan for individuelle deltagerdata (IPD)

Planlægger du at dele individuelle deltagerdata (IPD)?

UBESLUTET

Lægemiddel- og udstyrsoplysninger, undersøgelsesdokumenter

Studerer et amerikansk FDA-reguleret lægemiddelprodukt

Ingen

Studerer et amerikansk FDA-reguleret enhedsprodukt

Ingen

Disse oplysninger blev hentet direkte fra webstedet clinicaltrials.gov uden ændringer. Hvis du har nogen anmodninger om at ændre, fjerne eller opdatere dine undersøgelsesoplysninger, bedes du kontakte register@clinicaltrials.gov. Så snart en ændring er implementeret på clinicaltrials.gov, vil denne også blive opdateret automatisk på vores hjemmeside .

Kliniske forsøg med Atrieflimren Paroxysmal

Kliniske forsøg med Standard power application

Abonner